Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

Closing the Loop in Youth With Type 1 Diabetes in the Home Setting

22 september 2013 bijgewerkt door: Dr Roman Hovorka, University of Cambridge

An Open-label, Single-centre, Randomised, 2-period Cross-over Study to Assess the Efficacy, Safety and Utility of Real-time Continuous Subcutaneous Glucose Monitoring Combined With Overnight Closed-loop Glucose Control in the Home Setting in Comparison With Real-time Continuous Subcutaneous Glucose Monitoring Alone in Adolescents With Type 1 Diabetes on Subcutaneous Insulin Infusion Pump Therapy.

Type 1 diabetes (T1D) is one of the most common chronic childhood diseases requiring life-long insulin therapy. Children and adolescents with T1D need regular insulin injections or the continuous insulin delivery using an insulin pump in order to keep blood glucose levels normal. The investigators know that keeping blood sugars in the normal range will help prevent long-term diabetes-related complications involving the eyes, kidneys and heart. However, achieving treatment goals can be very difficult as the tighter the investigators try to control blood glucose levels, the greater the risk to develop symptoms and signs of low glucose levels (hypoglycaemia). This is a particular problem at night and one solution is to develop a system whereby the amount of insulin injected is controlled by a computer and is very closely matched to the blood sugar levels on a continuous basis. This can be achieved by what is known as a "closed-loop system" where a small glucose sensor placed under the skin communicates with a computer containing an algorithm that drives an insulin pump. The investigators have been testing such a system in Cambridge over the last three years in children and have found that this system is effective at preventing nocturnal hypoglycaemia. The next stage of this research is to test the system for a longer period of time at home. In the present study the investigators are planning to study 16 adolescents aged 12-18 years on insulin pump therapy. During 21 nights glucose will be controlled by the computer and during the other 21 nights the subjects will make their own adjustments to the insulin therapy. The investigators will then analyze the data to determine the effect of the computer algorithm in keeping glucose levels between 3.9 and 8 mmol/L (normal levels) and reducing the time they spent with glucose below 3.9 mmol/L (hypoglycaemia). Subjects' response to the use of the system in terms of life-style change, daily diabetes management and fear of hypoglycaemia will be assessed. The investigators will also test for longer term glucose control by measuring glycated haemoglobin and other blood parameters.

Studie Overzicht

Toestand

Voltooid

Conditie

Interventie / Behandeling

Studietype

Ingrijpend

Inschrijving (Werkelijk)

17

Fase

  • Fase 2

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

    • Cambridgeshire
      • Cambridge, Cambridgeshire, Verenigd Koninkrijk, CB2 0QQ
        • Department of Paediatrics, Weston paediatric diabetes centre

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

12 jaar tot 18 jaar (Kind, Volwassen)

Accepteert gezonde vrijwilligers

Nee

Geslachten die in aanmerking komen voor studie

Allemaal

Beschrijving

Inclusion Criteria:

  1. The subject is between 12 and 18 years of age (inclusive)
  2. The subject has type 1 diabetes, as defined by WHO for at least 1 year or is confirmed C-peptide negative
  3. The subject will all have been insulin pump user for at least 3 months, with good knowledge of insulin self-adjustment as judged by the investigator
  4. The subject willing to perform regular finger-prick blood glucose monitoring, with at least 4 blood glucose measurements taken every day
  5. HbA1c ≤ 10 % based on analysis from central laboratory or equivalent
  6. The subject is literate in English
  7. Able to accommodate on site or in close proximity member(s) of study team for supervised closed-loop night(s)

Exclusion Criteria:

  1. Non-type 1 diabetes mellitus including those secondary to chronic disease
  2. Any other physical or psychological disease likely to interfere with the normal conduct of the study and interpretation of the study results as judged by the investigator
  3. Current treatment with drugs known to interfere with glucose metabolism, eg systemic corticosteroids, non-selective beta-blockers and MAO inhibitors etc
  4. Known or suspected allergy against insulin
  5. Subjects with clinical significant nephropathy, neuropathy or proliferative retinopathy as judged by the investigator
  6. Total daily insulin dose ≥ 2 IU/kg/day
  7. Pregnancy, planned pregnancy, or breast feeding
  8. Prolonged use of any continuous glucose monitoring devices over the last 1 month prior the study
  9. Severe visual impairment
  10. Severe hearing impairment
  11. Subjects using implanted internal pace-maker -

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Behandeling
  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Crossover-opdracht
  • Masker: Geen (open label)

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Actieve vergelijker: Overnight closed-loop combined with real-time CGM
The closed-loop system is purpose-built and comprises a hand-held computer containing the algorithm and communicating with the CGM device and the insulin pump.
Actieve vergelijker: Real-time CGM alone
The closed-loop system is purpose-built and comprises a hand-held computer containing the algorithm and communicating with the CGM device and the insulin pump.

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Primary Efficacy Outcome
Tijdsspanne: At least 7 days of valid CGM nights (midnight-7:30)
The primary objective of the study is to assess the efficacy of continuous glucose monitoring (CGM) combined with overnight automated closed-loop glucose control in maintaining CGM glucose levels within the target range from 3.9 to 8.0 mmol/L, when compared with the use of CGM alone in the home setting.
At least 7 days of valid CGM nights (midnight-7:30)

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Secondary outcomes
Tijdsspanne: At least 7 days of valid CGM nights (midnight-7:30)

As a secondary research question, the safety of overnight automated closed-loop glucose control in terms of number of episodes of severe hypoglycaemia as well as the number of subjects experiencing severe hypoglycaemia and other adverse events.

Furthermore, the frequency and duration of use of the closed-loop system will be evaluated. Subjects' perception in terms of life-style change, daily diabetes management and fear of hypoglycaemia will be assessed using questionnaires and a qualitative interview.

At least 7 days of valid CGM nights (midnight-7:30)

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Publicaties en nuttige links

De persoon die verantwoordelijk is voor het invoeren van informatie over het onderzoek stelt deze publicaties vrijwillig ter beschikking. Dit kan gaan over alles wat met het onderzoek te maken heeft.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start

1 juni 2012

Primaire voltooiing (Werkelijk)

1 maart 2013

Studie voltooiing (Werkelijk)

1 maart 2013

Studieregistratiedata

Eerst ingediend

14 oktober 2010

Eerst ingediend dat voldeed aan de QC-criteria

14 oktober 2010

Eerst geplaatst (Schatting)

15 oktober 2010

Updates van studierecords

Laatste update geplaatst (Schatting)

24 september 2013

Laatste update ingediend die voldeed aan QC-criteria

22 september 2013

Laatst geverifieerd

1 september 2013

Meer informatie

Termen gerelateerd aan deze studie

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren