- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT07897318
Mi2000 TICI - Post-market Implantation Study (TUPIS)
This Post-Market Clinical Follow-up (PMCF) investigation aims to further collect evidence on safety and performance of the Mi2000 TICI. This PMCF investigation will prospectively collect clinical data from the use of the Mi2000 TICI and related devices.
This PMCF investigation is performed on a cochlear implant system newly introduced to the market, which was previously studied in two pre-market clinical investigations. The purpose of the current clinical investigation is to collect further evidence by collecting additional clinical data on the use of the Mi2000 TICI.
Studie Overzicht
Toestand
Interventie / Behandeling
Studietype
Inschrijving (Geschat)
Fase
- Niet toepasbaar
Contacten en locaties
Studiecontact
- Naam: Florian Schwarze, PhD
- Telefoonnummer: +4357788
- E-mail: studies@medel.com
Studie Locaties
-
-
-
Liège, België, 4000
- Nog niet aan het werven
- Centre Hospitalier Universitaire de Liège, Department ORL
-
Contact:
- Philippe Lefebvre, Dr.med.
-
-
Belgium
-
Antwerp, Belgium, België, 2650
- Nog niet aan het werven
- UZA Antwerpen
-
Contact:
- Vincent van Rompaey, Prof. Dr.
-
-
-
-
-
Würzburg, Duitsland
- Nog niet aan het werven
- Universitätsklinikum Würzburg
-
Contact:
- Kristen Rak, Prof. Dr.
-
-
Bavaria
-
München, Bavaria, Duitsland, 81377
- Werving
- Klinikum der Universität München, Campus Großhadern
-
Contact:
- Joachim Müller, Dr.med.
-
-
-
-
State of Vienna
-
Vienna, State of Vienna, Oostenrijk, 1090
- Nog niet aan het werven
- AKH Wien
-
Contact:
- Christoph Arnoldner, Prof. Dr.
- E-mail: christoph.arnoldner@meduniwien.ac.at
-
-
-
-
Poland
-
Nadarzyn, Poland, Polen, 05-830
- Nog niet aan het werven
- The Institute of Physiology and Pathology of Hearing
-
Contact:
- Piotr Skarzynski, Prof. Dr.
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Minimum age of eighteen (18) years at time of enrolment
- Bilateral sensorineural hearing loss with no or limited benefit from a hearing aid (>70 dB HL PTA4(500, 1000, 2000, 4000Hz))
- Post-lingual onset of deafness
- No or limited benefit from hearing aids for less than 10 years and an expected benefit from cochlear implantation
- A maximum score of 50% on a word test in the language of the test center in the ear to be implanted in the best aided condition
- Fluency in the test language with excellent proficiency, as appropriate to perform speech testing
- Functional auditory nerve
- General health condition, psychological and emotional condition deemed compatible with the treatment and tests performed in this study
- Pre-operative assessment according to the local professional standards
- Candidate is highly motivated and has realistic expectations about the expected benefit of the implant and shall understand the importance of returning to the implant center for regular speech processor programming, assessment sessions and training
- Realistic expectations, as deemed appropriate by the implanting surgeon/implant board
- Signed and dated informed consent before the start of any study-specific procedure
Exclusion Criteria:
-
Lack of compliance with any inclusion criterion
-
Previously having received an implant on the location chosen for placing the cochlear implant
-
Having received a hearing implant from another manufacturer than MED-EL on the contralateral ear
-
Pre-existing condition known to necessitate MRI scans after implantation of the Mi2000 TICI
-
Women being pregnant or nursing
-
The individual is known to be intolerant of the materials used in the implant or other required accessories
-
Absence of cochlear development
-
The cause of deafness is non-functionality of the auditory nerve and/or the upper auditory pathway
-
Medical contra-indications to middle ear and/or inner ear surgery, and/or anesthesia
-
External or middle ear infections are present
-
The tympanic membrane is perforated in the ear to be implanted
-
Anatomic abnormalities are present that would prevent appropriate placement of the stimulator housing in the bone of the skull, or prevent placement of the chosen electrode array into the cochlea (including ossification of the cochlea)
-
The psychological status of the individual is unstable
-
The individual has unrealistic expectations
-
Acute cholesteatoma
-
History of vestibular schwannoma
-
Unstable Meniere's disease
-
Auditory Neuropathy
-
Epilepsy not responding to treatment
-
Permanent inability and/or unwillingness to participation in post-operative care and rehabilitation
-
Known intellectual disability and/or psychological diseases
-
Participation in other pharmacological clinical trials within four weeks prior to enrolment
-
Anything that, in the opinion of the Investigator, would
- place the subject at increased risk
- preclude the subject's full compliance with or completion of the study
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Behandeling
- Toewijzing: NVT
- Interventioneel model: Opdracht voor een enkele groep
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: TICI recipients
Participants in this clinical investigation will be implanted with an Mi2000 TICI totally cochlear implant |
Participants in this clinical investigation will receive a totally implantable cochlear implant. |
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Word Test in Quiet
Tijdsspanne: Pre-op to 6 months after first fitting
