Clinical Evaluation of Cardiac Resynchronization Therapy (CRT) Using the Ovatio CRT Implantable Cardioverter-defibrillator (ICD) System
Clinical Evaluation of Cardiac Resynchronization Therapy With Implantable Cardioverter-defibrillator Therapy
This study provides a continued access registry for cardiac resynchronization therapy with defibrillation (CRT-D), which helps to resynchronize (coordinate) the rhythm of the heart by helping the left ventricle contract (pump blood) more uniformly, in patients with severe heart failure (New York Heart Association [NYHA] Class III or IV).
Quality of life, adverse events and device success will be analyzed and reported.
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Gedetailleerde beschrijving
ICDs have been shown to increase life expectancy substantially over various drug regimens in patients with life threatening ventricular arrhythmias. Furthermore, large scale studies of cardiac resynchronization therapy in ICD-indicated heart failure patients have demonstrated improvements in functional capacity and quality of life, without unacceptable increases in morbidity or mortality.
This study provides a continued access registry for cardiac resynchronization therapy with defibrillation (CRT-D), which helps to resynchronize (coordinate) the rhythm of the heart by helping the left ventricle contract (pump blood) more uniformly, in patients with severe heart failure (NYHA Class III or IV).
Quality of life, adverse events and device success will be analyzed and reported.
Studietype
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Accepted indication for ICD implant
- Severe heart failure (NYHA Class III or IV) at the time of enrollment
- May have pre-existing ICD, provided subject is on stable, optimal medical regime
- Sinus rhythm with spontaneous QRS duration greater than or equal to 150 ms, or a QRS duration greater than or equal to 130 ms with an inter-ventricular mechanical delay (IVMD) greater than or equal to 40 ms
- Left-ventricular ejection fraction (LVEF) of 35% or less
Exclusion Criteria:
- Any generally accepted indication for standard cardiac pacing, or any contraindication for standard cardiac pacing
- Any contraindication for ICD therapy
- Currently implanted with a lead positioned in or through the coronary sinus
- Hypertrophic or obstructive cardiomyopathy
- Acute myocarditis
- Unstable coronary symptoms (unstable angina or myocardial infarction) within the last month
- Recent or planned cardiac revascularization or coronary angioplasty
- Correctable valvular disease that is the primary cause of heart failure
- Mechanical tricuspid valve
- Chronic atrial arrhythmia or cardioversion for atrial fibrillation within the past month, or paroxysmal atrial fibrillation requiring new pharmacologic therapy within the past month
- Systolic blood pressure consistently above 170 mmHg or consistently below 80 mmHg
- Supine resting heart rate exceeding 100 bpm
- Receiving continuous IV infusion of positive inotropic therapy or intermittent therapy (IV infusion) more than twice per week
- Heart transplant recipient
- Primary pulmonary disease of a severity that might limit the patient's ability to perform a treadmill test
- Serum creatinine above 3.0 mg/dL
- Serum hepatic functions at or above three times the upper normal limit
- Cerebrovascular event within the previous three months
- Inability to walk or other physical impediments which might prevent the patient from completing a maximum, symptom-limited treadmill test
- Age of less than 18 years
- Pregnancy
Studie plan
Hoe is de studie opgezet?
Medewerkers en onderzoekers
Sponsor
Studie record data
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Schatting)
Updates van studierecords
Laatste update geplaatst (Schatting)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- ITAC06
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .
Klinische onderzoeken op Ovatio CRT
-
LivaNovaVoltooidBiventriculaire tachycardieFrankrijk, Italië, Verenigd Koninkrijk, Duitsland, Portugal, België, Canada, Spanje, Zweden
-
LivaNovaVoltooidTachycardieFrankrijk, Duitsland, Portugal, Italië, Canada, Verenigde Staten, België, Nederland, Verenigd Koninkrijk
-
ELA Medical, Inc.VoltooidPlotselinge hartdoodVerenigde Staten
-
Children's Hospital of PhiladelphiaThe Hilda & Preston Davis FoundationVoltooid
-
Medtronic Cardiac Rhythm and Heart FailureMedtronicVoltooid
-
Inova Health Care ServicesMedtronicActief, niet wervendLinker bundeltakblok | Hartfalen (HF) | Linker ventriculaire ejectiefractieVerenigde Staten
-
Medtronic Cardiac Rhythm and Heart FailureVoltooidHartziekten | Atrioventriculair blokVerenigde Staten, Canada
-
Guy's and St Thomas' NHS Foundation TrustKing's College LondonNog niet aan het werven
-
University Hospital OlomoucNog niet aan het werven
-
Universidad Complutense de MadridVoltooidProgressie van bijziendheidSpanje