- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT02368977
Third Eye Panoramic Device Feasibility Evaluation
This study will evaluate the feasibility of using the Third Eye Panoramic device in conjunction with standard colonoscopes in a clinical setting.
Patients will undergo a colonoscopy procedure during which the study device will provide video imaging of areas of the colon that are difficult to evaluate with the colonoscope alone.
The utility of the device will be assessed from the impressions of the investigators and from telephone follow-up with subjects to assess for post-procedural complications.
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Gedetailleerde beschrijving
The purpose of this study is to evaluate the feasibility of using the Third Eye Panoramic device along with a standard colonoscope as a means of enhancing the ability of endoscopists to view areas that are hidden from the view of the colonoscope.
Colonoscopy is generally agreed to be the best method for detecting and removing cancers and pre-cancerous adenomas in the colon. However, numerous studies have demonstrated that from 22% to over 40% of adenomas are missed during standard colonoscopy. More importantly, 12% of large adenomas (at least 1 cm) are missed even by expert endoscopists using meticulous technique with the best available equipment, and these large adenomas are the ones that are most likely to transform into cancer.
Factors such as quality of bowel cleansing and time spent examining the colonic mucosa have been shown to affect miss rates. However, comparison with the results of CT colonography has shown that 2/3 of missed adenomas are located behind folds in the wall of the colon, in areas that are very difficult to see with a standard forward-viewing colonoscope.
When clipped onto the tip of a standard colonoscope, the Third Eye Panoramic device provides two additional miniature video cameras and light sources that offer views to the left side and right side of the colonoscope's tip. These lateral views complement the forward view of the colonoscope's camera to result in a "panoramic" view of over 300°. This extreme wide-angle view allows the endoscopist to examine the areas located behind folds.
In this study, each subject will undergo a colonoscopy procedure utilizing the Third Eye Panoramic device along with a standard colonoscope.
The investigators will evaluate issues related to usability and safety based on their experience and impressions, with telephone follow-up with subjects to assess for any post-procedural complications.
Studietype
Inschrijving (Verwacht)
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
New York
-
Flushing, New York, Verenigde Staten, 11355
- New York Hospital Queens
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- The patient is undergoing colonoscopy for screening, for surveillance in follow-up of previous polypectomy or for diagnostic workup.
- The patient must understand and provide written consent for the procedure.
Exclusion Criteria:
- Patients >75 years of age;
- Patients with a history of colonic resection;
- Patients with suspected chronic stricture potentially precluding complete colonoscopy;
- Patients with diverticulitis or toxic megacolon;
- Patients with a history of radiation therapy to abdomen or pelvis;
- Patients who are currently enrolled in another clinical investigation in which the intervention might compromise the safety of the patient's participation in this study.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Diagnostisch
- Toewijzing: NVT
- Interventioneel model: Opdracht voor een enkele groep
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: All subjects
All subjects will undergo examination with a Third Eye Panoramic device in conjunction with a standard colonoscope to evaluate the feasibility of using the study device to provide video imaging of areas of the colon that are difficult to evaluate with the colonoscope alone.
|
A Third Eye Panoramic device will be attached to the tip of the colonoscope and will provide two additional views from laterally-oriented video cameras during the colonoscopy procedure.
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Device usability factors
Tijdsspanne: 1 hour (average duration of procedure)
|
Device usability as measured by investigators' qualitative impressions regarding ease of use and any potential interference with function of colonoscope.
|
1 hour (average duration of procedure)
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Device video factors
Tijdsspanne: 1 hour (average duration of procedure)
|
Video image quality and ability to view areas behind folds as measured by investigators' qualitative impressions
|
1 hour (average duration of procedure)
|
|
Patient safety assessed by number of subjects with adverse events as a measure of safety and tolerability
Tijdsspanne: At time of procedure and up to 48 hours after completion of procedure
|
Number of subjects with adverse events
|
At time of procedure and up to 48 hours after completion of procedure
|
Medewerkers en onderzoekers
Sponsor
Onderzoekers
- Hoofdonderzoeker: Moshe Rubin, MD, New York Hospital Queens - Weill Cornell Medical College
Publicaties en nuttige links
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Verwacht)
Studie voltooiing (Verwacht)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Schatting)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- Avantis TEP 13-01
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .