Immediate Postoperative Portable Radiograph After Total Knee Replacements: A Necessity or a Burden?

Abdulla Aljawder, Dana Alomran, Mohammed Alayyoub, Fahad Alkhalifa, Abdulla Aljawder, Dana Alomran, Mohammed Alayyoub, Fahad Alkhalifa

Abstract

Background: Total Knee Replacement (TKR) is one of the most commonly performed orthopaedic surgery(1). Immediate postoperative portable radiographs are performed after primary TKR in order to identify any potential complications and technical flaws. It also serves as a reference for comparison with subsequent radiographs. The aim of this study was to evaluate the clinical and economical value of these radiographs in TKR. It compares the quality of the portable radiograph, taken immediately post-operation, with in-suite radiographs taken 5-7 weeks post-operation.

Methods: In this retrospective study, a consecutive series of 389 TKR patients from January-2011 to March-2015 were reviewed. Radiological evaluation consisted of assessing the beam angle and the exposure on the images. Implant positioning was also compared by measuring the anatomical axis to look for component alignment discrepancies.

Results: The quality of the portable recovery room radiograph was overall inferior to the radiology suite radiograph regarding both beam angle and exposure. Component alignment discrepancies were also identified in the angle measurements between both types of radiographs.

Conclusion: Therefore, our study demonstrated that there is no clinical or financial value obtained from postoperative portable radiograph. Furthermore, Immediate recovery room radiographs should be avoided from being performed routinely and may only be used in cases where the surgeon is utilizing a new implant or technique. No external funding was provided for this study from any source.

Keywords: Arthroplasty; Portable; Postoperative; Radiograph; Recovery room; Total knee replacement.

Figures

Fig. (1)
Fig. (1)
Fig. (2)
Fig. (2)

References

    1. Bhandari Mohit, Smith Jon, Miller Larry E., Block Jon E. Clinical and economic burden of revision knee arthroplasty. Libertas Academica. 2012. pp. 89–94.
    1. Cram P., Lu X., Kates S.L., Singh J.A., Li Y., Wolf B.R. Total knee arthroplasty volume, utilization, and outcomes among Medicare beneficiaries, 1991-2010. JAMA. 2012;308(12):1227–1236. doi: 10.1001/2012.jama.11153.
    1. Elizabeth M. Standard of care: Total knee arthroplasty, physical therapy management of the patient following total knee arthroplasty. BRIGHAM AND WOMEN’S HOSPITAL,Department of Rehabilitation Services. 2008. e.g. 3:1-17.
    1. Plante-Bordeneuve P., Freeman M.A. Tibial high-density polyethylene wear in conforming tibiofemoral prostheses. J. Bone Joint Surg. Br. 1993;75(4):630–636. doi: 10.1302/0301-620X.75B4.8331121.
    1. Kosashvili Y., Alvi M., Mayne I.P., Safir O., Gross A., Backstein D. Immediate recovery room radiographs after primary total knee arthroplasty-why do we keep doing them? Int. Orthop. 2010;34(8):1167–1173. doi: 10.1007/s00264-009-0888-9. [SICOT].
    1. Mohamed E. Moussa, MD; Henrik Malchau, MD, PhD; Andrew A. Freiberg, MD;Young-Min Kwon, MD, PhD. Effect of immediate postoperative portable radiographs on reoperation in primary total knee arthroplasty. Orthopedics. 2014;37(9):817–821. doi: 10.3928/01477447-20140825-59.
    1. Hassan S., Wall A., Ayyaswamy B., Rogers S., Mills S.P., Charalambous C.P. Is there a need for early post-operative x-rays in primary total knee replacements? Experience of a centre in the UK. Ann. R. Coll. Surg. Engl. 2012;94(3):199–200. doi: 10.1308/003588412X13171221501780.
    1. Glaser D., Lotke P. Cost-effectiveness of immediate postoperative radiographs after uncomplicated total knee arthroplasty: A retrospective and prospective study of 750 patients. J. Arthroplasty. 2000;15(4):475–478. doi: 10.1054/arth.2000.4338.
    1. Ververeli P.A., Masonis J.L., Booth R.E., Hozack W.J., Rothman R.H. Radiographic cost reduction strategy in total joint arthroplasty. A prospective analysis. J. Arthroplasty. 1996;11(3):277–280. doi: 10.1016/S0883-5403(96)80078-7.
    1. Kumar N., Yadav C., Raj R., Anand S. How to interpret postoperative X-rays after total knee arthroplasty. Orthop. Surg. 2014;6(3):179–186. doi: 10.1111/os.12123.
    1. Gujarathi N., Putti A.B., Abboud R.J., MacLean J.G., Espley A.J., Kellett C.F. Risk of periprosthetic fracture after anterior femoral notching. Acta Orthop. 2009;80(5):553–556. doi: 10.3109/17453670903350099.
    1. Lavernia C.J. MD, R. A. Hernandez, MD, and J. A. Rodriguez, MSME. The Journal of Arthroplasty. Perioperative X Rays in Arthroplasty Surgery. Outcome and Cost. 1999;14(6):669–671.
    1. Niskanen R.O. Early repetitive radiography is unnecessary after an uncomplicated cemented hip or knee arthroplasty for osteoarthritis. Acta Orthop. Belg. 2005;71(6):692–695.
    1. Moskal J.T., Diduch D.R. Postoperative radiographs after total knee arthroplasty: A cost-containment strategy. Am. J. Knee Surg. 1998;11(2):89–93.
    1. Math K.R., Zaidi S.F., Petchprapa C., Harwin S.F. Imaging of total knee arthroplasty. Semin. Musculoskelet. Radiol. 2006;10(1):47–63. doi: 10.1055/s-2006-934216.
    1. Mihra S. Taljanovic, MD, Marci D. Jones, MD, Tim B. Hunter, MD,James B. Benjamin, MD, John T. Ruth, MD, Andrew,W. Brown, MD,Joseph E. Sheppard, MD. Joint Arthroplasties and Prostheses. Radiographics. 2003;23(5):1294–1314.
    1. Koshino T., Takeyama M., Jiang L.S., Yoshida T., Saito T. Underestimation of varus angulation in knees with flexion deformity. Knee. 2002;9(4):275–279. doi: 10.1016/S0968-0160(02)00049-2.
    1. Beckman A. Design and manufacturing solutions to UHMWPE wear in TKA. Zimmer technical paper, 1997.

Source: PubMed

3
구독하다