Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

Horizontal vs Vertical Scleral Tunnels in Flanged IOL Fixation (HORVER)

7 juli 2026 bijgewerkt door: Sebahattin Celik MD, Yuzuncu Yil University

Horizontal Versus Vertical Scleral Tunnel Orientation in Flanged Intrascleral Fixation: A 2-Year Comparative Study

This study compares the 2-year outcomes of horizontal versus vertical scleral tunnel orientation in flanged intrascleral intraocular lens (IOL) fixation surgery. The primary outcome is the proportion of eyes achieving refraction within ±0.50 diopters of the target at 2 years. Secondary outcomes include IOL tilt measured by anterior segment optical coherence tomography (AS-OCT), iris capture, conjunctival erosion, and other complications. The study aims to determine whether tunnel orientation is associated with differing outcomes in this surgical technique.

Studie Overzicht

Gedetailleerde beschrijving

Background: The management of aphakia, crystalline lens luxation, and intraocular lens (IOL) luxation in the absence of adequate capsular support remains challenging. Traditional surgical options include anterior chamber IOLs, iris-fixated IOLs, and scleral-sutured posterior chamber IOLs, each carrying significant long-term risks. In 2017, Yamane and colleagues introduced a sutureless flanged intrascleral IOL fixation technique that rapidly gained worldwide acceptance. A critical yet under-investigated surgical variable is the orientation of the scleral tunnels relative to the limbus. Some surgeons create tunnels parallel to the limbus (horizontal/tangential), others perpendicular (vertical/radial), based on personal preference rather than high-level evidence.

Objective: To evaluate whether horizontal versus vertical scleral tunnel orientation is associated with differing 2-year outcomes in flanged intrascleral IOL fixation.

Study Design: This is a retrospective observational cohort study conducted at a single tertiary referral centre.

Participants: A total of 107 eyes (43 vertical tunnels, 64 horizontal tunnels) with complete 24-month follow-up are included. Surgeries are performed by two experienced vitreoretinal surgeons.

Interventions: All procedures follow the original Yamane flanged intrascleral fixation method with intentional variation in tunnel orientation only. The horizontal tunnel group receives tunnels parallel to the limbus (tangential), while the vertical tunnel group receives tunnels perpendicular to the limbus (radial). A three-piece foldable acrylic IOL (Alcon AcrySof MA60AC) is used in all eyes.

Outcome Measures: The primary outcome is the proportion of eyes achieving mean absolute error (MAE) within ±0.50D of target refraction at 2 years. Secondary outcomes include MAE at 2 years, IOL tilt measured using anterior segment optical coherence tomography (AS-OCT), iris capture, conjunctival erosion, cystoid macular oedema, epiretinal membrane, retinal detachment, vitreous haemorrhage, hypotony, corneal oedema, early IOP elevation, best-corrected visual acuity (BCVA), and vector astigmatism analysis using the Alpins method.

Statistical Analysis: Propensity score matching (1:1) will be performed to address selection bias. Multivariate logistic regression and a multilevel mixed-effects model with surgeon as random effect will be used to adjust for confounders including surgical period, age, and baseline refraction. For the primary outcome, a single pre-specified comparison will be made with a two-tailed significance level of α = 0.05. For secondary outcomes, the False Discovery Rate (FDR) using the Benjamini-Hochberg procedure (q = 0.05) will be applied to control for Type I error inflation.

Timeline: Data were collected from patients who underwent surgery between March 1, 2022, and March 1, 2025. Minimum follow-up is 24 months, with final data collection completed in March 2025.

Studietype

Observationeel

Inschrijving (Werkelijk)

107

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

      • Van, Turkije (Türkiye), 65000
        • SBU Van Training and Research Hospital

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Volwassen
  • Oudere volwassene

Accepteert gezonde vrijwilligers

Nee

Bemonsteringsmethode

Niet-waarschijnlijkheidssteekproef

Studie Bevolking

Patients with aphakia, crystalline lens luxation, or intraocular lens luxation in the absence of adequate capsular support who underwent flanged intrascleral IOL fixation surgery at a single tertiary referral centre between March 1, 2022, and March 1, 2025. All patients were aged 18 years or older and completed 24 months of follow-up.

Beschrijving

Inclusion Criteria:

  • Age ≥ 18 years
  • Complicated aphakia defined as absence of adequate capsular support following cataract extraction, lens trauma, or previous lensectomy
  • Crystalline lens luxation defined as partial or complete displacement of the natural lens due to zonular weakness
  • Intraocular lens (IOL) luxation defined as partial or complete dislocation of a previously implanted IOL
  • Inadequate capsular support (<180° of intact zonular or capsular support)
  • Ability to complete scheduled follow-up visits
  • Complete follow-up data available

Exclusion Criteria:

  • Previous scleral buckling surgery within 6 months
  • Pars plana vitrectomy within 3 months
  • Active uveitis
  • Active endophthalmitis
  • Uncontrolled scleritis or scleral thinning
  • Corneal decompensation (endothelial cell density <1000 cells/mm²)
  • Uncontrolled glaucoma (IOP >25 mmHg despite maximum therapy)
  • History of penetrating keratoplasty, DALK, DSEK, or DMEK
  • History of corneal refractive surgery
  • Active proliferative diabetic retinopathy
  • Pregnancy or breastfeeding
  • Inability to complete 24-month follow-up

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

Cohorten en interventies

Groep / Cohort
Interventie / Behandeling
Vertical Scleral Tunnel Group
Patients who underwent flanged intrascleral IOL fixation with scleral tunnels created perpendicular to the limbus (radial/vertical orientation).
Sutureless flanged intrascleral fixation of a three-piece foldable acrylic IOL (Alcon AcrySof MA60AC). Two partial-thickness scleral tunnels are created 2.0 mm posterior to the limbus, 180° apart. Haptics are externalized through the tunnels, and a flange is created on each haptic tip using thermal cautery. Tunnel orientation varied intentionally: horizontal (parallel to limbus) or vertical (perpendicular to limbus).
Horizontal Scleral Tunnel Group
Patients who underwent flanged intrascleral IOL fixation with scleral tunnels created parallel to the limbus (tangential/horizontal orientation).
Sutureless flanged intrascleral fixation of a three-piece foldable acrylic IOL (Alcon AcrySof MA60AC). Two partial-thickness scleral tunnels are created 2.0 mm posterior to the limbus, 180° apart. Haptics are externalized through the tunnels, and a flange is created on each haptic tip using thermal cautery. Tunnel orientation varied intentionally: horizontal (parallel to limbus) or vertical (perpendicular to limbus).

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Proportion of Eyes Achieving Mean Absolute Error (MAE) Within ±0.50 Diopters of Target Refraction
Tijdsspanne: 24 Months
The proportion of eyes achieving mean absolute error (MAE) within ±0.50 diopters of the target spherical equivalent refraction at 24 months postoperatively.
24 Months

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Mean Absolute Error (MAE) at 2 Years
Tijdsspanne: 24 Months
Mean absolute error in spherical equivalent refraction at 24 months postoperatively.
24 Months
IOL Tilt Angle
Tijdsspanne: 24 Months
Intraocular lens tilt angle measured using anterior segment optical coherence tomography (AS-OCT) at 24 months postoperatively.
24 Months

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Publicaties en nuttige links

De persoon die verantwoordelijk is voor het invoeren van informatie over het onderzoek stelt deze publicaties vrijwillig ter beschikking. Dit kan gaan over alles wat met het onderzoek te maken heeft.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

1 maart 2022

Primaire voltooiing (Werkelijk)

1 maart 2025

Studie voltooiing (Werkelijk)

1 maart 2025

Studieregistratiedata

Eerst ingediend

1 juli 2026

Eerst ingediend dat voldeed aan de QC-criteria

7 juli 2026

Eerst geplaatst (Werkelijk)

14 juli 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

14 juli 2026

Laatste update ingediend die voldeed aan QC-criteria

7 juli 2026

Laatst geverifieerd

1 juli 2026

Meer informatie

Termen gerelateerd aan deze studie

Andere studie-ID-nummers

  • GOKAEK-2024-04-02 (Andere identificatie: Van Training and Research Hospital Ethics Committee)

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Beschrijving IPD-plan

Individual participant data will not be shared due to institutional data protection policies and patient privacy regulations. Anonymized aggregate data may be available from the corresponding author upon reasonable request.

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren