- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT07897318
Mi2000 TICI - Post-market Implantation Study (TUPIS)
This Post-Market Clinical Follow-up (PMCF) investigation aims to further collect evidence on safety and performance of the Mi2000 TICI. This PMCF investigation will prospectively collect clinical data from the use of the Mi2000 TICI and related devices.
This PMCF investigation is performed on a cochlear implant system newly introduced to the market, which was previously studied in two pre-market clinical investigations. The purpose of the current clinical investigation is to collect further evidence by collecting additional clinical data on the use of the Mi2000 TICI.
Przegląd badań
Status
Interwencja / Leczenie
Typ studiów
Zapisy (Szacowany)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Kontakt w sprawie studiów
- Nazwa: Florian Schwarze, PhD
- Numer telefonu: +4357788
- E-mail: studies@medel.com
Lokalizacje studiów
-
-
State of Vienna
-
Vienna, State of Vienna, Austria, 1090
- Jeszcze nie rekrutacja
- AKH Wien
-
Kontakt:
- Christoph Arnoldner, Prof. Dr.
- E-mail: christoph.arnoldner@meduniwien.ac.at
-
-
-
-
-
Liège, Belgia, 4000
- Jeszcze nie rekrutacja
- Centre Hospitalier Universitaire de Liège, Department ORL
-
Kontakt:
- Philippe Lefebvre, Dr.med.
-
-
Belgium
-
Antwerp, Belgium, Belgia, 2650
- Jeszcze nie rekrutacja
- UZA Antwerpen
-
Kontakt:
- Vincent van Rompaey, Prof. Dr.
-
-
-
-
-
Würzburg, Niemcy
- Jeszcze nie rekrutacja
- Universitätsklinikum Würzburg
-
Kontakt:
- Kristen Rak, Prof. Dr.
-
-
Bavaria
-
München, Bavaria, Niemcy, 81377
- Rekrutacyjny
- Klinikum der Universität München, Campus Großhadern
-
Kontakt:
- Joachim Müller, Dr.med.
-
-
-
-
Poland
-
Nadarzyn, Poland, Polska, 05-830
- Jeszcze nie rekrutacja
- The Institute of Physiology and Pathology of Hearing
-
Kontakt:
- Piotr Skarzynski, Prof. Dr.
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- Minimum age of eighteen (18) years at time of enrolment
- Bilateral sensorineural hearing loss with no or limited benefit from a hearing aid (>70 dB HL PTA4(500, 1000, 2000, 4000Hz))
- Post-lingual onset of deafness
- No or limited benefit from hearing aids for less than 10 years and an expected benefit from cochlear implantation
- A maximum score of 50% on a word test in the language of the test center in the ear to be implanted in the best aided condition
- Fluency in the test language with excellent proficiency, as appropriate to perform speech testing
- Functional auditory nerve
- General health condition, psychological and emotional condition deemed compatible with the treatment and tests performed in this study
- Pre-operative assessment according to the local professional standards
- Candidate is highly motivated and has realistic expectations about the expected benefit of the implant and shall understand the importance of returning to the implant center for regular speech processor programming, assessment sessions and training
- Realistic expectations, as deemed appropriate by the implanting surgeon/implant board
- Signed and dated informed consent before the start of any study-specific procedure
Exclusion Criteria:
-
Lack of compliance with any inclusion criterion
-
Previously having received an implant on the location chosen for placing the cochlear implant
-
Having received a hearing implant from another manufacturer than MED-EL on the contralateral ear
-
Pre-existing condition known to necessitate MRI scans after implantation of the Mi2000 TICI
-
Women being pregnant or nursing
-
The individual is known to be intolerant of the materials used in the implant or other required accessories
-
Absence of cochlear development
-
The cause of deafness is non-functionality of the auditory nerve and/or the upper auditory pathway
-
Medical contra-indications to middle ear and/or inner ear surgery, and/or anesthesia
-
External or middle ear infections are present
-
The tympanic membrane is perforated in the ear to be implanted
-
Anatomic abnormalities are present that would prevent appropriate placement of the stimulator housing in the bone of the skull, or prevent placement of the chosen electrode array into the cochlea (including ossification of the cochlea)
