A comparison of continuous infusion and intermittent bolus administration of 0.1% ropivacaine with 0.0002% fentanyl for epidural labor analgesia

Chinmayi Surendra Patkar, Kalpana Vora, Harshal Patel, Veena Shah, Manisha Pranjal Modi, Geeta Parikh, Chinmayi Surendra Patkar, Kalpana Vora, Harshal Patel, Veena Shah, Manisha Pranjal Modi, Geeta Parikh

Abstract

Background and aims: Minimal consumption of local anesthetic and opioid for epidural labor analgesia has been advocated for safe obstetric outcome and superior maternal satisfaction. The primary objective of this study was to evaluate and compare the analgesic efficacy of mode of administration of epidural 0.1% ropivacaine with 0.0002% fentanyl via continuous infusion or intermittent boluses during labor.

Material and methods: Sixty term primi or second gravida healthy parturients in labor requesting epidural analgesia were recruited in this study. Lumbar epidural catheter was inserted, and analgesia initiated with 0.2% ropivacaine. Patients were randomized to receive ropivacaine 0.1% with fentanyl 0.0002% via either continuous infusion (Group A) or intermittent boluses (Group B) on an hourly basis. If the parturient complained of pain and visual analog scale (VAS) score was >3, an additional bolus of the study drug was given. VAS score, motor blockade, maternal hemodynamics and fetal heart sounds were frequently monitored. Side effects, mode of delivery and neonatal outcome were noted.

Results: To achieve similar VAS, the mean total dose of ropivacaine was 18.78 ± 3.88 mg in Group A and 16.86 ± 4.3 mg in Group B, the difference being statistically significant (P = 0.04). Seventeen out of 30 patients in Group A that is, 56.6% and nine patients in Group B that is, 30% required additional top-ups, and this was significantly higher (P = 0.037). Side effects, mode of delivery and neonatal outcome were comparable in both groups.

Conclusion: Intermittent bolus administration provides a more efficacious route of drug delivery when compared to continuous infusion by significantly decreasing the total amount of local anesthetic plus opioid without adversely affecting patient safety or maternal satisfaction.

Keywords: Analgesia; epidural; local anesthetics; ropivacaine.

Conflict of interest statement

Conflict of Interest: None declared.

Figures

Figure 1
Figure 1
Median visual analog scale score. The figure shows median visual analog scale (VAS) scores against time for the two groups. No significant difference in VAS scores between the two groups at any time during labor (P > 0.05)
Figure 2
Figure 2
Distribution of mode of delivery. The pie chart illustrates the distribution of mode of delivery in both groups. No significant difference exists between the two groups (P > 0.05)
Figure 3
Figure 3
Intrapartum hemodynamics. Heart rate and mean arterial pressure plotted against time during labor. There is no significant difference between the two groups (P > 0.05)

References

    1. Shidhaye RV, Galande MV, Bangal VB, Joshi SS, Shidhaye UR. Awareness and attitude towards labour analgesia of Indian pregnant women. Anaesth Pain Intensive Care. 2012;16:131–6.
    1. Salim R, Nachum Z, Moscovici R, Lavee M, Shalev E. Continuous compared with intermittent epidural infusion on progress of labor and patient satisfaction. Obstet Gynecol. 2005;106:301–6.
    1. Usha Kiran TS, Thakur MB, Bethel JA, Bhal PS, Collis RE. Comparison of continuous infusion versus midwife administered top-ups of epidural bupivacaine for labour analgesia: Effect on second stage of labour and mode of delivery. Int J Obstet Anesth. 2003;12:9–11.
    1. Syal K, Dogra R, Ohri A, Chauhan G, Goel A. Epidural labour analgesia using Bupivacaine and Clonidine. J Anaesthesiol Clin Pharmacol. 2011;27:87–90.
    1. Sultan P, Murphy C, Halpern S, Carvalho B. The effect of low concentrations versus high concentrations of local anesthetics for labour analgesia on obstetric and anesthetic outcomes: A meta-analysis. Can J Anaesth. 2013;60:840–54.
    1. Chua SM, Sia AT. Automated intermittent epidural boluses improve analgesia induced by intrathecal fentanyl during labour. Can J Anaesth. 2004;51:581–5.
    1. Fettes PD, Moore CS, Whiteside JB, McLeod GA, Wildsmith JA. Intermittent vs continuous administration of epidural ropivacaine with fentanyl for analgesia during labour. Br J Anaesth. 2006;97:359–64.
    1. Sharma S, Menia V, Bedi J, Dogra S. Labor analgesia: An unmet right of laboring women in India. J South Asian Fed Obstet Gynaecol. 2013;5:26–32.
    1. Lee BB, Ngan Kee WD, Lau WM, Wong AS. Epidural infusions for labor analgesia: A comparison of 0.2% ropivacaine, 0.1% ropivacaine, and 0.1% ropivacaine with fentanyl. Reg Anesth Pain Med. 2002;27:31–6.
    1. Fernández-Guisasola J, Serrano ML, Cobo B, Muñoz L, Plaza A, Trigo C, et al. A comparison of 0.0625% bupivacaine with fentanyl and 0.1% ropivacaine with fentanyl for continuous epidural labor analgesia. Anesth Analg. 2001;92:1261–5.
    1. Paddalwar S, Nagrale M, Chandak A, Shrivastava D, Papalkar J. A randomized, double-blind, controlled study comparing bupivacaine 0.125% and ropivacaine 0.125%, both with fentanyl 2 μg/ml, for labor epidural analgesia. Indian J Pain. 2013;27:147–53.
    1. Chhetty YK, Naithani U, Gupta S, Bedi V, Agrawal I, Swain L. Epidural labor analgesia: A comparison of ropivacaine 0.125% versus 0.2% with fentanyl. J Obstet Anaesth Crit Care. 2013;3:16–22.
    1. Pandya ST. Labour analgesia: Recent advances. Indian J Anaesth. 2010;54:400–8.
    1. Lim Y, Sia AT, Ocampo C. Automated regular boluses for epidural analgesia: A comparison with continuous infusion. Int J Obstet Anesth. 2005;14:305–9.
    1. Capogna G, Camorcia M, Stirparo S, Farcomeni A. Programmed intermittent epidural bolus versus continuous epidural infusion for labor analgesia: The effects on maternal motor function and labor outcome. A randomized double-blind study in nulliparous women. Anesth Analg. 2011;113:826–31.
    1. Lim Y, Chakravarty S, Ocampo CE, Sia AT. Comparison of automated intermittent low volume bolus with continuous infusion for labour epidural analgesia. Anaesth Intensive Care. 2010;38:894–9.
    1. Wong CA, Ratliff JT, Sullivan JT, Scavone BM, Toledo P, McCarthy RJ. A randomized comparison of programmed intermittent epidural bolus with continuous epidural infusion for labor analgesia. Anesth Analg. 2006;102:904–9.
    1. Reynolds F. The effects of maternal labour analgesia on the fetus. Best Pract Res Clin Obstet Gynaecol. 2010;24:289–302.
    1. Kumar K, Singh SI. Neuraxial opioid-induced pruritus: An update. J Anaesthesiol Clin Pharmacol. 2013;29:303–7.
    1. Alehagen S, Wijma K, Wijma B. Fear during labor. Acta Obstet Gynecol Scand. 2001;80:315–20.

Source: PubMed

3
구독하다