|
Word recognition in quiet, on a scale from 0 to 100% correct, higher scores indicate better outcomes |
Pre-op to 6 months after first fitting
|
|
Sentence Test in Noise
Tijdsspanne: Pre-op to 6 months after first fitting
|
Oldenburg Matrix Test, results measured in dB signal-to-noise ratio (SNR) with a range of +30 to -10 dB SNR, lower values indicating better outcomes |
Pre-op to 6 months after first fitting
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Health Utility Index Mark 3 (HUI3)
Tijdsspanne: Pre-op to 6 months after first fitting
|
Health utility scale: 1.00: Perfect health. 0.00: Death. Negative values: States worse than death. |
Pre-op to 6 months after first fitting
|
|
Nijmegen Cochlear Implant Questionnaire (NCIQ)
Tijdsspanne: Pre-op to 6 months after first fitting
|
Disease specific Quality of Life, overall score is on a scale from 0 to 100, higher numbers indicating better outcomes |
Pre-op to 6 months after first fitting
|
|
Change in body sound perception
Tijdsspanne: through study completion, an average of 12 months after first fitting
|
Participant reported scale on body sound perception (0 - no disturbance to 10 - very disturbing) |
through study completion, an average of 12 months after first fitting
|
|
Change in stigma perception
Tijdsspanne: through study completion, an average of 12 months after first fitting
|
Participant reported scale on stigma perception (0 - no stigmatization to 10 - strong stigmatization) |
through study completion, an average of 12 months after first fitting
|
|
Change in comfort perception
Tijdsspanne: through study completion, an average of 12 months after first fitting
|
Participant reported scale on stigma perception (0 - not comfortable to 10 - very comfortable) |
through study completion, an average of 12 months after first fitting
|
Andere uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Word test in quiet
Tijdsspanne: through study completion, an average of 12 months after first fitting
|
Word recognition in quiet, on a scale from 0 to 100% correct, higher scores indicate better outcomes |
through study completion, an average of 12 months after first fitting
|
|
Sentence Test in Noise
Tijdsspanne: through study completion, an average of 12 months after first fitting
|
Oldenburg Matrix Test, results measured in dB signal-to-noise ratio (SNR) with a range of +30 to -10 dB SNR, lower values indicating better outcomes |
through study completion, an average of 12 months after first fitting
|
|
Health Utility Index Mark 3 (HUI3)
Tijdsspanne: through study completion, an average of 12 months after first fitting
|
Health utility scale: 1.00: Perfect health. 0.00: Death. Negative values: States worse than death. |
through study completion, an average of 12 months after first fitting
|
|
Nijmegen Cochlear Implant Questionnaire (NCIQ)
Tijdsspanne: through study completion, an average of 12 months after first fitting
|
Disease specific Quality of Life, overall score is on a scale from 0 to 100, higher numbers indicating better outcomes |
through study completion, an average of 12 months after first fitting
|
|
Speech, Spatial, Quality of Hearing (SSQ12)
Tijdsspanne: through study completion, an average of 12 months after first fitting
|
Speech, Spatial and Quality of hearing scale from 0 to 10, higher numbers indicating better outcomes |
through study completion, an average of 12 months after first fitting
|
|
Hearing Implant Sound Quality Index (HISQUI)
Tijdsspanne: through study completion, an average of 12 months after first fitting
|
Sound quality score ranging from 19 (very poor sound quality) to 133 (very good sound quality) |
through study completion, an average of 12 months after first fitting
|
|
Tinnitus Functional Index (TFI)
Tijdsspanne: through study completion, an average of 12 months after first fitting
|
Tinnitus questionnaire measures the severity and negative impact of tinnitus on a 0 (Not a Problem / Slight Tinnitus) to 100 (Very Big Problem / Very Severe Tinnitus) scale |
through study completion, an average of 12 months after first fitting
|
|
Audiogram
Tijdsspanne: through study completion, an average of 12 months after first fitting
|
Pure-tone air-conduction hearing thresholds will be measured in each ear. The threshold is the lowest sound level, in decibels hearing level (dB HL), at which the participant responds. The outcome is the threshold at each frequency. Higher thresholds mean poorer hearing; lower thresholds better hearing. |
through study completion, an average of 12 months after first fitting
|
Medewerkers en onderzoekers
Onderzoekers
- Studie directeur: Florian Schwarze, MED-EL
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Geschat)
Studie voltooiing (Geschat)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
- Neurologische manifestaties
- Ziekten van het zenuwstelsel
- KNO-ziekten
- Sensatiestoornissen
- Oor Ziekten
- Gehoorstoornissen
- Pathologische aandoeningen, tekenen en symptomen
- Tekenen en symptomen
- Gehoorverlies
- Chirurgische procedures, operatief
- Prothese Implantatie
- Otorhinolaryngologische chirurgische procedures
- Otologische chirurgische procedures
- Cochleaire implantatie
Andere studie-ID-nummers
- MED-EL_CRD_2026_03
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
product vervaardigd in en geëxporteerd uit de V.S.
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .