Accuracy of Complete-Arch Implant Photogrammetry

2026. szeptember 13. frissítette: Mohammed El-Sawy, Menoufia University

Accuracy of Complete-arch Implant Scans Obtained Using Intraoral Photogrammetry and a Mobile-phone Based Photogrammetry.

This prospective comparative clinical study evaluated the accuracy and chairside time of complete-arch implant scans obtained using an intraoral photogrammetry system and a mobile-phone-based photogrammetry system in edentulous patients rehabilitated with complete-arch implant-supported prostheses. Implant positions recorded by each system were compared with a reference dataset to assess linear and angular discrepancies. The chairside time required for data acquisition was also measured. The study aimed to determine whether mobile-phone-based photogrammetry can provide clinically acceptable accuracy comparable to that of intraoral photogrammetry while improving clinical efficiency. The findings may help clinicians select appropriate digital impression techniques for complete-arch implant rehabilitation.

A tanulmány áttekintése

Részletes leírás

Accurate recording of implant positions is essential for the passive fit and long-term success of complete-arch implant-supported prostheses. Photogrammetry-based technologies have emerged as promising alternatives to conventional digital impression techniques for capturing implant positions with high accuracy. While intraoral photogrammetry systems have demonstrated favorable results, the clinical performance of recently introduced mobile-phone-based photogrammetry systems remains insufficiently investigated.

This prospective comparative clinical study aims to evaluate the accuracy and chairside time of complete-arch implant scans obtained using an intraoral photogrammetry system and a mobile-phone-based photogrammetry system in edentulous patients restored with complete-arch implant-supported prostheses. Each participant will undergo implant scanning using both systems according to the manufacturers' recommendations. The resulting digital datasets will be compared with a reference dataset to determine scan accuracy.

The primary outcome measures will be linear and angular discrepancies between the implant positions captured by each photogrammetry system and the reference dataset. Secondary outcome measures will include the chairside time required for scan acquisition. Statistical analyses will be performed to compare the accuracy and efficiency of the evaluated systems.

Tanulmány típusa

Megfigyelő

Beiratkozás (Tényleges)

24

Kapcsolatok és helyek

Ez a rész a vizsgálatot végzők elérhetőségeit, valamint a vizsgálat lefolytatásának helyére vonatkozó információkat tartalmazza.

Tanulmányi helyek

    • Menoufia
      • Shibīn al Kawm, Menoufia, Egyiptom, 2266166
        • Mohammed El-Sawy

Részvételi kritériumok

A kutatók olyan embereket keresnek, akik megfelelnek egy bizonyos leírásnak, az úgynevezett jogosultsági kritériumoknak. Néhány példa ezekre a kritériumokra a személy általános egészségi állapota vagy a korábbi kezelések.

Jogosultsági kritériumok

Tanulmányozható életkorok

  • Felnőtt

Egészséges önkénteseket fogad

N/A

Mintavételi módszer

Nem valószínűségi minta

Tanulmányi populáció

The study population will consist of adult completely edentulous patients who have been rehabilitated with implant-supported complete-arch prostheses. Eligible participants will present with a fully edentulous arch restored by at least four osseointegrated dental implants and will be recruited from patients seeking prosthodontic treatment and follow-up care at the study center. All participants will undergo complete-arch implant scanning using both an intraoral photogrammetry system and a mobile-phone-based photogrammetry system for comparative evaluation of scan accuracy and chairside acquisition time. Only patients meeting the predefined inclusion criteria and providing written informed consent will be enrolled.

Leírás

Inclusion Criteria:

  • Adults aged 18 years or older.
  • Completely edentulous patients rehabilitated with implant-supported complete-arch prostheses.
  • Presence of at least four osseointegrated implants in the edentulous arch.
  • Patients able to undergo digital implant scanning procedures.
  • Patients willing to participate and provide written informed consent.

Exclusion Criteria:

  • Patients with unstable or failed implants.
  • Presence of peri-implant disease, active oral infection, or significant soft-tissue inflammation around the implants.
  • Inadequate access for placement of photogrammetry scan bodies or markers.
  • Patients with conditions that prevent proper scanning procedures (e.g., inability to maintain mouth opening or remain still during data acquisition).
  • Patients requiring immediate implant placement or immediate loading protocols.
  • Patients unwilling or unable to provide informed consent.
  • Incomplete clinical records or inability to complete all study procedures.

