- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT07668297
Correlation of Neck Dimensions of Airway Evaluation
Correlation of Thyromental Distance And Mandibular Triangle Perpendicular Length With Incisor Vallecular Distance In Adult Pre-Surgical Patients: An Observational Study
Studie Overzicht
Toestand
Gedetailleerde beschrijving
Preoperative evaluation of the upper airway is vital to the success, safety, and quality of airway access. The evaluation primarily aims to anticipate the course of direct laryngoscopy and intubation (DLI) of the trachea. While assessment of mouth opening, neck extension, and dentition forms the preliminary step of knowing whether DLI is feasible; there are certain other parameters whose evaluation facilitates understanding as to how the actual DLI will turn out. Among the secondary parameters, the linear thyromental distance (TMD) is an important measure that determines how the direct laryngoscopy aspect of conducting DLI will go - in terms of ease-of-laryngoscopy to gain the desired visual access to the view to the vocal cords. The ease of laryngoscopy involves as to how the laryngoscope blade would be able to displace tongue to one side, create forward space enhancement, and reach the vallecula at the base of the tongue; before lifting the epiglottis to view the cords. Though in use for over 4 decades, the TMD suffers from weakness, including, low sensitivity and specificity, not relating to the actual and direct teeth vallecular distance, and getting confounded by neck dimensions (thickness, length), state of dentition, and the tongue size.
The present study is built on the premise that it's the mandibular space to which the tongue is displaced at the time of DLI, the bony mandibular space is more exclusive of the confounders, and that the teeth (lower incisors) vallecular distance represent the actual distance that needs to be predicted.
The present study aims to evaluate TMD and mandibular triangle perpendicular length (MTPL); to know which correlates better with the incisor vallecula distance (IVD). Based on the direction and strength of the correlation measure, a multiple regression equation can then be created to first predict the IVD with external linear measure, and second, based on IVD length prediction, the appropriate laryngoscope blade size can be ascertained.
Studietype
Inschrijving (Geschat)
Contacten en locaties
Studiecontact
- Naam: Amitabh Dutta, MD
- Telefoonnummer: 00919810848064
- E-mail: duttaamitabh@yahoo.co.in
Studie Locaties
-
-
National Capital Territory of Delhi
-
New Delhi, National Capital Territory of Delhi, Indië, 110060
- Werving
- Sir Ganga Ram Hospital
-
Contact:
- Amitabh Dutta, MBBS, MD, PGDHR
- Telefoonnummer: 9810848064
- E-mail: duttaamitabh@yahoo.co.in
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Volwassen
- Oudere volwassene
Accepteert gezonde vrijwilligers
Bemonsteringsmethode
Studie Bevolking
Beschrijving
Inclusion Criteria:
- Age 18-65 years
- Males and females
- ASA (American Society of Anaesthesiologists) physical status I and II
- Patients scheduled for elective surgery with controlled ventilation through orotracheal tube conduit
Exclusion Criteria:
- Smokers (those who have smoked ≥100 cigarettes in their lifetime), chewing tobacco dependence or substance abuse
- Submucous fibrosis: progressive fibrosis of the submucosal tissue leading to rigidity, relative trismus, and progressive decrease of mouth opening
- Anticipated difficult airway
- Patients requiring intubation with MacIntosh blade #4 or #5
Dental issues:
- missing tooth (upper/lower incisors, upper/lower premolar)
- crowded dentition: - irregular, misaligned, or overlapping teeth within a relatively small oral cavity
presence of artificial teeth and/or dental implants
• Mandible/mandibular structure related issues:
- Retrognathia: - posterior displacement of the mandible relative to the maxilla or cranial base
- Prognathia: - anterior displacement of the mandible relative to the maxilla or cranial base
- Emergency Surgery
- Those requiring urgent rapid-sequence intubation due to the presence of a full-stomach status secondary to gastro-esophageal reflux disease, diaphragmatic hernia, among others.
- Refusal to informed consent
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Correlation of thyromental distance (TMD) and mandibular triangle perpendicular length (MTPL) with incisor vallecular distance (IVD)
Tijdsspanne: From entry into preoperative area (0 minutes) to time patient is shifted to operating room ( 10-minutes)
|
In all patients thyromental distance (TMD) and mandibular triangle perpendicular length (MTPL) will be measured.
TMD will be measured as a straight line distance between the bony mentum (tip of the chin) and the superior thyroid notch (upper border of the thyroid cartilage).
MTPL will be measured as the perpendicular of the mandibular triangle formed by joining the mental protuberence and point at angle of mandible on either side.
During direct larygngosocpoy when the tip of the laryngoscope blade lies on the vallecula, the distance between the laryngoscope blade tip and the point of laryngoscope blade flange overlying the lower incisors will be measured.
A correlation between TMD and MTPL with IVD if any will be established.
|
From entry into preoperative area (0 minutes) to time patient is shifted to operating room ( 10-minutes)
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Correlation of incisor vallecular distance (IVD), mandibular triangle perpendicular length (MTPL), and thyromental distance (TMD) with Macintosh blade (MCB) size#3 length
Tijdsspanne: From induction of anaesthesia (0 minutes) to insertion of endotracheal tube ( 10-minutes)
|
Macintosh blade size # 3 length will be determined by measuring the linear distance between the tip of the blade and the point where the concave surface of the blade flange joins the heel of the the laryngoscope blade.
A correlation between IVD, MTPL, and TMD with Macintosh blade size # 3 length if any will be established
|
From induction of anaesthesia (0 minutes) to insertion of endotracheal tube ( 10-minutes)
|
|
Cormack and Lehane score
Tijdsspanne: From induction of anaesthesia (0 minutes) to insertion of endotracheal tube ( 10-minutes)
|
The grade view to the glottic-opening upon direct laryngoscopy will be done using the 4-point Cormack-Lehane grading system (grade 1: entire glottic opening is seen; grade 2: anterior larynx not visualised, only posterior laryngeal aperture is seen; grade 3: only tip of epiglottis is seen; grade 4: neither glottis or epiglottis is visible, only soft palate is seen)
|
From induction of anaesthesia (0 minutes) to insertion of endotracheal tube ( 10-minutes)
|
Medewerkers en onderzoekers
Sponsor
Onderzoekers
- Hoofdonderzoeker: Amitabh Dutta, MD, Sir Ganga Ram Hospital, New Delhi-110060, India
- Hoofdonderzoeker: Paridhi Saboo, MBBS, Sir Ganga Ram Hospital, New Delhi-110060, India
- Studie directeur: Nitin Sethi, DNB, Sir Ganga Ram Hospital, New Delhi-110060, India
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Geschat)
Studie voltooiing (Geschat)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Andere studie-ID-nummers
- EC/06/26/2981
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .