Reliability of a New Pulse Contour Technique for Diagnosing an Increase in Stroke Volume During a Fluid Challenge for Hemodynamic Optimization in Patients Scheduled for High-risk Abdominal Surgery: Comparison With Transthoracic Echocardiography: COMPARE Study (COMPARE)
研究概览
详细说明
In European countries, day-7 mortality rate could reach 1-5. %. Emergency conditions, American Society Assessment (ASA) and major surgery were associated with a higher risk of immediate mortality. Moreover, hemodynamic instability is well known to lead to postoperative complications and a higher risk of mortality.
Since, nearly 30 years, optimization of hemodynamic conditions, especially via an optimization of the fluid administration has been shown to improve immediate and long-term patient outcome. This strategy is currently widely accepted and recommended in medium and high-risk surgery. Therefore, optimizing cardiac output and one of its surrogate is proposed over intraoperative surgery. For assessing the cardiac output or the indexed stroke volume, esophageal Doppler and pulse contour technique have been proposed and have shown that they could improve patient outcome.
However, the reliability of esophageal Doppler, pulse contour and non-invasive techniques assessing cardiac output and its ability to detect a change in the initial value of CO have been challenged. Initially, the reliability of a technique for measuring CO has been described by using a correlation coefficient and by building Bland & Altman diagram. However, searching a correlation between two different techniques measuring the same parameter will lead to a correlation. In the same, Bland & Altman technique shows the mean difference between measurements of the same parameters; However, demonstrating a good reliability should be shown by a narrow limit of agreement with no definition of the narrowness. Indeed, a value of cardiac index (CI) = 3 l/min/m2 with a mean difference of 0 +/- 1.1 /min/m2 by Bland & Altman technique mean that the CI value could be within 1 and 5 l/min/m2 that could lead to different treatment such as fluid challenge, vasopressor or inotrope infusion.
An interesting method for comparing two techniques measuring the same parameter could be to challenge one technique versus the other one in decision-making. Applying this method to techniques measuring CO, we could search for the interest of a new technique for diagnosing an increase in CO after a fluid challenge for optimizing cardiac preload and hemodynamic status. Esophageal Doppler is classically recommended for optimizing hemodynamic patient in high-risk surgery.
A new device using pulse contour technology has been available since a few years. Therefore, the present study aims at assessing the ability of this device for diagnosing an increase in CO > 15% during patient hemodynamic optimization by fluid challenge.
研究类型
注册 (实际的)
联系人和位置
学习地点
-
-
-
Nîmes、法国、30029
- CHU de Nîmes
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
取样方法
研究人群
描述
Inclusion Criteria:
- Adult patient ASA status 1-3 who were orally informed and did refuse to participate.
- Patient in whom general anesthesia with tracheal intubation were planned.
- Patient in whom an arterial catheter and a monitoring of cardiac output by esophageal Doppler were indicated for hemodynamic optimization
- Patient with cardiac sinusal mode
Exclusion Criteria:
- Patient < 18-year-old
- Cardiac arrythmia
- Patient with anomaly in oro-pharyngo-esophageal tractus
- Patients with hemostasis anomaly (PT < 30%, platelets < 50 000 elements/mm3)
- Patient in whom the cardiac output monitoring or measurement was not possible by Esophageal Doppler or echography
- Patients in whom cardiac arrythmia occurred during the procedure of hemodynamic optimization.
学习计划
研究是如何设计的?
设计细节
- 观测模型:队列
- 时间观点:预期
队列和干预
团体/队列 |
干预/治疗 |
|---|---|
|
Hemodynamic optimization
Patients scheduled for intermediate and high-risk abdominal surgery were eligible to participate
|
The stroke volume will be measured before and after 15 minutes fluid challenge with crystalloids
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Ability of pulse contour for diagnosing a >15% increase in stroke volume
大体时间:15 minutes
|
Ability of pulse contour for diagnosing a >15% increase in stroke volume
|
15 minutes
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Comparison with the ability of other techniques
大体时间:15 minutes
|
Comparison with the ability of other techniques (Esophagial Doppler, other pulse contour techniques for diagnosing a >15% SV increase)
|
15 minutes
|
|
Ability for predicting a >15% SV increase
大体时间:15 minutes
|
Ability of Esophagial Doppler and Pulse contour techniques for predicting a >15% SV increase after rapid infusion of 100ml cristalloid over one minute (mini-fluid challenge)
|
15 minutes
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他相关的 MeSH 术语
其他研究编号
- IRB 15.11.02
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.