- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT02095678
Assessment of Novel MRI Quantification Free Breathing Technique in Evaluation of Liver Lesions
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Gedetailleerde beschrijving
Studietype
Inschrijving (Werkelijk)
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
Ohio
-
Cleveland, Ohio, Verenigde Staten, 44106
- University Hospitals Cleveland Medical Center, Case Comprehensive Cancer Center
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- No contraindications to getting contrast enhanced MRI examinations.
- GFR ≥ 40.
Exclusion Criteria:
- Patients with ferromagnetic or otherwise non-MRI compatible aneurysm clips.
- The presence of an implanted pacemaker or implanted defibrillator device
- Patients with contraindications for MRI due to embedded foreign metallic objects. Bullets, shrapnel, metalwork fragments, or other metallic material adds unnecessary risk to the patient.
- Pregnancy. Regular clinical practice already excludes pregnant patients from gadolinium contrast due to unknown effects on the fetus. The current clinical practice will be applied - patients will be verbally screened and asked if they think they could be pregnant. If the answer is yes, then the patient will be excluded from the study. If the patient is uncertain about the pregnancy status, she will be given an option to undergo a pregnancy test or not participate in the study altogether. Patients who self report that they are not pregnant will be allowed to participate in the study. This procedure is based on current department policy guidelines.
- Implanted medical device not described above that is not MRI-compatible;
- Known history of claustrophobia;
- Known history of allergic reaction to Magnetic Resonance contrast material;
- Late stage renal failure with estimated glomerular filtration rate (eGFR) of less than 30 mL/min/1.73 m2 based on patient's serum creatinine due to the significantly increased risk of nephrogenic systemic fibrosis (NSF). ('Past' 3 months timeframe will be used to calculate the eGRF).
- Minors will be excluded.
- Prisoners and members of other vulnerable populations will be excluded from this study. The subject selection population will not regularly include prisoners and other vulnerable population members as these populations will not provide any additional unique information to or uniquely benefit from the study. Non-english speaking population will be excluded from the study due to lack of sufficient resources to pay for translator and interpreter services.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Diagnostisch
- Toewijzing: Niet-gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: HCC or metastatic Liver Lesions
Patients with HCC or metastatic liver lesions who are refered to the abdominal imaging and biopsy clinic will have a liver biopsy performed.
3-5 days after a clinical MRI indicating a cancerous lesion, patients will return for the free-breathing MRI and a liver biopsy.
These images will be compared to the clinical MRI and to images of the benign lesions.
|
patients with HCC or metastatic lesions will have a liver biopsy performed after the experimental MRI.
This biopsy will be examined to confirm the imaging results
All patients will be asked to come in for an MRI scan using techniques developed which minimize the time a patient has to hold their breath to image the liver to <8 seconds and validate quantifiable techniques which improve liver image quality
Andere namen:
|
|
Actieve vergelijker: Benign Liver Lesion
Patients with benign liver lesions will be referred to the study team.
3-5 days after a clinical MRI an experimental, free-breathing MRI will be performed on these patients.
The results will be compared to their clinical MRI images and to images of HCC or metastatic lesions
|
All patients will be asked to come in for an MRI scan using techniques developed which minimize the time a patient has to hold their breath to image the liver to <8 seconds and validate quantifiable techniques which improve liver image quality
Andere namen:
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Arterial Fraction
Tijdsspanne: 1 day, At time of Research MRI
|
Dynamic Contrast Enhanced MRI data were used to calculate three quantitative perfusion properties using a dual input, single tissue compartment model of gadolinium based contrast agents in the liver in HCC, metastatic, and benign lesions. One of these quantitative perfusion properties is Mean Arterial fraction, which is the proportion of blood flow derived from hepatic artery. |
1 day, At time of Research MRI
|
|
Distribution Volume (DV)
Tijdsspanne: 1 day, At time of Research MRI
|
Dynamic Contrast Enhanced MRI data were used to calculate three quantitative perfusion properties using a dual input, single tissue compartment model of gadolinium based contrast agents in the liver in HCC, metastatic, and benign lesions. One of these quantitative perfusion properties is DV. DV corresponds to the volume of extracellular, extravascular space in a tissue which is a measure of the tissue cellularity |
1 day, At time of Research MRI
|
|
Mean Transit Time (MTT)
Tijdsspanne: 1 day, At time of Research MRI
|
Dynamic Contrast Enhanced MRI data were used to calculate three quantitative perfusion properties using a dual input, single tissue compartment model of gadolinium based contrast agents in the liver in HCC, metastatic, and benign lesions. One of these quantitative perfusion properties is MTT. MTT corresponds to the average time, in seconds, that red blood cells spend within a determinate volume of capillary circulation |
1 day, At time of Research MRI
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Free Breathing Quantification of Relaxation Parameters
Tijdsspanne: Up to 1 year
|
Quantified and validated relaxation parameters when creating T1 (spin-lattice) and T2 (spin-spin) weighted images
|
Up to 1 year
|
|
Minimal Breathhold Time
Tijdsspanne: 1 year
|
The minimum time (in seconds) a patient must hold their breath to produce quality liver images during an MRI.
Developing and validating a minimal breath-hold (< 8 s) high quality diffusion exam using highly accelerated steady state diffusion imaging sequences.
|
1 year
|
Medewerkers en onderzoekers
Sponsor
Onderzoekers
- Hoofdonderzoeker: Vikas Gulani, MD, Case Comprehensive Cancer Center
Publicaties en nuttige links
Studie record data
Bestudeer belangrijke data
Studie start
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Schatting)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- CASE3213
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
product vervaardigd in en geëxporteerd uit de V.S.
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .