Esta página se tradujo automáticamente y no se garantiza la precisión de la traducción. por favor refiérase a versión inglesa para un texto fuente.

Horizontal vs Vertical Scleral Tunnels in Flanged IOL Fixation (HORVER)

7 de julio de 2026 actualizado por: Sebahattin Celik MD, Yuzuncu Yil University

Horizontal Versus Vertical Scleral Tunnel Orientation in Flanged Intrascleral Fixation: A 2-Year Comparative Study

This study compares the 2-year outcomes of horizontal versus vertical scleral tunnel orientation in flanged intrascleral intraocular lens (IOL) fixation surgery. The primary outcome is the proportion of eyes achieving refraction within ±0.50 diopters of the target at 2 years. Secondary outcomes include IOL tilt measured by anterior segment optical coherence tomography (AS-OCT), iris capture, conjunctival erosion, and other complications. The study aims to determine whether tunnel orientation is associated with differing outcomes in this surgical technique.

Descripción general del estudio

Descripción detallada

Background: The management of aphakia, crystalline lens luxation, and intraocular lens (IOL) luxation in the absence of adequate capsular support remains challenging. Traditional surgical options include anterior chamber IOLs, iris-fixated IOLs, and scleral-sutured posterior chamber IOLs, each carrying significant long-term risks. In 2017, Yamane and colleagues introduced a sutureless flanged intrascleral IOL fixation technique that rapidly gained worldwide acceptance. A critical yet under-investigated surgical variable is the orientation of the scleral tunnels relative to the limbus. Some surgeons create tunnels parallel to the limbus (horizontal/tangential), others perpendicular (vertical/radial), based on personal preference rather than high-level evidence.

Objective: To evaluate whether horizontal versus vertical scleral tunnel orientation is associated with differing 2-year outcomes in flanged intrascleral IOL fixation.

Study Design: This is a retrospective observational cohort study conducted at a single tertiary referral centre.

Participants: A total of 107 eyes (43 vertical tunnels, 64 horizontal tunnels) with complete 24-month follow-up are included. Surgeries are performed by two experienced vitreoretinal surgeons.

Interventions: All procedures follow the original Yamane flanged intrascleral fixation method with intentional variation in tunnel orientation only. The horizontal tunnel group receives tunnels parallel to the limbus (tangential), while the vertical tunnel group receives tunnels perpendicular to the limbus (radial). A three-piece foldable acrylic IOL (Alcon AcrySof MA60AC) is used in all eyes.

Outcome Measures: The primary outcome is the proportion of eyes achieving mean absolute error (MAE) within ±0.50D of target refraction at 2 years. Secondary outcomes include MAE at 2 years, IOL tilt measured using anterior segment optical coherence tomography (AS-OCT), iris capture, conjunctival erosion, cystoid macular oedema, epiretinal membrane, retinal detachment, vitreous haemorrhage, hypotony, corneal oedema, early IOP elevation, best-corrected visual acuity (BCVA), and vector astigmatism analysis using the Alpins method.

Statistical Analysis: Propensity score matching (1:1) will be performed to address selection bias. Multivariate logistic regression and a multilevel mixed-effects model with surgeon as random effect will be used to adjust for confounders including surgical period, age, and baseline refraction. For the primary outcome, a single pre-specified comparison will be made with a two-tailed significance level of α = 0.05. For secondary outcomes, the False Discovery Rate (FDR) using the Benjamini-Hochberg procedure (q = 0.05) will be applied to control for Type I error inflation.

Timeline: Data were collected from patients who underwent surgery between March 1, 2022, and March 1, 2025. Minimum follow-up is 24 months, with final data collection completed in March 2025.

Tipo de estudio

De observación

Inscripción (Actual)

107

Contactos y Ubicaciones

Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.

Ubicaciones de estudio

Criterios de participación

Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.

Criterio de elegibilidad

Edades elegibles para estudiar

  • Adulto
  • Adulto Mayor

Acepta Voluntarios Saludables

No

Método de muestreo

Muestra no probabilística

Población de estudio

Patients with aphakia, crystalline lens luxation, or intraocular lens luxation in the absence of adequate capsular support who underwent flanged intrascleral IOL fixation surgery at a single tertiary referral centre between March 1, 2022, and March 1, 2025. All patients were aged 18 years or older and completed 24 months of follow-up.

Descripción

Inclusion Criteria:

  • Age ≥ 18 years
  • Complicated aphakia defined as absence of adequate capsular support following cataract extraction, lens trauma, or previous lensectomy
  • Crystalline lens luxation defined as partial or complete displacement of the natural lens due to zonular weakness
  • Intraocular lens (IOL) luxation defined as partial or complete dislocation of a previously implanted IOL
  • Inadequate capsular support (<180° of intact zonular or capsular support)
  • Ability to complete scheduled follow-up visits
  • Complete follow-up data available

Exclusion Criteria:

  • Previous scleral buckling surgery within 6 months
  • Pars plana vitrectomy within 3 months
  • Active uveitis
  • Active endophthalmitis
  • Uncontrolled scleritis or scleral thinning
  • Corneal decompensation (endothelial cell density <1000 cells/mm²)
  • Uncontrolled glaucoma (IOP >25 mmHg despite maximum therapy)
  • History of penetrating keratoplasty, DALK, DSEK, or DMEK
  • History of corneal refractive surgery
  • Active proliferative diabetic retinopathy
  • Pregnancy or breastfeeding
  • Inability to complete 24-month follow-up

Plan de estudios

Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.

¿Cómo está diseñado el estudio?

Detalles de diseño

Cohortes e Intervenciones

Grupo / Cohorte
Intervención / Tratamiento
Vertical Scleral Tunnel Group
Patients who underwent flanged intrascleral IOL fixation with scleral tunnels created perpendicular to the limbus (radial/vertical orientation).
Sutureless flanged intrascleral fixation of a three-piece foldable acrylic IOL (Alcon AcrySof MA60AC). Two partial-thickness scleral tunnels are created 2.0 mm posterior to the limbus, 180° apart. Haptics are externalized through the tunnels, and a flange is created on each haptic tip using thermal cautery. Tunnel orientation varied intentionally: horizontal (parallel to limbus) or vertical (perpendicular to limbus).
Horizontal Scleral Tunnel Group
Patients who underwent flanged intrascleral IOL fixation with scleral tunnels created parallel to the limbus (tangential/horizontal orientation).
Sutureless flanged intrascleral fixation of a three-piece foldable acrylic IOL (Alcon AcrySof MA60AC). Two partial-thickness scleral tunnels are created 2.0 mm posterior to the limbus, 180° apart. Haptics are externalized through the tunnels, and a flange is created on each haptic tip using thermal cautery. Tunnel orientation varied intentionally: horizontal (parallel to limbus) or vertical (perpendicular to limbus).

¿Qué mide el estudio?

Medidas de resultado primarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Proportion of Eyes Achieving Mean Absolute Error (MAE) Within ±0.50 Diopters of Target Refraction
Periodo de tiempo: 24 Months
The proportion of eyes achieving mean absolute error (MAE) within ±0.50 diopters of the target spherical equivalent refraction at 24 months postoperatively.
24 Months

Medidas de resultado secundarias

Medida de resultado
Medida Descripción
Periodo de tiempo
Mean Absolute Error (MAE) at 2 Years
Periodo de tiempo: 24 Months
Mean absolute error in spherical equivalent refraction at 24 months postoperatively.
24 Months
IOL Tilt Angle
Periodo de tiempo: 24 Months
Intraocular lens tilt angle measured using anterior segment optical coherence tomography (AS-OCT) at 24 months postoperatively.
24 Months

Colaboradores e Investigadores

Aquí es donde encontrará personas y organizaciones involucradas en este estudio.

Patrocinador

Publicaciones y enlaces útiles

La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.

Fechas de registro del estudio

Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados ​​por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.

Fechas importantes del estudio

Inicio del estudio (Actual)

1 de marzo de 2022

Finalización primaria (Actual)

1 de marzo de 2025

Finalización del estudio (Actual)

1 de marzo de 2025

Fechas de registro del estudio

Enviado por primera vez

1 de julio de 2026

Primero enviado que cumplió con los criterios de control de calidad

7 de julio de 2026

Publicado por primera vez (Actual)

14 de julio de 2026

Actualizaciones de registros de estudio

Última actualización publicada (Actual)

14 de julio de 2026

Última actualización enviada que cumplió con los criterios de control de calidad

7 de julio de 2026

Última verificación

1 de julio de 2026

Más información

Términos relacionados con este estudio

Otros números de identificación del estudio

  • GOKAEK-2024-04-02 (Otro identificador: Van Training and Research Hospital Ethics Committee)

Plan de datos de participantes individuales (IPD)

¿Planea compartir datos de participantes individuales (IPD)?

NO

Descripción del plan IPD

Individual participant data will not be shared due to institutional data protection policies and patient privacy regulations. Anonymized aggregate data may be available from the corresponding author upon reasonable request.

Información sobre medicamentos y dispositivos, documentos del estudio

Estudia un producto farmacéutico regulado por la FDA de EE. UU.

No

Estudia un producto de dispositivo regulado por la FDA de EE. UU.

No

Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .

Suscribir