- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT04871620
Reliability of a New Pulse Contour Technique for Diagnosing an Increase in Stroke Volume During a Fluid Challenge for Hemodynamic Optimization in Patients Scheduled for High-risk Abdominal Surgery: Comparison With Transthoracic Echocardiography: COMPARE Study (COMPARE)
연구 개요
상세 설명
In European countries, day-7 mortality rate could reach 1-5. %. Emergency conditions, American Society Assessment (ASA) and major surgery were associated with a higher risk of immediate mortality. Moreover, hemodynamic instability is well known to lead to postoperative complications and a higher risk of mortality.
Since, nearly 30 years, optimization of hemodynamic conditions, especially via an optimization of the fluid administration has been shown to improve immediate and long-term patient outcome. This strategy is currently widely accepted and recommended in medium and high-risk surgery. Therefore, optimizing cardiac output and one of its surrogate is proposed over intraoperative surgery. For assessing the cardiac output or the indexed stroke volume, esophageal Doppler and pulse contour technique have been proposed and have shown that they could improve patient outcome.
However, the reliability of esophageal Doppler, pulse contour and non-invasive techniques assessing cardiac output and its ability to detect a change in the initial value of CO have been challenged. Initially, the reliability of a technique for measuring CO has been described by using a correlation coefficient and by building Bland & Altman diagram. However, searching a correlation between two different techniques measuring the same parameter will lead to a correlation. In the same, Bland & Altman technique shows the mean difference between measurements of the same parameters; However, demonstrating a good reliability should be shown by a narrow limit of agreement with no definition of the narrowness. Indeed, a value of cardiac index (CI) = 3 l/min/m2 with a mean difference of 0 +/- 1.1 /min/m2 by Bland & Altman technique mean that the CI value could be within 1 and 5 l/min/m2 that could lead to different treatment such as fluid challenge, vasopressor or inotrope infusion.
An interesting method for comparing two techniques measuring the same parameter could be to challenge one technique versus the other one in decision-making. Applying this method to techniques measuring CO, we could search for the interest of a new technique for diagnosing an increase in CO after a fluid challenge for optimizing cardiac preload and hemodynamic status. Esophageal Doppler is classically recommended for optimizing hemodynamic patient in high-risk surgery.
A new device using pulse contour technology has been available since a few years. Therefore, the present study aims at assessing the ability of this device for diagnosing an increase in CO > 15% during patient hemodynamic optimization by fluid challenge.
연구 유형
등록 (실제)
연락처 및 위치
연구 장소
-
-
-
Nîmes, 프랑스, 30029
- CHU de Nîmes
-
-
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
샘플링 방법
연구 인구
설명
Inclusion Criteria:
- Adult patient ASA status 1-3 who were orally informed and did refuse to participate.
- Patient in whom general anesthesia with tracheal intubation were planned.
- Patient in whom an arterial catheter and a monitoring of cardiac output by esophageal Doppler were indicated for hemodynamic optimization
- Patient with cardiac sinusal mode
Exclusion Criteria:
- Patient < 18-year-old
- Cardiac arrythmia
- Patient with anomaly in oro-pharyngo-esophageal tractus
- Patients with hemostasis anomaly (PT < 30%, platelets < 50 000 elements/mm3)
- Patient in whom the cardiac output monitoring or measurement was not possible by Esophageal Doppler or echography
- Patients in whom cardiac arrythmia occurred during the procedure of hemodynamic optimization.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 관찰 모델: 보병대
- 시간 관점: 유망한
코호트 및 개입
그룹/코호트 |
개입 / 치료 |
|---|---|
|
Hemodynamic optimization
Patients scheduled for intermediate and high-risk abdominal surgery were eligible to participate
|
The stroke volume will be measured before and after 15 minutes fluid challenge with crystalloids
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Ability of pulse contour for diagnosing a >15% increase in stroke volume
기간: 15 minutes
|
Ability of pulse contour for diagnosing a >15% increase in stroke volume
|
15 minutes
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Comparison with the ability of other techniques
기간: 15 minutes
|
Comparison with the ability of other techniques (Esophagial Doppler, other pulse contour techniques for diagnosing a >15% SV increase)
|
15 minutes
|
|
Ability for predicting a >15% SV increase
기간: 15 minutes
|
Ability of Esophagial Doppler and Pulse contour techniques for predicting a >15% SV increase after rapid infusion of 100ml cristalloid over one minute (mini-fluid challenge)
|
15 minutes
|
공동 작업자 및 조사자
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
기본 완료 (실제)
연구 완료 (실제)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
추가 관련 MeSH 약관
기타 연구 ID 번호
- IRB 15.11.02
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .