- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT07668297
Correlation of Neck Dimensions of Airway Evaluation
Correlation of Thyromental Distance And Mandibular Triangle Perpendicular Length With Incisor Vallecular Distance In Adult Pre-Surgical Patients: An Observational Study
Visão geral do estudo
Status
Condições
Descrição detalhada
Preoperative evaluation of the upper airway is vital to the success, safety, and quality of airway access. The evaluation primarily aims to anticipate the course of direct laryngoscopy and intubation (DLI) of the trachea. While assessment of mouth opening, neck extension, and dentition forms the preliminary step of knowing whether DLI is feasible; there are certain other parameters whose evaluation facilitates understanding as to how the actual DLI will turn out. Among the secondary parameters, the linear thyromental distance (TMD) is an important measure that determines how the direct laryngoscopy aspect of conducting DLI will go - in terms of ease-of-laryngoscopy to gain the desired visual access to the view to the vocal cords. The ease of laryngoscopy involves as to how the laryngoscope blade would be able to displace tongue to one side, create forward space enhancement, and reach the vallecula at the base of the tongue; before lifting the epiglottis to view the cords. Though in use for over 4 decades, the TMD suffers from weakness, including, low sensitivity and specificity, not relating to the actual and direct teeth vallecular distance, and getting confounded by neck dimensions (thickness, length), state of dentition, and the tongue size.
The present study is built on the premise that it's the mandibular space to which the tongue is displaced at the time of DLI, the bony mandibular space is more exclusive of the confounders, and that the teeth (lower incisors) vallecular distance represent the actual distance that needs to be predicted.
The present study aims to evaluate TMD and mandibular triangle perpendicular length (MTPL); to know which correlates better with the incisor vallecula distance (IVD). Based on the direction and strength of the correlation measure, a multiple regression equation can then be created to first predict the IVD with external linear measure, and second, based on IVD length prediction, the appropriate laryngoscope blade size can be ascertained.
Tipo de estudo
Inscrição (Estimado)
Contactos e Locais
Contato de estudo
- Nome: Amitabh Dutta, MD
- Número de telefone: 00919810848064
- E-mail: duttaamitabh@yahoo.co.in
Locais de estudo
-
-
National Capital Territory of Delhi
-
New Delhi, National Capital Territory of Delhi, Índia, 110060
- Recrutamento
- Sir Ganga Ram Hospital
-
Contato:
- Amitabh Dutta, MBBS, MD, PGDHR
- Número de telefone: 9810848064
- E-mail: duttaamitabh@yahoo.co.in
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
- Adulto
- Adulto mais velho
Aceita Voluntários Saudáveis
Método de amostragem
População do estudo
Descrição
Inclusion Criteria:
- Age 18-65 years
- Males and females
- ASA (American Society of Anaesthesiologists) physical status I and II
- Patients scheduled for elective surgery with controlled ventilation through orotracheal tube conduit
Exclusion Criteria:
- Smokers (those who have smoked ≥100 cigarettes in their lifetime), chewing tobacco dependence or substance abuse
- Submucous fibrosis: progressive fibrosis of the submucosal tissue leading to rigidity, relative trismus, and progressive decrease of mouth opening
- Anticipated difficult airway
- Patients requiring intubation with MacIntosh blade #4 or #5
Dental issues:
- missing tooth (upper/lower incisors, upper/lower premolar)
- crowded dentition: - irregular, misaligned, or overlapping teeth within a relatively small oral cavity
presence of artificial teeth and/or dental implants
• Mandible/mandibular structure related issues:
- Retrognathia: - posterior displacement of the mandible relative to the maxilla or cranial base
- Prognathia: - anterior displacement of the mandible relative to the maxilla or cranial base
- Emergency Surgery
- Those requiring urgent rapid-sequence intubation due to the presence of a full-stomach status secondary to gastro-esophageal reflux disease, diaphragmatic hernia, among others.
- Refusal to informed consent
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Correlation of thyromental distance (TMD) and mandibular triangle perpendicular length (MTPL) with incisor vallecular distance (IVD)
Prazo: From entry into preoperative area (0 minutes) to time patient is shifted to operating room ( 10-minutes)
|
In all patients thyromental distance (TMD) and mandibular triangle perpendicular length (MTPL) will be measured.
TMD will be measured as a straight line distance between the bony mentum (tip of the chin) and the superior thyroid notch (upper border of the thyroid cartilage).
MTPL will be measured as the perpendicular of the mandibular triangle formed by joining the mental protuberence and point at angle of mandible on either side.
During direct larygngosocpoy when the tip of the laryngoscope blade lies on the vallecula, the distance between the laryngoscope blade tip and the point of laryngoscope blade flange overlying the lower incisors will be measured.
A correlation between TMD and MTPL with IVD if any will be established.
|
From entry into preoperative area (0 minutes) to time patient is shifted to operating room ( 10-minutes)
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Correlation of incisor vallecular distance (IVD), mandibular triangle perpendicular length (MTPL), and thyromental distance (TMD) with Macintosh blade (MCB) size#3 length
Prazo: From induction of anaesthesia (0 minutes) to insertion of endotracheal tube ( 10-minutes)
|
Macintosh blade size # 3 length will be determined by measuring the linear distance between the tip of the blade and the point where the concave surface of the blade flange joins the heel of the the laryngoscope blade.
A correlation between IVD, MTPL, and TMD with Macintosh blade size # 3 length if any will be established
|
From induction of anaesthesia (0 minutes) to insertion of endotracheal tube ( 10-minutes)
|
|
Cormack and Lehane score
Prazo: From induction of anaesthesia (0 minutes) to insertion of endotracheal tube ( 10-minutes)
|
The grade view to the glottic-opening upon direct laryngoscopy will be done using the 4-point Cormack-Lehane grading system (grade 1: entire glottic opening is seen; grade 2: anterior larynx not visualised, only posterior laryngeal aperture is seen; grade 3: only tip of epiglottis is seen; grade 4: neither glottis or epiglottis is visible, only soft palate is seen)
|
From induction of anaesthesia (0 minutes) to insertion of endotracheal tube ( 10-minutes)
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Amitabh Dutta, MD, Sir Ganga Ram Hospital, New Delhi-110060, India
- Investigador principal: Paridhi Saboo, MBBS, Sir Ganga Ram Hospital, New Delhi-110060, India
- Diretor de estudo: Nitin Sethi, DNB, Sir Ganga Ram Hospital, New Delhi-110060, India
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Estimado)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Outros números de identificação do estudo
- EC/06/26/2981
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .