A New Management Technique for Symptomatic Haematomas Following Therapeutic Vacuum-Assisted Biopsy

Florentina Guzmán-Aroca, Juan de Dios Berná-Serna, Ana Azahara García-Ortega, Dolores Hernández-Gómez, Juan de Dios Berná-Mestre, Florentina Guzmán-Aroca, Juan de Dios Berná-Serna, Ana Azahara García-Ortega, Dolores Hernández-Gómez, Juan de Dios Berná-Mestre

Abstract

The aim of this study was to investigate the efficacy of the vacuum-assisted biopsy (VAB) system in evacuating symptomatic haematomas after VAB excision of benign breast lesions. We retrospectively analysed the data of eight patients with symptomatic and large haematomas who were treated with VAB evacuation between 10 and 14 days after VAB excision. Only one case underwent the procedure 24 h after VAB excision, due to the patient reporting intense pain, which was relieved after application of the technique, even though it had to be done twice. This new clinical application of the VAB system for evacuating symptomatic breast haematomas was successful in all the cases in the present study. No technique-related complications were observed. Conclusions: To the best of our knowledge, this is the first study to reveal that VAB evacuation of symptomatic haematomas is safe, effective, quick and well-tolerated by patients.

Keywords: benign lesions; breast; haematoma; ultrasound; vacuum-assisted biopsy.

Conflict of interest statement

The authors declare no conflict of interest.

Figures

Figure 1
Figure 1
Example of a 10G needle with 20 mm aperture (a) and a pedal that includes vacuum (black) and cut (sample) buttons (b). The cutting needle opened at the point labeled 12 (c) and the direction for aspiration was clockwise (d).
Figure 1
Figure 1
Example of a 10G needle with 20 mm aperture (a) and a pedal that includes vacuum (black) and cut (sample) buttons (b). The cutting needle opened at the point labeled 12 (c) and the direction for aspiration was clockwise (d).
Figure 2
Figure 2
Flow diagram of patient inclusion in this study. VAB: vacuum-assisted biopsy; VAS: visual analogue scale; US: ultrasound.
Figure 3
Figure 3
Example of VAB evacuation of a haematoma after VAB excision of a fibroadenoma: (a) the ultrasound image shows a hypoechoic-heterogeneous haematoma; (b) a vacuum-assisted biopsy needle was inserted into the haematoma cavity and we evacuated fluid until the collection disappeared; (c) residual fluid.

References

    1. Lui C.Y., Lam H.S. Review of ultrasound guided vacuum-assisted breast biopsy: Techniques and applications. J. Med. Ultrasound. 2010;18:1–10. doi: 10.1016/S0929-6441(10)60001-X.
    1. Grady I., Gorsuch H., Wilburn-Bailey S. Long-term outcome of benign fibroadenomas treated by ultrasound-guided percutaneous excision. Breast J. 2008;14:275–278. doi: 10.1111/j.1524-4741.2008.00574.x.
    1. Alonso-Bartolomé P., Vega-Bolívar A., Torres-Tabanera M., Ortega E., Acebal-Blanco M., Garijo-Ayensa F., Rodrigo I., Muñoz-Cacho P. Sonographically guided 11-G directional vacuum-assisted breast biopsy as an alternative to surgical excision: Utility and cost study in probably benign lesions. Acta Radiol. 2004;45:390–396. doi: 10.1080/02841850410005633.
    1. Kim M.J., Park B.W., Kim S.I., Youk J.H., Kwak J.Y., Moon H.J., Kim E.K. Long-term follow-up results for ultrasound-guided vacuum-assisted removal of benign palpable breast mass. Am. J. Surg. 2010;199:1–7. doi: 10.1016/j.amjsurg.2008.11.037.
    1. Wang Z.L., Liu G., Li J.L., Ding Q., Su L., Tang J., Ma L. Sonographically guided percutaneous excision of clinically benign breast masses. J. Clin. Ultrasound. 2011;39:1–5. doi: 10.1002/jcu.20752.
    1. Slanetz P.J., Wu S.P., Mendel J.B. Percutaneous excision: A viable alternative to manage benign breast lesions. Can. Assoc. Radiol. J. 2011;62:265–271. doi: 10.1016/j.carj.2010.05.002.
    1. Park H.L., Kim L.S. The current role of vacuum assisted breast biopsy system in breast disease. J. Breast Cancer. 2011;14:1–7. doi: 10.4048/jbc.2011.14.1.1.
    1. Berná-Serna J.D., Guzmán-Aroca F., Berná-Mestre J.D., Hernández-Gómez D. A new method for the prevention of skin laceration during vacuum-assisted breast biopsy. Br. J. Radiol. 2017;90:20160866. doi: 10.1259/bjr.20160866.
    1. American College of Radiology . Breast Imaging Reporting and Data System (BI-RADS) 5th ed. American College of Radiology; Reston, VA, USA: 2013.
    1. Ding B., Chen D., Li X., Zhang H., Zhao Y. Meta analysis of efficacy and safety between Mammotome vacuum-assisted breast biopsy and open excision for benign breast tumor. Gland Surg. 2013;2:69–79.
    1. Ko E.Y., Bae Y.A., Kim M.J., Lee K.S., Lee Y., Kim L.S. Factors affecting the efficacy of ultrasound-guided vacuum-assisted percutaneous excision for removal of benign breast lesions. J. Ultrasound Med. 2008;27:65–73. doi: 10.7863/jum.2008.27.1.65.
    1. Salazar J.P., Miranda I., de Torres J., Rus M.N., Espinosa-Bravo M., Esgueva A., Salvador R., Rubio I.T. Percutaneous ultrasound-guided vacuum-assisted excision of benign breast lesions: A learning curve to assess outcomes. Br. J. Radiol. 2019;92:20180626. doi: 10.1259/bjr.20180626.

Source: PubMed