Tanulási terv

Ez a rész a vizsgálati terv részleteit tartalmazza, beleértve a vizsgálat megtervezését és a vizsgálat mérését.

Hogyan készül a tanulmány?

Tervezési részletek

Kohorszok és beavatkozások

Csoport / Kohorsz
Beavatkozás / kezelés
Intraoral Photogrammetry (IPG)
Participants will undergo complete-arch implant scanning using an intraoral photogrammetry system (IPF Elite, Shining 3D). Implant positions will be digitally recorded according to the manufacturer's instructions. Linear and angular discrepancies relative to the reference dataset, as well as chairside scanning time, will be evaluated.
A photogrammetry-based digital impression system used to capture the three-dimensional positions of implants in complete-arch rehabilitations. The system records implant locations through specialized scan bodies and generates a digital dataset for subsequent accuracy analysis.
Más nevek:
  • IPF Elite; Shining 3D; Intraoral Photogrammetry System
Mobile-Phone-Based Photogrammetry
Participants will undergo complete-arch implant scanning using a mobile-phone-based photogrammetry system (T-Marker). Implant positions will be digitally recorded according to the manufacturer's instructions. Linear and angular discrepancies relative to the reference dataset, as well as chairside scanning time, will be evaluated.
A smartphone-assisted photogrammetry system used to capture the three-dimensional positions of implants in complete-arch rehabilitations. The system acquires photographic data through coded markers and generates a digital dataset for subsequent accuracy analysis.
Más nevek:
  • T-Marker; Extraoral Photogrammetry; Mobile-Phone-Based Photogrammetry System

Mit mér a tanulmány?

Elsődleges eredményintézkedések

Eredménymérő
Intézkedés leírása
Időkeret
Linear Discrepancy of Complete-Arch Implant Scans
Időkeret: Immediately after scan acquisition and digital analysis (same study visit).
Assessment of the linear deviation (μm) between implant positions captured using intraoral photogrammetry and mobile-phone-based photogrammetry systems and those recorded in the reference dataset. Lower values indicate greater accuracy.
Immediately after scan acquisition and digital analysis (same study visit).

Együttműködők és nyomozók

Itt találhatja meg a tanulmányban érintett személyeket és szervezeteket.

Együttműködők

Nyomozók

  • Kutatásvezető: Mohammed A. El-Sawy, PhD, Menoufia University

Tanulmányi rekorddátumok

Ezek a dátumok nyomon követik a ClinicalTrials.gov webhelyre benyújtott vizsgálati rekordok és összefoglaló eredmények benyújtásának folyamatát. A vizsgálati feljegyzéseket és a jelentett eredményeket a Nemzeti Orvostudományi Könyvtár (NLM) felülvizsgálja, hogy megbizonyosodjon arról, hogy megfelelnek-e az adott minőség-ellenőrzési szabványoknak, mielőtt közzéteszik őket a nyilvános weboldalon.

Tanulmány főbb dátumok

Tanulmány kezdete (Tényleges)

2026. január 1.

Elsődleges befejezés (Tényleges)

2026. június 1.

A tanulmány befejezése (Tényleges)

2026. augusztus 1.

Tanulmányi regisztráció dátumai

Először benyújtva

2026. június 7.

Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak

2026. június 7.

Első közzététel (Tényleges)

2026. június 11.

Tanulmányi rekordok frissítései

Utolsó frissítés közzétéve (Tényleges)

2026. szeptember 16.

Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak

2026. szeptember 13.

Utolsó ellenőrzés

2026. szeptember 1.

Több információ

A tanulmányhoz kapcsolódó kifejezések

Egyéb vizsgálati azonosító számok

  • R.26.125

Terv az egyéni résztvevői adatokhoz (IPD)

Tervezi megosztani az egyéni résztvevői adatokat (IPD)?

NEM

IPD terv leírása

Up on resonable request from the corresponding author

Gyógyszer- és eszközinformációk, tanulmányi dokumentumok

Egy amerikai FDA által szabályozott gyógyszerkészítményt tanulmányoz

Nem

Egy amerikai FDA által szabályozott eszközterméket tanulmányoz

Nem

Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .

Iratkozz fel