Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Closing the Loop in Youth With Type 1 Diabetes in the Home Setting

22 de septiembre de 2013 actualizado por: Dr Roman Hovorka, University of Cambridge

An Open-label, Single-centre, Randomised, 2-period Cross-over Study to Assess the Efficacy, Safety and Utility of Real-time Continuous Subcutaneous Glucose Monitoring Combined With Overnight Closed-loop Glucose Control in the Home Setting in Comparison With Real-time Continuous Subcutaneous Glucose Monitoring Alone in Adolescents With Type 1 Diabetes on Subcutaneous Insulin Infusion Pump Therapy.

Type 1 diabetes (T1D) is one of the most common chronic childhood diseases requiring life-long insulin therapy. Children and adolescents with T1D need regular insulin injections or the continuous insulin delivery using an insulin pump in order to keep blood glucose levels normal. The investigators know that keeping blood sugars in the normal range will help prevent long-term diabetes-related complications involving the eyes, kidneys and heart. However, achieving treatment goals can be very difficult as the tighter the investigators try to control blood glucose levels, the greater the risk to develop symptoms and signs of low glucose levels (hypoglycaemia). This is a particular problem at night and one solution is to develop a system whereby the amount of insulin injected is controlled by a computer and is very closely matched to the blood sugar levels on a continuous basis. This can be achieved by what is known as a "closed-loop system" where a small glucose sensor placed under the skin communicates with a computer containing an algorithm that drives an insulin pump. The investigators have been testing such a system in Cambridge over the last three years in children and have found that this system is effective at preventing nocturnal hypoglycaemia. The next stage of this research is to test the system for a longer period of time at home. In the present study the investigators are planning to study 16 adolescents aged 12-18 years on insulin pump therapy. During 21 nights glucose will be controlled by the computer and during the other 21 nights the subjects will make their own adjustments to the insulin therapy. The investigators will then analyze the data to determine the effect of the computer algorithm in keeping glucose levels between 3.9 and 8 mmol/L (normal levels) and reducing the time they spent with glucose below 3.9 mmol/L (hypoglycaemia). Subjects' response to the use of the system in terms of life-style change, daily diabetes management and fear of hypoglycaemia will be assessed. The investigators will also test for longer term glucose control by measuring glycated haemoglobin and other blood parameters.

Descripción general del estudio

Estado

Terminado

Condiciones

Intervención / Tratamiento

Tipo de estudio

Intervencionista

Inscripción (Actual)

17

Fase

  • Fase 2

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

    • Cambridgeshire
      • Cambridge, Cambridgeshire, Reino Unido, CB2 0QQ
        • Department of Paediatrics, Weston paediatric diabetes centre

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

12 años a 18 años (Niño, Adulto)

Acepta Voluntarios Saludables

No

Géneros elegibles para el estudio

Todos

Descripción

Inclusion Criteria:

  1. The subject is between 12 and 18 years of age (inclusive)
  2. The subject has type 1 diabetes, as defined by WHO for at least 1 year or is confirmed C-peptide negative
  3. The subject will all have been insulin pump user for at least 3 months, with good knowledge of insulin self-adjustment as judged by the investigator
  4. The subject willing to perform regular finger-prick blood glucose monitoring, with at least 4 blood glucose measurements taken every day
  5. HbA1c ≤ 10 % based on analysis from central laboratory or equivalent
  6. The subject is literate in English
  7. Able to accommodate on site or in close proximity member(s) of study team for supervised closed-loop night(s)

Exclusion Criteria:

  1. Non-type 1 diabetes mellitus including those secondary to chronic disease
  2. Any other physical or psychological disease likely to interfere with the normal conduct of the study and interpretation of the study results as judged by the investigator
  3. Current treatment with drugs known to interfere with glucose metabolism, eg systemic corticosteroids, non-selective beta-blockers and MAO inhibitors etc
  4. Known or suspected allergy against insulin
  5. Subjects with clinical significant nephropathy, neuropathy or proliferative retinopathy as judged by the investigator
  6. Total daily insulin dose ≥ 2 IU/kg/day
  7. Pregnancy, planned pregnancy, or breast feeding
  8. Prolonged use of any continuous glucose monitoring devices over the last 1 month prior the study
  9. Severe visual impairment
  10. Severe hearing impairment
  11. Subjects using implanted internal pace-maker -

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

  • Propósito principal: Tratamiento
  • Asignación: Aleatorizado
  • Modelo Intervencionista: Asignación cruzada
  • Enmascaramiento: Ninguno (etiqueta abierta)

Armas e Intervenciones

Grupo de participantes/brazo
Intervención / Tratamiento
Comparador activo: Overnight closed-loop combined with real-time CGM
The closed-loop system is purpose-built and comprises a hand-held computer containing the algorithm and communicating with the CGM device and the insulin pump.
Comparador activo: Real-time CGM alone
The closed-loop system is purpose-built and comprises a hand-held computer containing the algorithm and communicating with the CGM device and the insulin pump.

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Primary Efficacy Outcome
Periodo de tiempo: At least 7 days of valid CGM nights (midnight-7:30)
The primary objective of the study is to assess the efficacy of continuous glucose monitoring (CGM) combined with overnight automated closed-loop glucose control in maintaining CGM glucose levels within the target range from 3.9 to 8.0 mmol/L, when compared with the use of CGM alone in the home setting.
At least 7 days of valid CGM nights (midnight-7:30)

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Secondary outcomes
Periodo de tiempo: At least 7 days of valid CGM nights (midnight-7:30)

As a secondary research question, the safety of overnight automated closed-loop glucose control in terms of number of episodes of severe hypoglycaemia as well as the number of subjects experiencing severe hypoglycaemia and other adverse events.

Furthermore, the frequency and duration of use of the closed-loop system will be evaluated. Subjects' perception in terms of life-style change, daily diabetes management and fear of hypoglycaemia will be assessed using questionnaires and a qualitative interview.

At least 7 days of valid CGM nights (midnight-7:30)

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio

1 de junio de 2012

Finalización primaria (Actual)

1 de marzo de 2013

Finalización del estudio (Actual)

1 de marzo de 2013

Fechas de registro del estudio

Enviado por primera vez

14 de octubre de 2010

Primero enviado que cumplió con los criterios de control de calidad

14 de octubre de 2010

Publicado por primera vez (Estimar)

15 de octubre de 2010

Actualizaciones de registros de estudio

Última actualización publicada (Estimar)

24 de septiembre de 2013

Última actualización enviada que cumplió con los criterios de control de calidad

22 de septiembre de 2013

Última verificación

1 de septiembre de 2013

Más información

Términos relacionados con este estudio

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir