Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

Validate Smart Breath Analyzer as Screening Tool for Diabetic, Hepatic, Renal, Lung, and Other Metabolic Disorders (RESPYR-SBA)

9 juni 2026 bijgewerkt door: Respyr

Early Identification of Metabolic Function Derangements Such as Diabetes, Liver, Renal Issues by Respyr Smart Breath Analyzer and Its Validation as a Screening Tool Among Diseased and Healthy Controls

This is a prospective, multicentric, non-treatment study to build and validate a portable, non-invasive smart breath analyzer that can screen underlying health issues using exhaled breath. The study will be conducted with healthy participants and participants with known cases of diabetes, kidney related issues, liver related issues, and lung related issues as confirmed by pathology reports. In phase 1, 500 apparently healthy individuals with normal levels of fasting and postprandial blood sugar, renal function test, liver function test, and lung function test will be recruited. In phase 2, 500 patients of type 2 diabetes, liver function, renal function, and lung function derangements each diagnosed by 10% increment above normal values will be enrolled. In phase 3, validation of the breath analyzer as a screening tool for early identification of type 2 diabetes, liver, renal, lung and other metabolic function derangements will be done by randomly assigning healthy and diseased participants for exhaled breath sample analysis. The study is based on the principle of exhaled breath analysis where parts per million and parts per billion level of volatile organic compounds and gases in human breath will be measured. AI based algorithms will be generated to effectively screen unhealthy biomarker levels, enabling timely preventive action.

Studie Overzicht

Gedetailleerde beschrijving

The smart breath analyzer, Respyr is an IoT and deep-tech enabled portable device developed by Humors Tech Pvt Ltd, Bangalore, India. The device measures volatile organic compounds (VOCs) and gases at parts-per-million and parts-per-billion levels in exhaled breath using AI and ML-based algorithms to identify metabolic derangements non-invasively.

Registration Details:

The study is registered with CTRI (CTRI/2022/09/045983) and ethics approval has been obtained from the Institutional Ethics Committee of JSS Medical College, Mysore (Ref: JSSMC/IEC/260822/07/CT Final Approval/2022-23, dated 19.12.2022). Protocol number: HTB-PROTOCOL-01, Version 1, dated 07 March 2022.

Testing Procedure:

Participants will provide an exhaled breath sample under fasting conditions, or with a minimum gap of 1 hour after consuming water and 3-4 hours after consuming food. The breath analyzer readings will be compared against standard laboratory diagnostic values including FBS/RBS, RFT, LFT, spirometry, and lipid profile, all tested within 15 days of participation.

Regulatory Compliance:

The study follows ICH-GCP guidelines, CDSCO-DCGI and New Drugs and Clinical Trial Rules 2019, and ICMR Ethical Guidelines for Biomedical Research on Human Participants.

Studietype

Observationeel

Inschrijving (Werkelijk)

3000

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

    • Karnataka
      • Mysore, Karnataka, Indië, 570015
        • Dept. of Community Medicine, JSS Medical College

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Volwassen
  • Oudere volwassene

Accepteert gezonde vrijwilligers

Ja

Bemonsteringsmethode

Niet-waarschijnlijkheidssteekproef

Studie Bevolking

Healthy volunteers and patients with confirmed metabolic disorders including type 2 diabetes, liver disease, kidney disease, and lung disease recruited from JSS Hospital and Medical College, Mysore, India.

Beschrijving

Inclusion Criteria:

  • Participant must either be a completely healthy individual as confirmed by blood examination, or a known case of diabetes, kidney disease, liver disease, and lung disease with relevant diagnostic reports tested within 15 days of participation
  • All genders and ethnicities
  • Age 18 to 75 years
  • Participant who has given informed consent
  • Participant must be fully vaccinated for COVID-19
  • Participant must use the smart breath analyzer at fasting condition; if not fasting, minimum gap of 1 hour after water and 3-4 hours after food

Exclusion Criteria:

  • Individual less than 18 or above 75 years of age
  • Pregnant and lactating females
  • Known case of ongoing illness such as Cancer, AIDS, COVID-19, Cough, Fever, TB, Chickenpox, Influenza, Mumps, or Tonsillitis
  • Individual who has not given informed consent

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

Cohorten en interventies

Groep / Cohort
Healthy Volunteers
Apparently healthy individuals aged 18-75 years with normal levels of fasting and postprandial blood sugar, renal function test, liver function test, and lung function test, as confirmed by blood examination conducted within 15 days of participation. Participants will undergo exhaled breath analysis using the Respyr smart breath analyzer device.
Patients with Metabolic Disorders
Patients aged 18-75 years with confirmed diagnosis of one or more metabolic disorders including type 2 diabetes (confirmed by FBS/RBS), kidney disease (confirmed by RFT), liver disease (confirmed by LFT), and lung disease (confirmed by spirometry), with relevant diagnostic reports tested within 15 days of participation. Participants will undergo exhaled breath analysis using the Respyr smart breath analyzer device.

