Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

Accuracy of Complete-Arch Implant Photogrammetry

7 czerwca 2026 zaktualizowane przez: Mohammed El-Sawy, Menoufia University

Accuracy of Complete-arch Implant Scans Obtained Using Intraoral Photogrammetry and a Mobile-phone Based Photogrammetry.

This prospective comparative clinical study evaluated the accuracy and chairside time of complete-arch implant scans obtained using an intraoral photogrammetry system and a mobile-phone-based photogrammetry system in edentulous patients rehabilitated with complete-arch implant-supported prostheses. Implant positions recorded by each system were compared with a reference dataset to assess linear and angular discrepancies. The chairside time required for data acquisition was also measured. The study aimed to determine whether mobile-phone-based photogrammetry can provide clinically acceptable accuracy comparable to that of intraoral photogrammetry while improving clinical efficiency. The findings may help clinicians select appropriate digital impression techniques for complete-arch implant rehabilitation.

Przegląd badań

Szczegółowy opis

Accurate recording of implant positions is essential for the passive fit and long-term success of complete-arch implant-supported prostheses. Photogrammetry-based technologies have emerged as promising alternatives to conventional digital impression techniques for capturing implant positions with high accuracy. While intraoral photogrammetry systems have demonstrated favorable results, the clinical performance of recently introduced mobile-phone-based photogrammetry systems remains insufficiently investigated.

This prospective comparative clinical study aims to evaluate the accuracy and chairside time of complete-arch implant scans obtained using an intraoral photogrammetry system and a mobile-phone-based photogrammetry system in edentulous patients restored with complete-arch implant-supported prostheses. Each participant will undergo implant scanning using both systems according to the manufacturers' recommendations. The resulting digital datasets will be compared with a reference dataset to determine scan accuracy.

The primary outcome measures will be linear and angular discrepancies between the implant positions captured by each photogrammetry system and the reference dataset. Secondary outcome measures will include the chairside time required for scan acquisition. Statistical analyses will be performed to compare the accuracy and efficiency of the evaluated systems.

Typ studiów

Obserwacyjny

Zapisy (Szacowany)

42

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Kontakt w sprawie studiów

Lokalizacje studiów

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

  • Dorosły

Akceptuje zdrowych ochotników

Nie dotyczy

Metoda próbkowania

Próbka bez prawdopodobieństwa

Badana populacja

The study population will consist of adult completely edentulous patients who have been rehabilitated with implant-supported complete-arch prostheses. Eligible participants will present with a fully edentulous arch restored by at least four osseointegrated dental implants and will be recruited from patients seeking prosthodontic treatment and follow-up care at the study center. All participants will undergo complete-arch implant scanning using both an intraoral photogrammetry system and a mobile-phone-based photogrammetry system for comparative evaluation of scan accuracy and chairside acquisition time. Only patients meeting the predefined inclusion criteria and providing written informed consent will be enrolled.

Opis

Inclusion Criteria:

  • Adults aged 18 years or older.
  • Completely edentulous patients rehabilitated with implant-supported complete-arch prostheses.
  • Presence of at least four osseointegrated implants in the edentulous arch.
  • Patients able to undergo digital implant scanning procedures.
  • Patients willing to participate and provide written informed consent.

Exclusion Criteria:

  • Patients with unstable or failed implants.
  • Presence of peri-implant disease, active oral infection, or significant soft-tissue inflammation around the implants.
  • Inadequate access for placement of photogrammetry scan bodies or markers.
  • Patients with conditions that prevent proper scanning procedures (e.g., inability to maintain mouth opening or remain still during data acquisition).
  • Patients requiring immediate implant placement or immediate loading protocols.
  • Patients unwilling or unable to provide informed consent.
  • Incomplete clinical records or inability to complete all study procedures.

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

Kohorty i interwencje

Grupa / Kohorta
Interwencja / Leczenie
Intraoral Photogrammetry (IPG)
Participants will undergo complete-arch implant scanning using an intraoral photogrammetry system (IPF Elite, Shining 3D). Implant positions will be digitally recorded according to the manufacturer's instructions. Linear and angular discrepancies relative to the reference dataset, as well as chairside scanning time, will be evaluated.
A photogrammetry-based digital impression system used to capture the three-dimensional positions of implants in complete-arch rehabilitations. The system records implant locations through specialized scan bodies and generates a digital dataset for subsequent accuracy analysis.
Inne nazwy:
  • IPF Elite; Shining 3D; Intraoral Photogrammetry System
Mobile-Phone-Based Photogrammetry
Participants will undergo complete-arch implant scanning using a mobile-phone-based photogrammetry system (T-Marker). Implant positions will be digitally recorded according to the manufacturer's instructions. Linear and angular discrepancies relative to the reference dataset, as well as chairside scanning time, will be evaluated.
A smartphone-assisted photogrammetry system used to capture the three-dimensional positions of implants in complete-arch rehabilitations. The system acquires photographic data through coded markers and generates a digital dataset for subsequent accuracy analysis.
Inne nazwy:
  • T-Marker; Extraoral Photogrammetry; Mobile-Phone-Based Photogrammetry System

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Linear Discrepancy of Complete-Arch Implant Scans
Ramy czasowe: Immediately after scan acquisition and digital analysis (same study visit).
Assessment of the linear deviation (μm) between implant positions captured using intraoral photogrammetry and mobile-phone-based photogrammetry systems and those recorded in the reference dataset. Lower values indicate greater accuracy.
Immediately after scan acquisition and digital analysis (same study visit).

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Współpracownicy

Śledczy

  • Główny śledczy: Mohammed A. El-Sawy, PhD, Menoufia University

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Rzeczywisty)

1 stycznia 2026

Zakończenie podstawowe (Szacowany)

1 sierpnia 2026

Ukończenie studiów (Szacowany)

1 sierpnia 2026

Daty rejestracji na studia

Pierwszy przesłany

7 czerwca 2026

Pierwszy przesłany, który spełnia kryteria kontroli jakości

7 czerwca 2026

Pierwszy wysłany (Rzeczywisty)

11 czerwca 2026

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

11 czerwca 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

7 czerwca 2026

Ostatnia weryfikacja

1 czerwca 2026

Więcej informacji

Terminy związane z tym badaniem

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

NIE

Opis planu IPD

Up on resonable request from the corresponding author

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Badania kliniczne na Bezzębna szczęka

Badania kliniczne na Intraoral Photogrammetry (IPG)