- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT07623330
Use of TEE Derived Measurement vs Direct Measurement Under General Anesthesia in Assessment of Pressure Gradient in Peri Membranous Ventricular Septal Defect
Visão geral do estudo
Status
Descrição detalhada
Ventricular septal defect is the most common congenital heart defect, occurring in 50% of all children with congenital heart disease (CHD) and in 20% as an isolated lesion.
The peri membranous (also called Para membranous or Cono ventricular) VSD is a communication adjacent to a portion of the membranous septum and the fibrous trigone of the heart, where the, and tricuspid valves are in fibrous continuity. These infracristal defects (below the crista supra- ventricularis) are the most common VSD subtype, accounting for approximately 80% of VSDs.
The ventricular septum can be well imaged by TEE. Starting from the standard transverse plane at 0° or so in the mi esophageal four-chamber (ME 4-Ch) view, the crux of the heart, the inlet septum and most of the muscular trabecular septum can be well seen from the AV valves down to the apex.
In this study, the investigators aim to compare the pressure gradient obtained by transesophageal echocardiography across the restrictive peri membranous VSD with direct catheter-based measurements of such gradient.
During the pre-anesthetic evaluation, demographic variables will be collected from each patient. ASA physical status and relevant comorbidities will be documented, and a recent echocardiogram will confirm the presence of VSD, its size, pressure gradient and estimated PAP.
Patients will be taken to the operating room and monitored with ASA standard monitors: ECG, NIBP, pulse oximetry, and capnography. Preoxygenation will be performed with FiO₂ adjusted to maintain normal oxygen saturation Anesthesia inhalational induction will be performed with sevoflurane until IV access is secured. Once IV access is established, transition to IV agents, fentanyl (1-2 mcg/kg), and rocuronium (0.8 mg/kg). Ventilation with oxygen and sevoflurane 1.5% for 3 min.
Direct laryngoscopy and intubation will be performed by an attending anesthesiologist (with more than two years of experience post-qualification) along with femoral arterial and venous line along with internal jugular central venous line insertion.
Using the previously inserted lines, the pressure gradient across VSD along with RVSP and PASP are directly measured using catheters under guidance of fluoroscopy along with the hemodynamics it was obtained with. This entails that this should be performed in a hybrid theatre otherwise, the confirmation of catheter placement by TEE should be done. TEE inserted in the same setup under the same hemodynamics, RV inflow outflow view obtained with best alignment for CWD interrogation and pressure gradient obtained along with its respective hemodynamics, this step is to be repeated with different personnel with different levels of experience. Care should be taken that both measurements should be taken with the same hemodynamics. TEE measurements of pressure gradient across the VSD are to be measured in the ME five chamber view and ME aorta long axis view as well.
The surgeon will then perform median sternotomy, cpb cannulation, VSD repair. Any considerable events during weaning from cpb shall be recorded along with the doses needed for vasopressors and inotropic support. TEE post bypass will be done by senior attending confirming VSD closure, RV function and PAP if possible.
Tipo de estudo
Inscrição (Estimado)
Contactos e Locais
Contato de estudo
- Nome: karim mohammad el kersh, MBBCH
- Número de telefone: 01002123494
- E-mail: karim.elkersh@med.asu.edu.eg
Locais de estudo
-
-
Abbasia
-
Cairo, Abbasia, Egito, 00202
- Ain Shams
-
Contato:
- karim mohammad el kersh, MBBCH
- Número de telefone: 01002123494
- E-mail: karim.elkersh@med.asu.edu.eg
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
- Filho
Aceita Voluntários Saudáveis
Método de amostragem
População do estudo
The study will include pediatric patients aged 6 months to 5 years diagnosed with isolated peri membranous ventricular septal defect (VSD) who are scheduled for elective surgical VSD closure under general anesthesia. All patients will undergo intraoperative assessment of the pressure gradient across the VSD using both transesophageal echocardiography (TEE)-derived measurements and direct intraoperative measurement techniques.
Patients with other types of VSD, unrestrictive VSD, associated pulmonary vascular disease, recent or active upper respiratory tract infection, or any relative or absolute contraindication to TEE will be excluded. Informed consent will be obtained from legal guardians prior to enrollment.
Descrição
Inclusion Criteria:
- Pediatric patients (6 months to 5 years).
- Patients with isolated peri-membranous VSD.
- Scheduled for surgical VSD closure.
Exclusion Criteria:
- Refusal of legal guardians.
- Patients with other types of VSD.
- Patients with pulmonary vascular diseases.
- Patients with unrestrictive VSD.
- Recent or active upper respiratory tract infection.
- Any relative or absolute contraindication for TEE.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
Coortes e Intervenções
Grupo / Coorte |
|---|
|
TEE derived measurement vs direct catheter measurement
Pediatric patients with isolated peri membranous VSD undergoing surgical closure will undergo intraoperative pressure gradient assessment using both TEE-derived and direct catheter-based measurements under general anesthesia
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Accuracy of TEE-derived pressure gradient measurement across peri membranous VSD
Prazo: intraoperative
|
Accuracy of TEE derived Pressure gradient in numerical value across peri membranous VSD (in Rv inflow outflow view) in comparison with direct catheter-based measurements under general anesthesia.
|
intraoperative
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Accuracy of TEE-derived RVSP and PASP measurements
Prazo: intraoperative
|
Comparison between TEE-derived RVSP/PASP and direct catheter-based measurements under general anesthesia.
|
intraoperative
|
|
Interrater agreement of TEE measurements
Prazo: intraoperative
|
Assessment of agreement between different operators with different levels of experience regarding TEE image acquisition and TEE derived measurements.
|
intraoperative
|
Colaboradores e Investigadores
Patrocinador
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Estimado)
Conclusão Primária (Estimado)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Outros números de identificação do estudo
- FMASU MD358/2025
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .