Clinical Evaluation of Cardiac Resynchronization Therapy (CRT) Using the Ovatio CRT Implantable Cardioverter-defibrillator (ICD) System
Clinical Evaluation of Cardiac Resynchronization Therapy With Implantable Cardioverter-defibrillator Therapy
This study provides a continued access registry for cardiac resynchronization therapy with defibrillation (CRT-D), which helps to resynchronize (coordinate) the rhythm of the heart by helping the left ventricle contract (pump blood) more uniformly, in patients with severe heart failure (New York Heart Association [NYHA] Class III or IV).
Quality of life, adverse events and device success will be analyzed and reported.
Przegląd badań
Status
Interwencja / Leczenie
Szczegółowy opis
ICDs have been shown to increase life expectancy substantially over various drug regimens in patients with life threatening ventricular arrhythmias. Furthermore, large scale studies of cardiac resynchronization therapy in ICD-indicated heart failure patients have demonstrated improvements in functional capacity and quality of life, without unacceptable increases in morbidity or mortality.
This study provides a continued access registry for cardiac resynchronization therapy with defibrillation (CRT-D), which helps to resynchronize (coordinate) the rhythm of the heart by helping the left ventricle contract (pump blood) more uniformly, in patients with severe heart failure (NYHA Class III or IV).
Quality of life, adverse events and device success will be analyzed and reported.
Typ studiów
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- Accepted indication for ICD implant
- Severe heart failure (NYHA Class III or IV) at the time of enrollment
- May have pre-existing ICD, provided subject is on stable, optimal medical regime
- Sinus rhythm with spontaneous QRS duration greater than or equal to 150 ms, or a QRS duration greater than or equal to 130 ms with an inter-ventricular mechanical delay (IVMD) greater than or equal to 40 ms
- Left-ventricular ejection fraction (LVEF) of 35% or less
Exclusion Criteria:
- Any generally accepted indication for standard cardiac pacing, or any contraindication for standard cardiac pacing
- Any contraindication for ICD therapy
- Currently implanted with a lead positioned in or through the coronary sinus
- Hypertrophic or obstructive cardiomyopathy
- Acute myocarditis
- Unstable coronary symptoms (unstable angina or myocardial infarction) within the last month
- Recent or planned cardiac revascularization or coronary angioplasty
- Correctable valvular disease that is the primary cause of heart failure
- Mechanical tricuspid valve
- Chronic atrial arrhythmia or cardioversion for atrial fibrillation within the past month, or paroxysmal atrial fibrillation requiring new pharmacologic therapy within the past month
- Systolic blood pressure consistently above 170 mmHg or consistently below 80 mmHg
- Supine resting heart rate exceeding 100 bpm
- Receiving continuous IV infusion of positive inotropic therapy or intermittent therapy (IV infusion) more than twice per week
- Heart transplant recipient
- Primary pulmonary disease of a severity that might limit the patient's ability to perform a treadmill test
- Serum creatinine above 3.0 mg/dL
- Serum hepatic functions at or above three times the upper normal limit
- Cerebrovascular event within the previous three months
- Inability to walk or other physical impediments which might prevent the patient from completing a maximum, symptom-limited treadmill test
- Age of less than 18 years
- Pregnancy
Plan studiów
Jak projektuje się badanie?
Współpracownicy i badacze
Sponsor
Daty zapisu na studia
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Oszacować)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Oszacować)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- ITAC06
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .
Badania kliniczne na Ovatio CRT
-
LivaNovaZakończonyTachykardie dwukomoroweFrancja, Włochy, Zjednoczone Królestwo, Niemcy, Portugalia, Belgia, Kanada, Hiszpania, Szwecja
-
ELA Medical, Inc.ZakończonyNagła śmierć sercowaStany Zjednoczone
-
LivaNovaZakończonyCzęstoskurczFrancja, Niemcy, Portugalia, Włochy, Kanada, Stany Zjednoczone, Belgia, Holandia, Zjednoczone Królestwo
-
Children's Hospital of PhiladelphiaThe Hilda & Preston Davis FoundationZakończonyJadłowstręt psychicznyStany Zjednoczone
-
Guy's and St Thomas' NHS Foundation TrustKing's College LondonJeszcze nie rekrutacja
-
University Hospital OlomoucJeszcze nie rekrutacjaKardiomiopatia rozstrzeniowa, 3BCzechy
-
CMC Ambroise ParéWycofanePorównanie dwóch metod programowania urządzeń CRT u pacjentów z niewydolnością serca ze wskazaniem do terapii resynchronizującej serceMonako, Francja
-
Medtronic Cardiac Rhythm and Heart FailureZakończonyChoroby serca | Blok przedsionkowo-komorowyStany Zjednoczone, Kanada
-
Inova Health Care ServicesMedtronicAktywny, nie rekrutującyLewy blok odnogi pęczka Hisa | Niewydolność serca (HF) | Frakcja wyrzutowa lewej komoryStany Zjednoczone
-
Medtronic Cardiac Rhythm and Heart FailureZakończonyZastoinowa niewydolność serca | Skurczowa niewydolność serca | Blok lewej odnogi pęczka HisaStany Zjednoczone, Szwecja, Indie, Federacja Rosyjska, Zjednoczone Królestwo