Failure Rate of Infra-Zygomatic Orthodontic Mini-Screws
Factors Associated With the Failure Rate of Infra-Zygomatic Orthodontic Mini-Screws
연구 개요
상태
정황
상세 설명
Researchers will evaluate the influence of mini-screw length, diameter, oral hygiene status, age, sex, and loading time on the failure rate of infra-zygomatic mini-screws. Mini-screw failure will be assessed clinically by the presence of mobility or loss of stability.
Participants will:
- Receive fixed orthodontic treatment with a pre-adjusted edgewise appliance system.
- Receive infra-zygomatic mini-screws bilaterally for maxillary anchorage reinforcement.
- Receive a 10 mm × 1.8 mm mini-screw on one side with immediate loading.
- Receive a 12 mm × 2.0 mm mini-screw on the contralateral side with delayed loading.
- Receive standardized orthodontic force using elastic power chain.
- Undergo CBCT assessment to evaluate the position of the inserted mini-screws.
- Be evaluated at baseline and at one-month intervals for three consecutive months to assess mini-screw mobility or failure.
연구 유형
등록 (추정된)
단계
- 해당 없음
연락처 및 위치
연구 장소
-
-
-
Dhaka, 방글라데시, 1000
- Bangladesh Medical University (BMU), Dhaka,1000
-
-
참여기준
자격 기준
공부할 수 있는 나이
- 성인
건강한 자원 봉사자를 받아들입니다
설명
Inclusion Criteria:
- Participants aged 19 to 35 years.
- Both male and female participants.
- Patients requiring absolute anchorage for maxillary arch and orthodontic tooth movement.
- Patients undergoing fixed orthodontic treatment.
- Patients in whom infra-zygomatic mini-screws are indicated for anchorage reinforcement.
- Participants whose oral hygiene status can be clinically assessed.
- Participants willing to provide written informed consent.
Exclusion Criteria:
- Patients with incomplete history or records
- Patients with a history of previous orthodontic treatment.
- Patients with a history of maxillofacial surgery.
- Patients with a history of head or facial trauma.
- Patients with temporomandibular joint disorder.
- Medically compromised patients.
- Patients with diagnosed syndromes, congenital defects, or facial deformities.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 치료
- 할당: 무작위
- 중재 모델: 병렬 할당
- 마스킹: 없음(오픈 라벨)
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
활성 비교기: Immediate loading mini-screw group
A 10 mm length and 1.8 mm diameter infra-zygomatic mini-screw will be placed on one side of the maxillary arch and loaded immediately with orthodontic force.
|
A 10 mm length and 1.8 mm diameter infra-zygomatic mini-screw will be placed on one side of the maxillary arch and loaded immediately with orthodontic force.
|
|
활성 비교기: Delayed loading mini-screw group
A 12 mm length and 2.0 mm diameter infra-zygomatic mini-screw will be placed on the contralateral side of the maxillary arch and loaded after a delayed period.
|
A 12 mm length and 2.0 mm diameter infra-zygomatic mini-screw will be placed on the contralateral side of the maxillary arch and loaded after a delayed period
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
To assess the failure rate of infra-zygomatic orthodontic mini-screws over a three-month follow-up period. Failure will be defined as any degree of clinical mobility or loss of stability of the mini-screw.
기간: over a three-month follow-up period
|
This is a split-mouth randomized clinical study in which each participant will receive infra-zygomatic mini-screws bilaterally.
One side will receive a 10 mm × 1.8 mm mini-screw with immediate loading, while the contralateral side will receive a 12 mm × 2.0 mm mini-screw with delayed loading.
The failure rate will be assessed clinically over a three-month follow-up period.Mini-screw failure will be assessed clinically by the presence of mobility or loss of stability.
|
over a three-month follow-up period
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
To assess the failure rate of infra-zygomatic orthodontic mini-screws over a three-month follow-up period. Failure will be defined as any degree of clinical mobility or loss of stability of the mini-screw
기간: Over a three-month follow-up period.
|
|
Over a three-month follow-up period.
|
기타 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Factors Associated with the Failure Rate of Infra-Zygomatic Orthodontic Mini-Screws
기간: From October 25 to September 26
|
This randomized clinical study will assess the factors associated with the failure rate of infra-zygomatic crest orthodontic mini-screws used for anchorage reinforcement during orthodontic treatment. Researchers will evaluate the influence of mini-screw length, diameter, oral hygiene status, age, sex, and loading time on the failure rate of infra-zygomatic mini-screws. Mini-screw failure will be assessed clinically by the presence of mobility or loss of stability. Participants will receive:
|
From October 25 to September 26
|
공동 작업자 및 조사자
스폰서
수사관
- 연구 책임자: Mahmood Sajedeen, BDS,FCPS, Bangladesh Medical University (BMU)
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
키워드
기타 연구 ID 번호
- BMU/2026/1583
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .