Retention of Dome and Flat Magnetic Attachments in Mandibular Implant Overdentures Randomized Controlled Clinical Trial
Effect of Two Forms of Magnetic Attachments on Retention of Implant Retained Mandibular Over-Dentures Randomized Controlled Clinical Trial
Studie Overzicht
Toestand
Interventie / Behandeling
Gedetailleerde beschrijving
Complete edentulism of the mandible is frequently associated with compromised denture retention and stability, which may negatively affect mastication, comfort, and patient satisfaction. Mandibular implant-supported overdentures retained by magnetic attachments have been introduced as a reliable treatment option to improve prosthesis retention and function.
Different magnetic attachment designs are available, including flat and dome-shaped configurations. The geometry of magnetic attachments may influence retentive behavior, stress distribution, and overdenture stability during function. However, clinical evidence comparing the retention performance of these attachment designs remains limited.
This randomized clinical trial will include 14 completely edentulous patients aged 50-65 years. All participants will receive two implants placed in the canine regions of the mandible using a fully guided surgical protocol. After a 3-month healing period, patients will be randomly allocated into two equal groups according to the magnetic attachment design used. Group I will receive flat magnetic attachments, while Group II will receive dome-shaped magnetic attachments.
The primary outcome measure will be overdenture retention evaluated using a digital force gauge. Retention measurements will be performed at the time of overdenture loading (baseline), after 3 months of functional use, and after 6 months of functional use. The results will be used to determine whether magnetic attachment design influences the retention of mandibular implant-supported overdentures.
Studietype
Inschrijving (Werkelijk)
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
-
Cairo, Egypte
- Faculty of Dentistry, Ain Shams University
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Volwassen
- Oudere volwassene
Accepteert gezonde vrijwilligers
Beschrijving
Inclusion Criteria:
- Completely edentulous mandible for at least 6 months.
- Age between 50 and 65 years.
- Adequate interforaminal bone volume for placement of two implants in the mandibular canine regions.
- Angle Class I maxillomandibular relationship.
- Medically fit patients capable of undergoing implant surgery.
- Ability and willingness to comply with study visits and follow-up procedures.
- Signed informed consent.
Exclusion Criteria:
- Uncontrolled systemic diseases that may contraindicate implant surgery or affect osseointegration.
- Uncontrolled diabetes mellitus.
- Osteoporosis or metabolic bone disorders affecting implant healing.
- Previous head and neck radiotherapy.
- Presence of oral lesions or untreated oral pathology.
- Temporomandibular joint disorders.
- Parafunctional habits such as bruxism.
- Inability to comply with study protocol or follow-up schedule.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Behandeling
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: Flat Magnetic Attachment Group
Participants received mandibular implant-supported overdentures retained by flat magnetic attachments.
Two Dentium SuperLine implants were placed in the canine regions of the mandible, and flat magnetic attachments (MKP5530 keeper with MGT5520 magnetic assembly) were used for overdenture retention.
|
Flat magnetic attachment system used for retention of mandibular implant-supported overdentures.
The system consisted of a Dentium MKP5530 keeper and MGT5520 magnetic assembly with a manufacturer-reported retentive force of 700 gf.
Andere namen:
|
|
Experimenteel: Dome Magnetic Attachment Group
Participants received mandibular implant-supported overdentures retained by dome-shaped magnetic attachments.
Two Dentium SuperLine implants were placed in the canine regions of the mandible, and dome magnetic attachments (MKP5530D keeper with MGT5520D magnetic assembly) were used for overdenture retention.
|
Dome-shaped magnetic attachment system used for retention of mandibular implant-supported overdentures.
The system consisted of a Dentium MKP5530D keeper and MGT5520D magnetic assembly with a manufacturer-reported retentive force of 700 gf.
Andere namen:
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Overdenture Retention Force
Tijdsspanne: Baseline, 3 months, and 6 months after overdenture loading
|
Retention force of mandibular implant-supported overdentures retained by flat and dome-shaped magnetic attachments, measured in Newtons (N) using a digital force gauge during vertical dislodgement.
|
Baseline, 3 months, and 6 months after overdenture loading
|
Medewerkers en onderzoekers
Sponsor
Onderzoekers
- Studie directeur: sawsan maged, Assoc. Prof., Faculty of Dentistry, Ain Shams University
Publicaties en nuttige links
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Andere studie-ID-nummers
- magnetic attachments
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .