Accuracy of Complete-Arch Implant Photogrammetry

2026년 6월 7일 업데이트: Mohammed El-Sawy, Menoufia University

Accuracy of Complete-arch Implant Scans Obtained Using Intraoral Photogrammetry and a Mobile-phone Based Photogrammetry.

This prospective comparative clinical study evaluated the accuracy and chairside time of complete-arch implant scans obtained using an intraoral photogrammetry system and a mobile-phone-based photogrammetry system in edentulous patients rehabilitated with complete-arch implant-supported prostheses. Implant positions recorded by each system were compared with a reference dataset to assess linear and angular discrepancies. The chairside time required for data acquisition was also measured. The study aimed to determine whether mobile-phone-based photogrammetry can provide clinically acceptable accuracy comparable to that of intraoral photogrammetry while improving clinical efficiency. The findings may help clinicians select appropriate digital impression techniques for complete-arch implant rehabilitation.

연구 개요

상세 설명

Accurate recording of implant positions is essential for the passive fit and long-term success of complete-arch implant-supported prostheses. Photogrammetry-based technologies have emerged as promising alternatives to conventional digital impression techniques for capturing implant positions with high accuracy. While intraoral photogrammetry systems have demonstrated favorable results, the clinical performance of recently introduced mobile-phone-based photogrammetry systems remains insufficiently investigated.

This prospective comparative clinical study aims to evaluate the accuracy and chairside time of complete-arch implant scans obtained using an intraoral photogrammetry system and a mobile-phone-based photogrammetry system in edentulous patients restored with complete-arch implant-supported prostheses. Each participant will undergo implant scanning using both systems according to the manufacturers' recommendations. The resulting digital datasets will be compared with a reference dataset to determine scan accuracy.

The primary outcome measures will be linear and angular discrepancies between the implant positions captured by each photogrammetry system and the reference dataset. Secondary outcome measures will include the chairside time required for scan acquisition. Statistical analyses will be performed to compare the accuracy and efficiency of the evaluated systems.

연구 유형

관찰

등록 (추정된)

42

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 연락처

연구 장소

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

  • 성인

건강한 자원 봉사자를 받아들입니다

해당 없음

샘플링 방법

비확률 샘플

연구 인구

The study population will consist of adult completely edentulous patients who have been rehabilitated with implant-supported complete-arch prostheses. Eligible participants will present with a fully edentulous arch restored by at least four osseointegrated dental implants and will be recruited from patients seeking prosthodontic treatment and follow-up care at the study center. All participants will undergo complete-arch implant scanning using both an intraoral photogrammetry system and a mobile-phone-based photogrammetry system for comparative evaluation of scan accuracy and chairside acquisition time. Only patients meeting the predefined inclusion criteria and providing written informed consent will be enrolled.

설명

Inclusion Criteria:

  • Adults aged 18 years or older.
  • Completely edentulous patients rehabilitated with implant-supported complete-arch prostheses.
  • Presence of at least four osseointegrated implants in the edentulous arch.
  • Patients able to undergo digital implant scanning procedures.
  • Patients willing to participate and provide written informed consent.

Exclusion Criteria:

  • Patients with unstable or failed implants.
  • Presence of peri-implant disease, active oral infection, or significant soft-tissue inflammation around the implants.
  • Inadequate access for placement of photogrammetry scan bodies or markers.
  • Patients with conditions that prevent proper scanning procedures (e.g., inability to maintain mouth opening or remain still during data acquisition).
  • Patients requiring immediate implant placement or immediate loading protocols.
  • Patients unwilling or unable to provide informed consent.
  • Incomplete clinical records or inability to complete all study procedures.

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

코호트 및 개입

그룹/코호트
개입 / 치료
Intraoral Photogrammetry (IPG)
Participants will undergo complete-arch implant scanning using an intraoral photogrammetry system (IPF Elite, Shining 3D). Implant positions will be digitally recorded according to the manufacturer's instructions. Linear and angular discrepancies relative to the reference dataset, as well as chairside scanning time, will be evaluated.
A photogrammetry-based digital impression system used to capture the three-dimensional positions of implants in complete-arch rehabilitations. The system records implant locations through specialized scan bodies and generates a digital dataset for subsequent accuracy analysis.
다른 이름들:
  • IPF Elite; Shining 3D; Intraoral Photogrammetry System
Mobile-Phone-Based Photogrammetry
Participants will undergo complete-arch implant scanning using a mobile-phone-based photogrammetry system (T-Marker). Implant positions will be digitally recorded according to the manufacturer's instructions. Linear and angular discrepancies relative to the reference dataset, as well as chairside scanning time, will be evaluated.
A smartphone-assisted photogrammetry system used to capture the three-dimensional positions of implants in complete-arch rehabilitations. The system acquires photographic data through coded markers and generates a digital dataset for subsequent accuracy analysis.
다른 이름들:
  • T-Marker; Extraoral Photogrammetry; Mobile-Phone-Based Photogrammetry System

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Linear Discrepancy of Complete-Arch Implant Scans
기간: Immediately after scan acquisition and digital analysis (same study visit).
Assessment of the linear deviation (μm) between implant positions captured using intraoral photogrammetry and mobile-phone-based photogrammetry systems and those recorded in the reference dataset. Lower values indicate greater accuracy.
Immediately after scan acquisition and digital analysis (same study visit).

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

수사관

  • 수석 연구원: Mohammed A. El-Sawy, PhD, Menoufia University

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2026년 1월 1일

기본 완료 (추정된)

2026년 8월 1일

연구 완료 (추정된)

2026년 8월 1일

연구 등록 날짜

최초 제출

2026년 6월 7일

QC 기준을 충족하는 최초 제출

2026년 6월 7일

처음 게시됨 (실제)

2026년 6월 11일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 6월 11일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 6월 7일

마지막으로 확인됨

2026년 6월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • ADMNF-000026

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

아니요

IPD 계획 설명

Up on resonable request from the corresponding author

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니