Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Accuracy of Complete-Arch Implant Photogrammetry

7 de junho de 2026 atualizado por: Mohammed El-Sawy, Menoufia University

Accuracy of Complete-arch Implant Scans Obtained Using Intraoral Photogrammetry and a Mobile-phone Based Photogrammetry.

This prospective comparative clinical study evaluated the accuracy and chairside time of complete-arch implant scans obtained using an intraoral photogrammetry system and a mobile-phone-based photogrammetry system in edentulous patients rehabilitated with complete-arch implant-supported prostheses. Implant positions recorded by each system were compared with a reference dataset to assess linear and angular discrepancies. The chairside time required for data acquisition was also measured. The study aimed to determine whether mobile-phone-based photogrammetry can provide clinically acceptable accuracy comparable to that of intraoral photogrammetry while improving clinical efficiency. The findings may help clinicians select appropriate digital impression techniques for complete-arch implant rehabilitation.

Visão geral do estudo

Descrição detalhada

Accurate recording of implant positions is essential for the passive fit and long-term success of complete-arch implant-supported prostheses. Photogrammetry-based technologies have emerged as promising alternatives to conventional digital impression techniques for capturing implant positions with high accuracy. While intraoral photogrammetry systems have demonstrated favorable results, the clinical performance of recently introduced mobile-phone-based photogrammetry systems remains insufficiently investigated.

This prospective comparative clinical study aims to evaluate the accuracy and chairside time of complete-arch implant scans obtained using an intraoral photogrammetry system and a mobile-phone-based photogrammetry system in edentulous patients restored with complete-arch implant-supported prostheses. Each participant will undergo implant scanning using both systems according to the manufacturers' recommendations. The resulting digital datasets will be compared with a reference dataset to determine scan accuracy.

The primary outcome measures will be linear and angular discrepancies between the implant positions captured by each photogrammetry system and the reference dataset. Secondary outcome measures will include the chairside time required for scan acquisition. Statistical analyses will be performed to compare the accuracy and efficiency of the evaluated systems.

Tipo de estudo

Observacional

Inscrição (Estimado)

42

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

Locais de estudo

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

  • Adulto

Aceita Voluntários Saudáveis

N/D

Método de amostragem

Amostra Não Probabilística

População do estudo

The study population will consist of adult completely edentulous patients who have been rehabilitated with implant-supported complete-arch prostheses. Eligible participants will present with a fully edentulous arch restored by at least four osseointegrated dental implants and will be recruited from patients seeking prosthodontic treatment and follow-up care at the study center. All participants will undergo complete-arch implant scanning using both an intraoral photogrammetry system and a mobile-phone-based photogrammetry system for comparative evaluation of scan accuracy and chairside acquisition time. Only patients meeting the predefined inclusion criteria and providing written informed consent will be enrolled.

Descrição

Inclusion Criteria:

  • Adults aged 18 years or older.
  • Completely edentulous patients rehabilitated with implant-supported complete-arch prostheses.
  • Presence of at least four osseointegrated implants in the edentulous arch.
  • Patients able to undergo digital implant scanning procedures.
  • Patients willing to participate and provide written informed consent.

Exclusion Criteria:

  • Patients with unstable or failed implants.
  • Presence of peri-implant disease, active oral infection, or significant soft-tissue inflammation around the implants.
  • Inadequate access for placement of photogrammetry scan bodies or markers.
  • Patients with conditions that prevent proper scanning procedures (e.g., inability to maintain mouth opening or remain still during data acquisition).
  • Patients requiring immediate implant placement or immediate loading protocols.
  • Patients unwilling or unable to provide informed consent.
  • Incomplete clinical records or inability to complete all study procedures.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

Coortes e Intervenções

Grupo / Coorte
Intervenção / Tratamento
Intraoral Photogrammetry (IPG)
Participants will undergo complete-arch implant scanning using an intraoral photogrammetry system (IPF Elite, Shining 3D). Implant positions will be digitally recorded according to the manufacturer's instructions. Linear and angular discrepancies relative to the reference dataset, as well as chairside scanning time, will be evaluated.
A photogrammetry-based digital impression system used to capture the three-dimensional positions of implants in complete-arch rehabilitations. The system records implant locations through specialized scan bodies and generates a digital dataset for subsequent accuracy analysis.
Outros nomes:
  • IPF Elite; Shining 3D; Intraoral Photogrammetry System
Mobile-Phone-Based Photogrammetry
Participants will undergo complete-arch implant scanning using a mobile-phone-based photogrammetry system (T-Marker). Implant positions will be digitally recorded according to the manufacturer's instructions. Linear and angular discrepancies relative to the reference dataset, as well as chairside scanning time, will be evaluated.
A smartphone-assisted photogrammetry system used to capture the three-dimensional positions of implants in complete-arch rehabilitations. The system acquires photographic data through coded markers and generates a digital dataset for subsequent accuracy analysis.
Outros nomes:
  • T-Marker; Extraoral Photogrammetry; Mobile-Phone-Based Photogrammetry System

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Linear Discrepancy of Complete-Arch Implant Scans
Prazo: Immediately after scan acquisition and digital analysis (same study visit).
Assessment of the linear deviation (μm) between implant positions captured using intraoral photogrammetry and mobile-phone-based photogrammetry systems and those recorded in the reference dataset. Lower values indicate greater accuracy.
Immediately after scan acquisition and digital analysis (same study visit).

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Colaboradores

Investigadores

  • Investigador principal: Mohammed A. El-Sawy, PhD, Menoufia University

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

1 de janeiro de 2026

Conclusão Primária (Estimado)

1 de agosto de 2026

Conclusão do estudo (Estimado)

1 de agosto de 2026

Datas de inscrição no estudo

Enviado pela primeira vez

7 de junho de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

7 de junho de 2026

Primeira postagem (Real)

11 de junho de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

11 de junho de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

7 de junho de 2026

Última verificação

1 de junho de 2026

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • ADMNF-000026

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Descrição do plano IPD

Up on resonable request from the corresponding author

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Ensaios clínicos em Intraoral Photogrammetry (IPG)

Se inscrever