Introduction to contrast-enhanced ultrasound of the brain in neonates and infants: current understanding and future potential

Misun Hwang, Misun Hwang

Abstract

Contrast-enhanced ultrasound (CEUS) is a valuable bedside imaging technique that enables both qualitative and quantitative assessment of cerebral perfusion. In neonates and infants whose fontanelles remain open, the technique is particularly useful as it delineates cerebral pathology with high soft-tissue contrast. The technique has the potential to be a valuable alternative to computed tomography (CT) or magnetic resonance imaging (MRI) in critically ill neonates and infants in need of bedside imaging. While further studies are needed to validate the technique, preliminary data in this regard appear promising. This review introduces the current understanding and future potential of brain CEUS.

Keywords: Brain; Clinical protocol; Contrast-enhanced ultrasound; Neonate; Perfusion; Ultrasound.

Figures

Figure 1.. Microbubble Wash-In Time Intensity Curve…
Figure 1.. Microbubble Wash-In Time Intensity Curve (TIC)
The graph represents a time intensity curve generated based on the dynamic microbubble wash-in data. Time 0 represents the time of microbubble injection. Peak enhancement (PE) refers to maximum microbubble intensity (in decibels or dB) during the wash-in phase. The time (sec) it takes from injection to reach PE is called time to peak (TTP). The time from the start of curve rise to peak enhancement is called rise time (RT). The area under the TIC is called wash-in area under the curve (WiAUC) and represents microbubble volume. The slope of the wash-in curve is called wash-in slope or perfusion.
Figure 2.. Dynamic Microbubble Wash-In on Mid-Coronal…
Figure 2.. Dynamic Microbubble Wash-In on Mid-Coronal Brain Scan in a Normal Subject
Figure 2A denotes a mid-coronal grayscale ultrasound scan through the brain of a normal subject showing bilateral frontal lobes (orange arrows), frontal horns (yellow arrowheads), basal ganglia (red arrows), and temporal lobes (white arrows). Figure 2B-G demonstrates dynamic microbubble wash-in through the mid-coronal slice through the brain on a contrast specific mode from the time of injection (time 0) to 1 min. Note that the microbubbles flow into the partially visualized Circle of Willis by 13 seconds. By 15 seconds, relatively more avid enhancement to the basal ganglia with respect to the remainder of the brain is seen. Further enhancement of the cortex but with relative hyperenhancement of the basal ganglia is noted at 20 seconds. Wash-out of contrast from both the basal ganglia and cortex begins at 25 seconds and further wash-out noted at 60 seconds. Note that Figure 2 images were obtained with EPIQ scanner (Phillips Healthcare, Bothell, WA) and C5–1 transducer with settings of 12 Hz and MI of 0.06.
Figure 3.. Multifocal and Symmetric, Diffuse Perfusion…
Figure 3.. Multifocal and Symmetric, Diffuse Perfusion Abnormalities on CEUS-B
Figure 3A depicts a coronal scan through the posterior parietooccipital lobes in a neonate with hypoxic ischemic injury. The image was obtained at 27 seconds after microbubble injection at peak intensity. Generalized hypoperfusion with multifocal perfusion abnormalities noted as evidenced by paucity of microbubbles in scattered areas (white arrows). Figure 3B and 3C, both obtained at 18 seconds after microbubble injection, are neonatal cases of symmetric, diffuse hypoxic ischemic injury resulting in generalized hyperperfusion to the brain in the immediate post-injury period. Figure 3D is an infant post prolonged cardiac arrest demonstrating diffuse hypoperfusion to the brain. Note that Figure 3 images were obtained with EPIQ scanner (Phillips Healthcare, Bothell, WA). Figure 3A was obtained with C5–1 transducer and settings of 12 Hz, MI 0.06, Figure 3B with C9–2 transducer and settings of 13 Hz, MI 0.06, Figure 3C with C9–2 transducer and settings of 7 Hz, MI 0.06, and Figure 3D with C9–2 transducer and settings of 12 Hz, MI 0.06. This figure is adapted from Hwang et al.[2] and Shin et al.[27] with permission.
