- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT07642128
Retention of Dome and Flat Magnetic Attachments in Mandibular Implant Overdentures Randomized Controlled Clinical Trial
Effect of Two Forms of Magnetic Attachments on Retention of Implant Retained Mandibular Over-Dentures Randomized Controlled Clinical Trial
연구 개요
상세 설명
Complete edentulism of the mandible is frequently associated with compromised denture retention and stability, which may negatively affect mastication, comfort, and patient satisfaction. Mandibular implant-supported overdentures retained by magnetic attachments have been introduced as a reliable treatment option to improve prosthesis retention and function.
Different magnetic attachment designs are available, including flat and dome-shaped configurations. The geometry of magnetic attachments may influence retentive behavior, stress distribution, and overdenture stability during function. However, clinical evidence comparing the retention performance of these attachment designs remains limited.
This randomized clinical trial will include 14 completely edentulous patients aged 50-65 years. All participants will receive two implants placed in the canine regions of the mandible using a fully guided surgical protocol. After a 3-month healing period, patients will be randomly allocated into two equal groups according to the magnetic attachment design used. Group I will receive flat magnetic attachments, while Group II will receive dome-shaped magnetic attachments.
The primary outcome measure will be overdenture retention evaluated using a digital force gauge. Retention measurements will be performed at the time of overdenture loading (baseline), after 3 months of functional use, and after 6 months of functional use. The results will be used to determine whether magnetic attachment design influences the retention of mandibular implant-supported overdentures.
연구 유형
등록 (실제)
단계
- 해당 없음
연락처 및 위치
연구 장소
-
-
-
Cairo, 이집트
- Faculty of Dentistry, Ain Shams University
-
-
참여기준
자격 기준
공부할 수 있는 나이
- 성인
- 고령자
건강한 자원 봉사자를 받아들입니다
설명
Inclusion Criteria:
- Completely edentulous mandible for at least 6 months.
- Age between 50 and 65 years.
- Adequate interforaminal bone volume for placement of two implants in the mandibular canine regions.
- Angle Class I maxillomandibular relationship.
- Medically fit patients capable of undergoing implant surgery.
- Ability and willingness to comply with study visits and follow-up procedures.
- Signed informed consent.
Exclusion Criteria:
- Uncontrolled systemic diseases that may contraindicate implant surgery or affect osseointegration.
- Uncontrolled diabetes mellitus.
- Osteoporosis or metabolic bone disorders affecting implant healing.
- Previous head and neck radiotherapy.
- Presence of oral lesions or untreated oral pathology.
- Temporomandibular joint disorders.
- Parafunctional habits such as bruxism.
- Inability to comply with study protocol or follow-up schedule.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 치료
- 할당: 무작위
- 중재 모델: 병렬 할당
- 마스킹: 없음(오픈 라벨)
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
실험적: Flat Magnetic Attachment Group
Participants received mandibular implant-supported overdentures retained by flat magnetic attachments.
Two Dentium SuperLine implants were placed in the canine regions of the mandible, and flat magnetic attachments (MKP5530 keeper with MGT5520 magnetic assembly) were used for overdenture retention.
|
Flat magnetic attachment system used for retention of mandibular implant-supported overdentures.
The system consisted of a Dentium MKP5530 keeper and MGT5520 magnetic assembly with a manufacturer-reported retentive force of 700 gf.
다른 이름들:
|
|
실험적: Dome Magnetic Attachment Group
Participants received mandibular implant-supported overdentures retained by dome-shaped magnetic attachments.
Two Dentium SuperLine implants were placed in the canine regions of the mandible, and dome magnetic attachments (MKP5530D keeper with MGT5520D magnetic assembly) were used for overdenture retention.
|
Dome-shaped magnetic attachment system used for retention of mandibular implant-supported overdentures.
The system consisted of a Dentium MKP5530D keeper and MGT5520D magnetic assembly with a manufacturer-reported retentive force of 700 gf.
다른 이름들:
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Overdenture Retention Force
기간: Baseline, 3 months, and 6 months after overdenture loading
|
Retention force of mandibular implant-supported overdentures retained by flat and dome-shaped magnetic attachments, measured in Newtons (N) using a digital force gauge during vertical dislodgement.
|
Baseline, 3 months, and 6 months after overdenture loading
|
공동 작업자 및 조사자
수사관
- 연구 책임자: sawsan maged, Assoc. Prof., Faculty of Dentistry, Ain Shams University
간행물 및 유용한 링크
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
기본 완료 (실제)
연구 완료 (실제)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
키워드
기타 연구 ID 번호
- magnetic attachments
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .
Flat Magnetic Attachment에 대한 임상 시험
-
Children's Hospital of PhiladelphiaUniversity of Pennsylvania완전한