EMG-Based Hand-Wrist Control: Study B Mirrored (PSICON-B)
EMG-Based Hand-Wrist Control: Study B: Comparison of Contralateral (Mirrored) EMG-
Studieöversikt
Status
Intervention / Behandling
Detaljerad beskrivning
Studietyp
Inskrivning (Faktisk)
Fas
- Tidig fas 1
Kontakter och platser
Studieorter
-
-
Massachusetts
-
Holliston, Massachusetts, Förenta staterna, 01746
- Liberating Technologies, Inc
-
Worcester, Massachusetts, Förenta staterna, 01609
- Worcester Polytechnic Institute
-
-
Deltagandekriterier
Urvalskriterier
Åldrar som är berättigade till studier
Tar emot friska volontärer
Kön som är behöriga för studier
Beskrivning
Inclusion Criteria:
- Limb-absent subjects: unilateral trans-radial limb absence or amputation
- Be capable of completing the requested contractions on the affected dominant side
Exclusion Criteria:
- Past injuries to the upper limbs that would limit their ability to complete the requested contractions
- Scars that would impede the use of surface electrodes
Studieplan
Hur är studien utformad?
Designdetaljer
- Primärt syfte: Grundläggande vetenskap
- Tilldelning: Icke-randomiserad
- Interventionsmodell: Sekventiell tilldelning
- Maskning: Ingen (Open Label)
Vapen och interventioner
Deltagargrupp / Arm |
Intervention / Behandling |
|---|---|
|
Experimentell: Study B: Limb-Absent Subject
Ten unilateral transradial limb-absent subjects will each participate in one, half-day experimental session.
Subjects will be seated and prepared in test apparatus seat (16 electrodes on the affected side, hand-wrist on the able side secured to load cells).
Subjects will complete the 1-DoF and 2-DoF "dynamic" (force-varying) contractions (40-s duration, 0.75 Hz bandlimited, uniform random target).
With 2 DoF contraction trials, hand Opn-Cls will always be one of the dimensions.
The subject will then be released from the cuff and their able side not further involved in the experiment.
The force feedback triangle cursor on the computer screen will be deleted such that only the target remains.
Subjects will then repeat 1-DoF and 2-DoF trials in which the affected side attempts to produce hand-wrist effort that mimic movement of the target (with no feedback provided).
|
Test apparatus acquires 16 sEMG channels, measure four DoFs of force/moment at the hand-wrist [hand open-close (Opn-Cls); wrist extension-flexion (Ext-Flx), radial-ulnar deviation (Rad-Uln) and pronation-supination (Pro-Sup)].
sEMG system used 16 custom encased bipolar electrodes.
A commercial LTI EMG amplifier (BE328) conditioned each EMG signal before A/D conversion on a PC.
A thermoplastic hand cuff secured the wrist to a six-axis load cell (AMTI, model MC3A-100) for force/moment measurement.
A separate hand-grasp one-axis load cell (Omega Engineering Inc., model LCR-150) was Velcro-secured between the fingers and the thumb, to measure power grip forces.
The PC acquired and stored the sEMG and load cell data, and commanded a triangular screen target.
The subject controlled a second triangular cursor.
Left-right movement of the cursor was controlled by wrist Ext-Flx, up-down movement by Rad-Uln deviation, cursor rotation by Pro-Sup and cursor size by hand Opn-Cls forces.
Andra namn:
|
|
Experimentell: Study B: Able-bodied Subjects
Ten able-bodied subjects, the electrodes will be mounted on the dominant arm for the EMG-force and EMG-target tracking trials.
In addition, the non-dominant arm will also be constrained and measured in a second load cell.
This load cell will not be used for feedback during the experiment, but will compare (RMS error, off-line) the dominant vs. non-dominant forces.
For EMG-target tracking, the dominant hand will remain in the wrist cuff (to prevent flailing during contractions), with the screen feedback disabled.
These subjects will repeat the trials with the electrodes moved to the non-dominant side.
EMG-force tracking will be repeated using mirrored contractions.
The three training methods (EMG-force ipsilateral, EMG-force contralateral mirrored, EMG-target on the dominant side) will be contrasted to help understand the source of errors when training with limb-absent subjects.
|
Test apparatus acquires 16 sEMG channels, measure four DoFs of force/moment at the hand-wrist [hand open-close (Opn-Cls); wrist extension-flexion (Ext-Flx), radial-ulnar deviation (Rad-Uln) and pronation-supination (Pro-Sup)].
sEMG system used 16 custom encased bipolar electrodes.
A commercial LTI EMG amplifier (BE328) conditioned each EMG signal before A/D conversion on a PC.
A thermoplastic hand cuff secured the wrist to a six-axis load cell (AMTI, model MC3A-100) for force/moment measurement.
A separate hand-grasp one-axis load cell (Omega Engineering Inc., model LCR-150) was Velcro-secured between the fingers and the thumb, to measure power grip forces.
The PC acquired and stored the sEMG and load cell data, and commanded a triangular screen target.
The subject controlled a second triangular cursor.
Left-right movement of the cursor was controlled by wrist Ext-Flx, up-down movement by Rad-Uln deviation, cursor rotation by Pro-Sup and cursor size by hand Opn-Cls forces.
Andra namn:
|
Vad mäter studien?
Primära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
EMG-Force Models
Tidsram: 1 day visit
|
Electromyogram waveform measurements (signal amplitude, frequency) will be related to force measurements (magnitude and moment) as related to the target tracking tasks. These signal-force data will be use to generate the models. The specific outcome for each subject will be the RMS error measured in the tracking tasks as the difference between the generated control signal from the user versus the prompted target signal, as measured by an EMG array. |
1 day visit
|
Samarbetspartners och utredare
Studieavstämningsdatum
Studera stora datum
Studiestart (Faktisk)
Primärt slutförande (Faktisk)
Avslutad studie (Faktisk)
Studieregistreringsdatum
Först inskickad
Först inskickad som uppfyllde QC-kriterierna
Första postat (Faktisk)
Uppdateringar av studier
Senaste uppdatering publicerad (Faktisk)
Senaste inskickade uppdateringen som uppfyllde QC-kriterierna
Senast verifierad
Mer information
Termer relaterade till denna studie
Nyckelord
Ytterligare relevanta MeSH-villkor
Andra studie-ID-nummer
- 124039
- IRB-17-155 (Annan identifierare: Worcester Polytechnic Institute)
- 5R42HD076519-03 (U.S.S. NIH-anslag/kontrakt)
Läkemedels- och apparatinformation, studiedokument
Studerar en amerikansk FDA-reglerad läkemedelsprodukt
Studerar en amerikansk FDA-reglerad produktprodukt
produkt tillverkad i och exporterad från U.S.A.
Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .