- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT07767968
LapBox® Manual Containment System
Evaluation of Leak Integrity of the LapBox® Manual Containment System During Laparoscopic Surgery
연구 개요
상세 설명
The goal is to determine the integrity of the LapBox Manual Containment system in order to increase surgical safety of morcellation of uterine fibroids during laparoscopic hysterectomy and myomectomy.
Containment systems are imperative for laparoscopic morcellation due to the potential for tissue dissemination, particularly in cases of undiagnosed malignancy or benign tissue fragments during morcellation of uterine fibroids.
Integrity of the LapBox Manual Containment System will be evaluated by indicating the presence or absence of leakage from testing with methylene blue dye after morcellation. The LapBox and standard of care devices will be moved away from the surgical field prior to methylene blue being added to determine if there is breakage. The methylene blue dye will not come in contact with the participant or spill onto the surgical field.
The hypothesis is that laparoscopic hysterectomies and myomectomies performed using the LapBox Manual Containment System will result in less leakage when compared to the control containment system.
The primary endpoint will be presence or absence of leakage from the LapBox and the control. This will be directly visualized intraoperatively after morcellation takes place.
The secondary endpoint will be the incidence of perforation or rupture incidence in the LapBox or standard of care device and descriptive comments from surgeons for usability feedback.
연구 유형
등록 (추정된)
단계
- 해당 없음
연락처 및 위치
연구 연락처
- 이름: Sharon Blohowiak
- 전화번호: (608) 262-5977
- 이메일: sblohowiak@wisc.edu
연구 장소
-
-
Wisconsin
-
Madison, Wisconsin, 미국, 53715
- Meriter
-
-
참여기준
자격 기준
공부할 수 있는 나이
- 성인
- 고령자
건강한 자원 봉사자를 받아들입니다
설명
Inclusion Criteria:
- Participants who require laparoscopic hysterectomy or myomectomy for management of uterine fibroids
Exclusion Criteria:
-
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 치료
- 할당: 무작위
- 중재 모델: 병렬 할당
- 마스킹: 더블
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
실험적: LapBox Manual Containment System
N=12
|
The LapBox Manual introduces a double wall, pressure resistant system to maintain safe separation between the cutting instrument and chamber wall.
The LapBox Manual is already FDA-approved for use so this will be a post-market analysis.
다른 이름들:
|
|
활성 비교기: Standard Specimen Bag
N=12
|
Meriter has an endoscopic specimen retrieval bag which will be the standard of care specimen bag depending on the size of the uterine fibroids.
The bag can be deployed through a 15 mm port.
The standard bag is selected depending on the size of the uterine fibroids.
다른 이름들:
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Presence or Absence of Leakage
기간: data collected intraoperatively (on day of surgery, only study visit)
|
Integrity will be evaluated by indicating the presence or absence of leakage after morcellation and subsequent testing with methylene blue dye during laparoscopic hysterectomy or myomectomy.
|
data collected intraoperatively (on day of surgery, only study visit)
|
2차 결과 측정
결과 측정 |
기간 |
|---|---|
|
Incidence of Perforation or Rupture
기간: data collected intraoperatively (on day of surgery, only study visit)
|
data collected intraoperatively (on day of surgery, only study visit)
|
공동 작업자 및 조사자
수사관
- 수석 연구원: Bala Bhagavath, MD, UW School of Medicine and Public Health
연구 기록 날짜
연구 주요 날짜
연구 시작 (추정된)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
키워드
추가 관련 MeSH 약관
기타 연구 ID 번호
- 2026-0071
- Protocol Version 6/22/26 (기타 식별자: UW Madison)
- SMPH | OBGYN Administration (기타 식별자: UW Madison)
- 238739 (기타 식별자: OnCore ID)
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
미국에서 제조되어 미국에서 수출되는 제품
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .