Tato stránka byla automaticky přeložena a přesnost překladu není zaručena. Podívejte se prosím na anglická verze pro zdrojový text.

Failure Rate of Infra-Zygomatic Orthodontic Mini-Screws

18. června 2026 aktualizováno: Tanzila Rafique

Factors Associated With the Failure Rate of Infra-Zygomatic Orthodontic Mini-Screws

The goal of this randomized clinical study is to assess the factors associated with the failure rate of infra-zygomatic crest orthodontic mini-screws used for anchorage reinforcement during orthodontic treatment.

Přehled studie

Detailní popis

Researchers will evaluate the influence of mini-screw length, diameter, oral hygiene status, age, sex, and loading time on the failure rate of infra-zygomatic mini-screws. Mini-screw failure will be assessed clinically by the presence of mobility or loss of stability.

Participants will:

  • Receive fixed orthodontic treatment with a pre-adjusted edgewise appliance system.
  • Receive infra-zygomatic mini-screws bilaterally for maxillary anchorage reinforcement.
  • Receive a 10 mm × 1.8 mm mini-screw on one side with immediate loading.
  • Receive a 12 mm × 2.0 mm mini-screw on the contralateral side with delayed loading.
  • Receive standardized orthodontic force using elastic power chain.
  • Undergo CBCT assessment to evaluate the position of the inserted mini-screws.
  • Be evaluated at baseline and at one-month intervals for three consecutive months to assess mini-screw mobility or failure.

Typ studie

Intervenční

Zápis (Odhadovaný)

30

Fáze

  • Nelze použít

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní místa

      • Dhaka, Bangladéš, 1000
        • Bangladesh Medical University (BMU), Dhaka,1000

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

  • Dospělý

Přijímá zdravé dobrovolníky

Ano

Popis

Inclusion Criteria:

  • Participants aged 19 to 35 years.
  • Both male and female participants.
  • Patients requiring absolute anchorage for maxillary arch and orthodontic tooth movement.
  • Patients undergoing fixed orthodontic treatment.
  • Patients in whom infra-zygomatic mini-screws are indicated for anchorage reinforcement.
  • Participants whose oral hygiene status can be clinically assessed.
  • Participants willing to provide written informed consent.

Exclusion Criteria:

  • Patients with incomplete history or records
  • Patients with a history of previous orthodontic treatment.
  • Patients with a history of maxillofacial surgery.
  • Patients with a history of head or facial trauma.
  • Patients with temporomandibular joint disorder.
  • Medically compromised patients.
  • Patients with diagnosed syndromes, congenital defects, or facial deformities.

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

  • Primární účel: Léčba
  • Přidělení: Randomizované
  • Intervenční model: Paralelní přiřazení
  • Maskování: Žádné (otevřený štítek)

Zbraně a zásahy

Skupina účastníků / Arm
Intervence / Léčba
Aktivní komparátor: Immediate loading mini-screw group
A 10 mm length and 1.8 mm diameter infra-zygomatic mini-screw will be placed on one side of the maxillary arch and loaded immediately with orthodontic force.
A 10 mm length and 1.8 mm diameter infra-zygomatic mini-screw will be placed on one side of the maxillary arch and loaded immediately with orthodontic force.
Aktivní komparátor: Delayed loading mini-screw group
A 12 mm length and 2.0 mm diameter infra-zygomatic mini-screw will be placed on the contralateral side of the maxillary arch and loaded after a delayed period.
A 12 mm length and 2.0 mm diameter infra-zygomatic mini-screw will be placed on the contralateral side of the maxillary arch and loaded after a delayed period

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
To assess the failure rate of infra-zygomatic orthodontic mini-screws over a three-month follow-up period. Failure will be defined as any degree of clinical mobility or loss of stability of the mini-screw.
Časové okno: over a three-month follow-up period
This is a split-mouth randomized clinical study in which each participant will receive infra-zygomatic mini-screws bilaterally. One side will receive a 10 mm × 1.8 mm mini-screw with immediate loading, while the contralateral side will receive a 12 mm × 2.0 mm mini-screw with delayed loading. The failure rate will be assessed clinically over a three-month follow-up period.Mini-screw failure will be assessed clinically by the presence of mobility or loss of stability.
over a three-month follow-up period

Sekundární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
To assess the failure rate of infra-zygomatic orthodontic mini-screws over a three-month follow-up period. Failure will be defined as any degree of clinical mobility or loss of stability of the mini-screw
Časové okno: Over a three-month follow-up period.
  • To compare the failure rate of infra-zygomatic mini-screws according to age and sex of the participants.
  • To evaluate the influence of mini-screw length on failure rate.
  • To evaluate the influence of mini-screw diameter on failure rate.
  • To assess the relationship between oral hygiene status and mini-screw failure.
  • To compare the effect of immediate and delayed loading on mini-screw failure.
  • To assess the position of inserted mini-screws using CBCT.
  • To evaluate the clinical usefulness of infra-zygomatic mini-screws as temporary anchorage devices in orthodontic treatment.
Over a three-month follow-up period.

Další výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Factors Associated with the Failure Rate of Infra-Zygomatic Orthodontic Mini-Screws
Časové okno: From October 25 to September 26

This randomized clinical study will assess the factors associated with the failure rate of infra-zygomatic crest orthodontic mini-screws used for anchorage reinforcement during orthodontic treatment. Researchers will evaluate the influence of mini-screw length, diameter, oral hygiene status, age, sex, and loading time on the failure rate of infra-zygomatic mini-screws. Mini-screw failure will be assessed clinically by the presence of mobility or loss of stability.

Participants will receive:

  • fixed orthodontic treatment with a pre-adjusted edgewise appliance system
  • infra-zygomatic mini-screws bilaterally for maxillary anchorage reinforcement
  • 10 mm × 1.8 mm mini-screw on one side with immediate loading
  • a 12 mm × 2.0 mm mini-screw on the contralateral side with delayed loading
  • standardized orthodontic force using elastic power chain CBCT will be carried out at baseline and at one-month intervals for three consecutive months to assess mini-screw mobility or failure.
From October 25 to September 26

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Sponzor

Vyšetřovatelé

  • Ředitel studie: Mahmood Sajedeen, BDS,FCPS, Bangladesh Medical University (BMU)

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Aktuální)

1. září 2025

Primární dokončení (Odhadovaný)

30. prosince 2026

Dokončení studie (Odhadovaný)

8. února 2027

Termíny zápisu do studia

První předloženo

11. června 2026

První předloženo, které splnilo kritéria kontroly kvality

18. června 2026

První zveřejněno (Aktuální)

22. června 2026

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

22. června 2026

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

18. června 2026

Naposledy ověřeno

1. června 2026

Více informací

Termíny související s touto studií

Plán pro data jednotlivých účastníků (IPD)

Plánujete sdílet data jednotlivých účastníků (IPD)?

NE

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .

Klinické studie na Ortodontické kotevní postupy

Předplatit