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Validation of Smart Breath Analyzer for Screening of Metabolic Disorders
Tijdsspanne: Baseline
Development and validation of an IoT and deep-tech enabled smart breath analyzer for accurate and early screening of metabolic derangements including diabetes, kidney disease, liver disease, lung disease, AI and ML-based algorithms will be generated to provide an affordable, non-invasive screening option enabling timely preventive healthcare action
Baseline

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Triglycerides
Tijdsspanne: baseline
Measured in mg/dl. Normal range: <150 mg/dl. Compared with smart breath analyzer readings.
baseline
HDL
Tijdsspanne: baseline
Measured in mg/dl. Normal range: 40-60 mg/dl. Compared with smart breath analyzer readings.
baseline
VLDL
Tijdsspanne: Baseline
Measured in mg/dl. Normal range: 2-30 mg/dl. Compared with smart breath analyzer readings.
Baseline
LDL
Tijdsspanne: Baseline
Measured in mg/dl. Normal range: 100-129 mg/dl. Compared with smart breath analyzer readings.
Baseline
Cholesterol/ HDL Ratio
Tijdsspanne: Baseline
Ratio with no unit. Normal range: <4.5. Compared with smart breath analyzer readings.
Baseline
LDL/HDL Ratio
Tijdsspanne: Baseline
Ratio with no unit. Normal range: <3. Compared with smart breath analyzer readings.
Baseline
Serum Protein Level (Total Protein, Albumin, Globulin) assessed by Liver Function Test (LFT)
Tijdsspanne: Baseline
Measured in g/dl. Normal ranges: Total Protein 6.4-8.3 g/dl, Albumin 3.4-4.8 g/dl, Globulin 2-3.5 g/dl. Compared with smart breath analyzer readings.
Baseline
Serum Creatinine Level assessed by Renal Function Test (RFT)
Tijdsspanne: Baseline
Measured in mg/dl. Normal range: 0.7-1.3 mg/dl. Compared with smart breath analyzer readings.
Baseline
Fasting Blood Glucose Level assessed by Fasting Blood Sugar Test (FBS)
Tijdsspanne: Baseline
Measured in mg/dl. Normal range: 75-110 mg/dl. Compared with smart breath analyzer readings.
Baseline
HBA1C (4.0-5.6)
Tijdsspanne: Baseline
HbA1c Level assessed by Glycated Hemoglobin Test
Baseline
Post Prandial (<140)
Tijdsspanne: Baseline
Postprandial Blood Glucose Level assessed by Post Prandial Blood Sugar Test (PPBS)
Baseline
Total/Direct/Indirect Bilirubin
Tijdsspanne: Baseline
Serum Bilirubin Level (Total, Direct, Indirect) assessed by Liver Function Test (LFT)
Baseline
SGOT/AST (<37 U/L)
Tijdsspanne: Baseline
SGOT/AST Level assessed by Liver Function Test (LFT
Baseline
ALP (30-90 U/L)
Tijdsspanne: Baseline
Alkaline Phosphatase (ALP) Level assessed by Liver Function Test (LFT)
Baseline
Total Protein, Albumin, Globulin, A/G ratio
Tijdsspanne: Baseline
Serum Protein Level (Total Protein, Albumin, Globulin, A/G Ratio) assessed by Liver Function Test (LFT)
Baseline
Serum urea (13-43 mg/dl)
Tijdsspanne: Baseline
Serum Urea Level assessed by Renal Function Test (RFT)
Baseline
Uric acid (3.5-7.2 mg/dl)
Tijdsspanne: Baseline
Serum Uric Acid Level assessed by Renal Function Test (RFT)
Baseline
Calcium, Phosphorus
Tijdsspanne: Baseline
Serum Calcium and Phosphorus Level assessed by Renal Function Test (RFT)
Baseline
Sodium, Potassium, Chloride
Tijdsspanne: Baseline
Serum Electrolytes (Sodium, Potassium, Chloride) assessed by Renal Function Test (RFT)
Baseline

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Sponsor

Onderzoekers

  • Hoofdonderzoeker: Nayanabai Shabadi, M.D, JSS Medical College, Mysore

Publicaties en nuttige links

De persoon die verantwoordelijk is voor het invoeren van informatie over het onderzoek stelt deze publicaties vrijwillig ter beschikking. Dit kan gaan over alles wat met het onderzoek te maken heeft.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

3 oktober 2022

Primaire voltooiing (Werkelijk)

3 oktober 2023

Studie voltooiing (Werkelijk)

5 oktober 2023

Studieregistratiedata

Eerst ingediend

1 juni 2026

Eerst ingediend dat voldeed aan de QC-criteria

9 juni 2026

Eerst geplaatst (Werkelijk)

12 juni 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

12 juni 2026

Laatste update ingediend die voldeed aan QC-criteria

9 juni 2026

Laatst geverifieerd

1 juni 2026

Meer informatie

Termen gerelateerd aan deze studie

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Beschrijving IPD-plan

Individual participant data contains proprietary device output from a commercially sensitive medical technology. Data sharing is restricted due to intellectual property considerations and patient confidentiality

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren