Reliability of a New Pulse Contour Technique for Diagnosing an Increase in Stroke Volume During a Fluid Challenge for Hemodynamic Optimization in Patients Scheduled for High-risk Abdominal Surgery: Comparison With Transthoracic Echocardiography: COMPARE Study (COMPARE)

16. Juni 2026 aktualisiert von: Centre Hospitalier Universitaire de Nīmes
The present study aims at assessing the ability of a new pulse contour device for diagnosing a >15% stroke volume (SV) increase during patient hemodynamic optimization by fluid challenge in high risk abdominal surgery.

Studienübersicht

Status

Abgeschlossen

Detaillierte Beschreibung

In European countries, day-7 mortality rate could reach 1-5. %. Emergency conditions, American Society Assessment (ASA) and major surgery were associated with a higher risk of immediate mortality. Moreover, hemodynamic instability is well known to lead to postoperative complications and a higher risk of mortality.

Since, nearly 30 years, optimization of hemodynamic conditions, especially via an optimization of the fluid administration has been shown to improve immediate and long-term patient outcome. This strategy is currently widely accepted and recommended in medium and high-risk surgery. Therefore, optimizing cardiac output and one of its surrogate is proposed over intraoperative surgery. For assessing the cardiac output or the indexed stroke volume, esophageal Doppler and pulse contour technique have been proposed and have shown that they could improve patient outcome.

However, the reliability of esophageal Doppler, pulse contour and non-invasive techniques assessing cardiac output and its ability to detect a change in the initial value of CO have been challenged. Initially, the reliability of a technique for measuring CO has been described by using a correlation coefficient and by building Bland & Altman diagram. However, searching a correlation between two different techniques measuring the same parameter will lead to a correlation. In the same, Bland & Altman technique shows the mean difference between measurements of the same parameters; However, demonstrating a good reliability should be shown by a narrow limit of agreement with no definition of the narrowness. Indeed, a value of cardiac index (CI) = 3 l/min/m2 with a mean difference of 0 +/- 1.1 /min/m2 by Bland & Altman technique mean that the CI value could be within 1 and 5 l/min/m2 that could lead to different treatment such as fluid challenge, vasopressor or inotrope infusion.

An interesting method for comparing two techniques measuring the same parameter could be to challenge one technique versus the other one in decision-making. Applying this method to techniques measuring CO, we could search for the interest of a new technique for diagnosing an increase in CO after a fluid challenge for optimizing cardiac preload and hemodynamic status. Esophageal Doppler is classically recommended for optimizing hemodynamic patient in high-risk surgery.

A new device using pulse contour technology has been available since a few years. Therefore, the present study aims at assessing the ability of this device for diagnosing an increase in CO > 15% during patient hemodynamic optimization by fluid challenge.

Studientyp

Beobachtungs

Einschreibung (Tatsächlich)

100

Kontakte und Standorte

Dieser Abschnitt enthält die Kontaktdaten derjenigen, die die Studie durchführen, und Informationen darüber, wo diese Studie durchgeführt wird.

Studienorte

      • Nîmes, Frankreich, 30029
        • CHU de Nîmes

Teilnahmekriterien

Forscher suchen nach Personen, die einer bestimmten Beschreibung entsprechen, die als Auswahlkriterien bezeichnet werden. Einige Beispiele für diese Kriterien sind der allgemeine Gesundheitszustand einer Person oder frühere Behandlungen.

Zulassungskriterien

Studienberechtigtes Alter

18 Jahre und älter (Erwachsene, Älterer Erwachsener)

Akzeptiert gesunde Freiwillige

Nein

Probenahmeverfahren

Wahrscheinlichkeitsstichprobe

Studienpopulation

Patients scheduled for intermediate and high-risk abdominal surgery were eligible to participate

Beschreibung

Inclusion Criteria:

  • Adult patient ASA status 1-3 who were orally informed and did refuse to participate.
  • Patient in whom general anesthesia with tracheal intubation were planned.
  • Patient in whom an arterial catheter and a monitoring of cardiac output by esophageal Doppler were indicated for hemodynamic optimization
  • Patient with cardiac sinusal mode

Exclusion Criteria:

  • Patient < 18-year-old
  • Cardiac arrythmia
  • Patient with anomaly in oro-pharyngo-esophageal tractus
  • Patients with hemostasis anomaly (PT < 30%, platelets < 50 000 elements/mm3)
  • Patient in whom the cardiac output monitoring or measurement was not possible by Esophageal Doppler or echography
  • Patients in whom cardiac arrythmia occurred during the procedure of hemodynamic optimization.

Studienplan

Dieser Abschnitt enthält Einzelheiten zum Studienplan, einschließlich des Studiendesigns und der Messung der Studieninhalte.

Wie ist die Studie aufgebaut?

Designdetails

  • Beobachtungsmodelle: Kohorte
  • Zeitperspektiven: Interessent

Kohorten und Interventionen

Gruppe / Kohorte
Intervention / Behandlung
Hemodynamic optimization
Patients scheduled for intermediate and high-risk abdominal surgery were eligible to participate
The stroke volume will be measured before and after 15 minutes fluid challenge with crystalloids

Was misst die Studie?

Primäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Ability of pulse contour for diagnosing a >15% increase in stroke volume
Zeitfenster: 15 minutes
Ability of pulse contour for diagnosing a >15% increase in stroke volume
15 minutes

Sekundäre Ergebnismessungen

Ergebnis Maßnahme
Maßnahmenbeschreibung
Zeitfenster
Comparison with the ability of other techniques
Zeitfenster: 15 minutes
Comparison with the ability of other techniques (Esophagial Doppler, other pulse contour techniques for diagnosing a >15% SV increase)
15 minutes
Ability for predicting a >15% SV increase
Zeitfenster: 15 minutes
Ability of Esophagial Doppler and Pulse contour techniques for predicting a >15% SV increase after rapid infusion of 100ml cristalloid over one minute (mini-fluid challenge)
15 minutes

Mitarbeiter und Ermittler

Hier finden Sie Personen und Organisationen, die an dieser Studie beteiligt sind.

Studienaufzeichnungsdaten

Diese Daten verfolgen den Fortschritt der Übermittlung von Studienaufzeichnungen und zusammenfassenden Ergebnissen an ClinicalTrials.gov. Studienaufzeichnungen und gemeldete Ergebnisse werden von der National Library of Medicine (NLM) überprüft, um sicherzustellen, dass sie bestimmten Qualitätskontrollstandards entsprechen, bevor sie auf der öffentlichen Website veröffentlicht werden.

Haupttermine studieren

Studienbeginn (Tatsächlich)

12. April 2016

Primärer Abschluss (Tatsächlich)

8. Januar 2024

Studienabschluss (Tatsächlich)

8. Januar 2024

Studienanmeldedaten

Zuerst eingereicht

29. April 2021

Zuerst eingereicht, das die QC-Kriterien erfüllt hat

29. April 2021

Zuerst gepostet (Tatsächlich)

4. Mai 2021

Studienaufzeichnungsaktualisierungen

Letztes Update gepostet (Tatsächlich)

18. Juni 2026

Letztes eingereichtes Update, das die QC-Kriterien erfüllt

16. Juni 2026

Zuletzt verifiziert

1. Juni 2026

Mehr Informationen

Begriffe im Zusammenhang mit dieser Studie

Plan für individuelle Teilnehmerdaten (IPD)

Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?

NEIN

Arzneimittel- und Geräteinformationen, Studienunterlagen

Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt

Nein

Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt

Nein

Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .

Abonnieren