Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

Use of TEE Derived Measurement vs Direct Measurement Under General Anesthesia in Assessment of Pressure Gradient in Peri Membranous Ventricular Septal Defect

17 juni 2026 bijgewerkt door: Ain Shams University
In this study, the investigators aim to compare the pressure gradient obtained by transesophageal echocardiography across the restrictive peri membranous VSD with direct catheter-based measurements of such gradient.

Studie Overzicht

Toestand

Nog niet aan het werven

Gedetailleerde beschrijving

Ventricular septal defect is the most common congenital heart defect, occurring in 50% of all children with congenital heart disease (CHD) and in 20% as an isolated lesion.

The peri membranous (also called Para membranous or Cono ventricular) VSD is a communication adjacent to a portion of the membranous septum and the fibrous trigone of the heart, where the, and tricuspid valves are in fibrous continuity. These infracristal defects (below the crista supra- ventricularis) are the most common VSD subtype, accounting for approximately 80% of VSDs.

The ventricular septum can be well imaged by TEE. Starting from the standard transverse plane at 0° or so in the mi esophageal four-chamber (ME 4-Ch) view, the crux of the heart, the inlet septum and most of the muscular trabecular septum can be well seen from the AV valves down to the apex.

In this study, the investigators aim to compare the pressure gradient obtained by transesophageal echocardiography across the restrictive peri membranous VSD with direct catheter-based measurements of such gradient.

During the pre-anesthetic evaluation, demographic variables will be collected from each patient. ASA physical status and relevant comorbidities will be documented, and a recent echocardiogram will confirm the presence of VSD, its size, pressure gradient and estimated PAP.

Patients will be taken to the operating room and monitored with ASA standard monitors: ECG, NIBP, pulse oximetry, and capnography. Preoxygenation will be performed with FiO₂ adjusted to maintain normal oxygen saturation Anesthesia inhalational induction will be performed with sevoflurane until IV access is secured. Once IV access is established, transition to IV agents, fentanyl (1-2 mcg/kg), and rocuronium (0.8 mg/kg). Ventilation with oxygen and sevoflurane 1.5% for 3 min.

Direct laryngoscopy and intubation will be performed by an attending anesthesiologist (with more than two years of experience post-qualification) along with femoral arterial and venous line along with internal jugular central venous line insertion.

Using the previously inserted lines, the pressure gradient across VSD along with RVSP and PASP are directly measured using catheters under guidance of fluoroscopy along with the hemodynamics it was obtained with. This entails that this should be performed in a hybrid theatre otherwise, the confirmation of catheter placement by TEE should be done. TEE inserted in the same setup under the same hemodynamics, RV inflow outflow view obtained with best alignment for CWD interrogation and pressure gradient obtained along with its respective hemodynamics, this step is to be repeated with different personnel with different levels of experience. Care should be taken that both measurements should be taken with the same hemodynamics. TEE measurements of pressure gradient across the VSD are to be measured in the ME five chamber view and ME aorta long axis view as well.

The surgeon will then perform median sternotomy, cpb cannulation, VSD repair. Any considerable events during weaning from cpb shall be recorded along with the doses needed for vasopressors and inotropic support. TEE post bypass will be done by senior attending confirming VSD closure, RV function and PAP if possible.

Studietype

Observationeel

Inschrijving (Geschat)

115

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studiecontact

Studie Locaties

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Kind

Accepteert gezonde vrijwilligers

Nee

Bemonsteringsmethode

Niet-waarschijnlijkheidssteekproef

Studie Bevolking

The study will include pediatric patients aged 6 months to 5 years diagnosed with isolated peri membranous ventricular septal defect (VSD) who are scheduled for elective surgical VSD closure under general anesthesia. All patients will undergo intraoperative assessment of the pressure gradient across the VSD using both transesophageal echocardiography (TEE)-derived measurements and direct intraoperative measurement techniques.

Patients with other types of VSD, unrestrictive VSD, associated pulmonary vascular disease, recent or active upper respiratory tract infection, or any relative or absolute contraindication to TEE will be excluded. Informed consent will be obtained from legal guardians prior to enrollment.

Beschrijving

Inclusion Criteria:

  • Pediatric patients (6 months to 5 years).
  • Patients with isolated peri-membranous VSD.
  • Scheduled for surgical VSD closure.

Exclusion Criteria:

  • Refusal of legal guardians.
  • Patients with other types of VSD.
  • Patients with pulmonary vascular diseases.
  • Patients with unrestrictive VSD.
  • Recent or active upper respiratory tract infection.
  • Any relative or absolute contraindication for TEE.

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

Cohorten en interventies

Groep / Cohort
TEE derived measurement vs direct catheter measurement
Pediatric patients with isolated peri membranous VSD undergoing surgical closure will undergo intraoperative pressure gradient assessment using both TEE-derived and direct catheter-based measurements under general anesthesia

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Accuracy of TEE-derived pressure gradient measurement across peri membranous VSD
Tijdsspanne: intraoperative
Accuracy of TEE derived Pressure gradient in numerical value across peri membranous VSD (in Rv inflow outflow view) in comparison with direct catheter-based measurements under general anesthesia.
intraoperative

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Accuracy of TEE-derived RVSP and PASP measurements
Tijdsspanne: intraoperative
Comparison between TEE-derived RVSP/PASP and direct catheter-based measurements under general anesthesia.
intraoperative
Interrater agreement of TEE measurements
Tijdsspanne: intraoperative
Assessment of agreement between different operators with different levels of experience regarding TEE image acquisition and TEE derived measurements.
intraoperative

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Geschat)

27 mei 2026

Primaire voltooiing (Geschat)

20 januari 2027

Studie voltooiing (Geschat)

20 april 2027

Studieregistratiedata

Eerst ingediend

28 mei 2026

Eerst ingediend dat voldeed aan de QC-criteria

28 mei 2026

Eerst geplaatst (Werkelijk)

3 juni 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

22 juni 2026

Laatste update ingediend die voldeed aan QC-criteria

17 juni 2026

Laatst geverifieerd

1 mei 2026

Meer informatie

Termen gerelateerd aan deze studie

Andere studie-ID-nummers

  • FMASU MD358/2025

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

ONBESLIST

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren