Horizontal vs Vertical Scleral Tunnels in Flanged IOL Fixation (HORVER)
Horizontal Versus Vertical Scleral Tunnel Orientation in Flanged Intrascleral Fixation: A 2-Year Comparative Study
Přehled studie
Postavení
Intervence / Léčba
Detailní popis
Background: The management of aphakia, crystalline lens luxation, and intraocular lens (IOL) luxation in the absence of adequate capsular support remains challenging. Traditional surgical options include anterior chamber IOLs, iris-fixated IOLs, and scleral-sutured posterior chamber IOLs, each carrying significant long-term risks. In 2017, Yamane and colleagues introduced a sutureless flanged intrascleral IOL fixation technique that rapidly gained worldwide acceptance. A critical yet under-investigated surgical variable is the orientation of the scleral tunnels relative to the limbus. Some surgeons create tunnels parallel to the limbus (horizontal/tangential), others perpendicular (vertical/radial), based on personal preference rather than high-level evidence.
Objective: To evaluate whether horizontal versus vertical scleral tunnel orientation is associated with differing 2-year outcomes in flanged intrascleral IOL fixation.
Study Design: This is a retrospective observational cohort study conducted at a single tertiary referral centre.
Participants: A total of 107 eyes (43 vertical tunnels, 64 horizontal tunnels) with complete 24-month follow-up are included. Surgeries are performed by two experienced vitreoretinal surgeons.
Interventions: All procedures follow the original Yamane flanged intrascleral fixation method with intentional variation in tunnel orientation only. The horizontal tunnel group receives tunnels parallel to the limbus (tangential), while the vertical tunnel group receives tunnels perpendicular to the limbus (radial). A three-piece foldable acrylic IOL (Alcon AcrySof MA60AC) is used in all eyes.
Outcome Measures: The primary outcome is the proportion of eyes achieving mean absolute error (MAE) within ±0.50D of target refraction at 2 years. Secondary outcomes include MAE at 2 years, IOL tilt measured using anterior segment optical coherence tomography (AS-OCT), iris capture, conjunctival erosion, cystoid macular oedema, epiretinal membrane, retinal detachment, vitreous haemorrhage, hypotony, corneal oedema, early IOP elevation, best-corrected visual acuity (BCVA), and vector astigmatism analysis using the Alpins method.
Statistical Analysis: Propensity score matching (1:1) will be performed to address selection bias. Multivariate logistic regression and a multilevel mixed-effects model with surgeon as random effect will be used to adjust for confounders including surgical period, age, and baseline refraction. For the primary outcome, a single pre-specified comparison will be made with a two-tailed significance level of α = 0.05. For secondary outcomes, the False Discovery Rate (FDR) using the Benjamini-Hochberg procedure (q = 0.05) will be applied to control for Type I error inflation.
Timeline: Data were collected from patients who underwent surgery between March 1, 2022, and March 1, 2025. Minimum follow-up is 24 months, with final data collection completed in March 2025.
Typ studie
Zápis (Aktuální)
Kontakty a umístění
Studijní místa
-
-
-
Van, Turecko (Türkiye), 65000
- SBU Van Training and Research Hospital
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
- Dospělý
- Starší dospělý
Přijímá zdravé dobrovolníky
Metoda odběru vzorků
Studijní populace
Popis
Inclusion Criteria:
- Age ≥ 18 years
- Complicated aphakia defined as absence of adequate capsular support following cataract extraction, lens trauma, or previous lensectomy
- Crystalline lens luxation defined as partial or complete displacement of the natural lens due to zonular weakness
- Intraocular lens (IOL) luxation defined as partial or complete dislocation of a previously implanted IOL
- Inadequate capsular support (<180° of intact zonular or capsular support)
- Ability to complete scheduled follow-up visits
- Complete follow-up data available
Exclusion Criteria:
- Previous scleral buckling surgery within 6 months
- Pars plana vitrectomy within 3 months
- Active uveitis
- Active endophthalmitis
- Uncontrolled scleritis or scleral thinning
- Corneal decompensation (endothelial cell density <1000 cells/mm²)
- Uncontrolled glaucoma (IOP >25 mmHg despite maximum therapy)
- History of penetrating keratoplasty, DALK, DSEK, or DMEK
- History of corneal refractive surgery
- Active proliferative diabetic retinopathy
- Pregnancy or breastfeeding
- Inability to complete 24-month follow-up
Studijní plán
Jak je studie koncipována?
Detaily designu
Kohorty a intervence
Skupina / kohorta |
Intervence / Léčba |
|---|---|
|
Vertical Scleral Tunnel Group
Patients who underwent flanged intrascleral IOL fixation with scleral tunnels created perpendicular to the limbus (radial/vertical orientation).
|
Sutureless flanged intrascleral fixation of a three-piece foldable acrylic IOL (Alcon AcrySof MA60AC).
Two partial-thickness scleral tunnels are created 2.0 mm posterior to the limbus, 180° apart.
Haptics are externalized through the tunnels, and a flange is created on each haptic tip using thermal cautery.
Tunnel orientation varied intentionally: horizontal (parallel to limbus) or vertical (perpendicular to limbus).
|
|
Horizontal Scleral Tunnel Group
Patients who underwent flanged intrascleral IOL fixation with scleral tunnels created parallel to the limbus (tangential/horizontal orientation).
|
Sutureless flanged intrascleral fixation of a three-piece foldable acrylic IOL (Alcon AcrySof MA60AC).
Two partial-thickness scleral tunnels are created 2.0 mm posterior to the limbus, 180° apart.
Haptics are externalized through the tunnels, and a flange is created on each haptic tip using thermal cautery.
Tunnel orientation varied intentionally: horizontal (parallel to limbus) or vertical (perpendicular to limbus).
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Proportion of Eyes Achieving Mean Absolute Error (MAE) Within ±0.50 Diopters of Target Refraction
Časové okno: 24 Months
|
The proportion of eyes achieving mean absolute error (MAE) within ±0.50 diopters of the target spherical equivalent refraction at 24 months postoperatively.
|
24 Months
|
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Mean Absolute Error (MAE) at 2 Years
Časové okno: 24 Months
|
Mean absolute error in spherical equivalent refraction at 24 months postoperatively.
|
24 Months
|
|
IOL Tilt Angle
Časové okno: 24 Months
|
Intraocular lens tilt angle measured using anterior segment optical coherence tomography (AS-OCT) at 24 months postoperatively.
|
24 Months
|
Spolupracovníci a vyšetřovatelé
Sponzor
Publikace a užitečné odkazy
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Primární dokončení (Aktuální)
Dokončení studie (Aktuální)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další identifikační čísla studie
- GOKAEK-2024-04-02 (Jiný identifikátor: Van Training and Research Hospital Ethics Committee)
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Popis plánu IPD
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .
Klinické studie na Dislokace nitrooční čočky
-
University of Texas Southwestern Medical CenterDokončenoVýsledky po obnovení implantátu IOL LensSpojené státy
-
Contamac LtdAndre Vision and Device Research; The Contact Lens Center at Optique; Premiere... a další spolupracovníciDokončenoKomplikace kontaktních čoček | Nečistoty v nádrži na roztržení post LensSpojené státy
-
Medical University of ViennaNáborLuxace objektivu | Subluxace IOL | Opacifikaci IOL | Aphakia - No Lens CapsuleRakousko