Figure 4.. Central Gray Nuclei to Cortex…
Figure 4.. Central Gray Nuclei to Cortex Ratio (GNC)
Central gray nuclei to cortex ratio in a 1-month-old male (a, b) and a 14-day-old male (c). The central gray nuclei (basal ganglia and thalami) (red) and cortex (areas excluding central gray nuclei) (yellow) are outlined on a mid-coronal CEUS. The central gray nuclei to cortex (GNC) ratio equals perfusion in central gray nuclei (red) over perfusion in cortex (yellow). Figure (a) and(b) demonstrates a representative case with the normally seen hyperperfusion to the central gray nuclei, with (a) obtained at 10 seconds after microbubble administration and (b) obtained at 15 seconds after administration at peak enhancement. (c) demonstrates a hypoxic ischemic injury case in which the normally seen GNC ratio greater than 1 is absent due to diffuse hyperperfusion to the brain in the immediate post injury setting. In this case, the GNC ratio is noted to be approximately equal to 1. The image was obtained at 18 seconds after microbubble administration at peak enhancement. Note that all the images were obtained with EPIQ scanner (Philips Healthcare, Bothell, WA) and C5–1 transducer with settings of 12 Hz and mechanical index of 0.06.
Figure 5.. Intracranial Hemorrhage on CEUS-B
Figure 5.. Intracranial Hemorrhage on CEUS-B
Figure 5 is a CEUS-B of a neonate with heterogeneous right germinal matrix hemorrhage with associated periventricular edema/infarct (arrowheads) on grayscale ultrasound (A), CEUS-B (B), T2-weighted MR imaging (C). Heterogeneous hypoperfusion is noted in the right periventricular region in the area of known hemorrhage (B). There is mild leftward midline shift and ventricular dilatation with asymmetric effacement of the right frontal horn due to the hemorrhage. Note that the cerebral perfusion in the remainder of the right hemisphere as well as the left hemisphere is preserved (arrows). Note that Figure 5(B) was obtained with EPIQ scanner (Phillips Healthcare, Bothell, WA) and C5–1 transducer with settings of 12 Hz and MI of 0.06.
Figure 6.. Generation of Ultrasound Perfusion Maps…
Figure 6.. Generation of Ultrasound Perfusion Maps from CEUS-B
Figure 6a (A-E) depicts CEUS-B of an infant status post multiple cardiac arrests and extracorporeal membrane oxygenation. Dynamic CEUS-B images from time 0 to 44 seconds demonstrate abnormally avid perfusion to the cortical and subcortical regions of the cerebral cortex as well as the central gray nuclei, resulting in abnormal GNC ratio Higher peak intensity and area under the curve, as well as delayed washout was seen in both regions as compared to normal subjects. Figure 6a (F-H) represents ultrasound perfusion maps reconstructed from the original CEUS-B. Black denotes no perfusion, blue low perfusion, yellow/green moderate perfusion, and red high perfusion relative to the remainder of the brain. Figure 6a-F is a map of wash-in or perfusion and shows fast rate of wash-in (red) in the cortical/subcortical regions as well as the central gray nuclei. Figure 6a-G is a map of peak enhancement and shows accentuation of increased flow in the cortical/subcortical regions greater than the central gray nuclei. Figure 6a-H is a map of wash-in area under the curve or WiAUC which similarly demonstrates increased flow in the cortical/subcortical regions and central gray nuclei. Figure 6I is a coronal T2-weighted MR sequence of the same patient 4 months following the shown CEUS-B scan and demonstrates interval development of marked encephalomalacia and ventriculomegaly due to the severe hypoxic ischemic injury. This figure is adapted from Shin et al.[27] with permission. Note that Figure 6(A-E) was obtained with EPIQ scanner (Phillips Healthcare, Bothell, WA) and C9–2 transducer with settings of 7 Hz and MI of 0.06.

References

    1. Hwang M, de Jong RM, Herman S et al. (2016) Novel Contrast Ultrasound Evaluation in Neonatal Hypoxic Ischemic Injury: Case Series and Future Directions. J Ultrasound Med 36:2379–2386
    1. Hwang M, Riggs BJ, Katz J et al. (2018) Advanced Pediatric Neurosonography Techniques: Contrast-Enhanced Ultrasonography, Elastography, and Beyond. J Neuroimaging 28:150–157.
    1. Hwang M, Sridharan A, Darge K et al. (2018) Novel Quantitative Contrast-Enhanced Ultrasound Detection of Hypoxic Ischemic Injury in Neonates and Infants: Pilot Study I.
    1. Ilves P, Lintrop M, Talvik I et al. (2009) Low cerebral blood flow velocity and head circumference in infants with severe hypoxic ischemic encephalopathy and poor outcome. Acta Paediatr 98:459–465
    1. Okereafor A, Allsop J, Counsell SJ et al. (2008) Patterns of brain injury in neonates exposed to perinatal sentinel events. Pediatrics 121:906–914
    1. Chugani HT, Phelps ME (1986) Maturational changes in cerebral function in infants determined by 18FDG positron emission tomography. Science 231:840–843
    1. Thorngren-Jerneck K, Ohlsson T, Sandell A et al. (2001) Cerebral glucose metabolism measured by positron emission tomography in term newborn infants with hypoxic ischemic encephalopathy. Pediatr Res 49:495–501
    1. Kastler A, Manzoni P, Chapuy S et al. (2014) Transfontanellar contrast enhanced ultrasound in infants: initial experience. J Neuroradiol 41:251–258
    1. Apfel RE, Holland CK (1991) Gauging the likelihood of cavitation from short-pulse, low-duty cycle diagnostic ultrasound. Ultrasound Med Biol 17:179–185
    1. Talu E, Powell RL, Longo ML et al. (2008) Needle size and injection rate impact microbubble contrast agent population. Ultrasound Med Biol 34:1182–1185
    1. Eisenbrey JR, Daecher A, Kramer MR, et al. (2015) Effects of needle and catheter size on commercially available ultrasound contrast agents. J Ultrasound Med 34:1961–1968
    1. Koga M, Reutens DC, Wright P et al. (2005) The existence and evolution of diffusion-perfusion mismatched tissue in white and gray matter after acute stroke. Stroke 36:2132–2137
    1. Berner LP, Cho TH, Haesebaert J et al. (2016) MRI Assessment of ischemic lesion evolution within white and gray matter. Cerebrovasc Dis 41:291–297
    1. de Vries LS, Groenendaal F (2010) Patterns of neonatal hypoxic-ischaemic brain injury. Neuroradiology 52:555–566
    1. Miranda MJ, Olofsson K, Sidaros K (2006) Noninvasive measurements of regional cerebral perfusion in preterm and term neonates by magnetic resonance arterial spin labeling. Pediatr Res 60:359–363
    1. Prada F, Perin A, Martegani A, et al. (2014) Intraoperative contrast-enhanced ultrasound for brain tumor surgery. Neurosurgery 74:542–552
    1. Prada F, Mattei L, Del Bene M et al. (2014) Intraoperative cerebral glioma characterization with contrast enhanced ultrasound. Biomed Res Int
    1. Volpe JJ (2001) Neurology of the Newborn, Philadelphia,
    1. Dykes FD, Dunbar B, Lazarra A et al. (1989) Posthemorrhagic hydrocephalus in high-risk preterm infants: natural history, management, and long-term outcome. J Pediatr 114:611–618
    1. Msall ME, Buck GM, Rogers BT et al. (1991) Risk factors for major neurodevelopmental impairments and need for special education resources in extremely premature infants. J Pediatr 119:606–614
    1. Resch B, Gedermann A, Maurer U, et al. (1996) Neurodevelopmental outcome of hydrocephalus following intra-/periventricular hemorrhage in preterm infants: short- and long-term results. Childs Nerv Syst 12:27–33
    1. International randomised controlled trial of acetazolamide and furosemide in posthaemorrhagic ventricular dilatation in infancy. International PHVD Drug Trial Group (1998) Lancet 352:433–440
    1. Borgesen SE, Gjerris F (1987) Relationships between intracranial pressure, ventricular size, and resistance to CSF outflow. J Neurosurg 67:535–539
    1. Dahlerup B, Gjerris F, Harmsen A et al. (1985) Severe headache as the only symptom of long-standing shunt dysfunction in hydrocephalic children with normal or slit ventricles revealed by computed tomography. Childs Nerv Syst 1:49–52
    1. Ashley WW, McKinstry RC Jr, Leonard JR et al. (2005) Use of rapid-sequence magnetic resonance imaging for evaluation of hydrocephalus in children. J Neurosurg 103:124–130
    1. Brawanski A, Soerensen N (1985) Increased ICP without ventriculomegaly. Diagnostic and therapeutic problems in a 1-year-old boy. Childs Nerv Syst 1:66–68
    1. Shin SS, Bales JW, Edward Dixon C et al. (2017) Structural imaging of mild traumatic brain injury may not be enough: overview of functional and metabolic imaging of mild traumatic brain injury. Brain Imaging Behav 11:591–610

Source: PubMed

3
구독하다