-
The psychological status of the individual is unstable
-
The individual has unrealistic expectations
-
Acute cholesteatoma
-
History of vestibular schwannoma
-
Unstable Meniere's disease
-
Auditory Neuropathy
-
Epilepsy not responding to treatment
-
Permanent inability and/or unwillingness to participation in post-operative care and rehabilitation
-
Known intellectual disability and/or psychological diseases
-
Participation in other pharmacological clinical trials within four weeks prior to enrolment
-
Anything that, in the opinion of the Investigator, would
- place the subject at increased risk
- preclude the subject's full compliance with or completion of the study
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Nie dotyczy
- Model interwencyjny: Zadanie dla jednej grupy
- Maskowanie: Brak (otwarta etykieta)
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Eksperymentalny: TICI recipients
Participants in this clinical investigation will be implanted with an Mi2000 TICI totally cochlear implant |
Participants in this clinical investigation will receive a totally implantable cochlear implant. |
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Word Test in Quiet
Ramy czasowe: Pre-op to 6 months after first fitting
|
Word recognition in quiet, on a scale from 0 to 100% correct, higher scores indicate better outcomes |
Pre-op to 6 months after first fitting
|
|
Sentence Test in Noise
Ramy czasowe: Pre-op to 6 months after first fitting
|
Oldenburg Matrix Test, results measured in dB signal-to-noise ratio (SNR) with a range of +30 to -10 dB SNR, lower values indicating better outcomes |
Pre-op to 6 months after first fitting
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Health Utility Index Mark 3 (HUI3)
Ramy czasowe: Pre-op to 6 months after first fitting
|
Health utility scale: 1.00: Perfect health. 0.00: Death. Negative values: States worse than death. |
Pre-op to 6 months after first fitting
|
|
Nijmegen Cochlear Implant Questionnaire (NCIQ)
Ramy czasowe: Pre-op to 6 months after first fitting
|
Disease specific Quality of Life, overall score is on a scale from 0 to 100, higher numbers indicating better outcomes |
Pre-op to 6 months after first fitting
|
|
Change in body sound perception
Ramy czasowe: through study completion, an average of 12 months after first fitting
|
Participant reported scale on body sound perception (0 - no disturbance to 10 - very disturbing) |
through study completion, an average of 12 months after first fitting
|
|
Change in stigma perception
Ramy czasowe: through study completion, an average of 12 months after first fitting
|
Participant reported scale on stigma perception (0 - no stigmatization to 10 - strong stigmatization) |
through study completion, an average of 12 months after first fitting
|
|
Change in comfort perception
Ramy czasowe: through study completion, an average of 12 months after first fitting
|
Participant reported scale on stigma perception (0 - not comfortable to 10 - very comfortable) |
through study completion, an average of 12 months after first fitting
|
Inne miary wyników
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Word test in quiet
Ramy czasowe: through study completion, an average of 12 months after first fitting
|
Word recognition in quiet, on a scale from 0 to 100% correct, higher scores indicate better outcomes |
through study completion, an average of 12 months after first fitting
|
|
Sentence Test in Noise
Ramy czasowe: through study completion, an average of 12 months after first fitting
|
Oldenburg Matrix Test, results measured in dB signal-to-noise ratio (SNR) with a range of +30 to -10 dB SNR, lower values indicating better outcomes |
through study completion, an average of 12 months after first fitting
|
|
Health Utility Index Mark 3 (HUI3)
Ramy czasowe: through study completion, an average of 12 months after first fitting
|
Health utility scale: 1.00: Perfect health. 0.00: Death. Negative values: States worse than death. |
through study completion, an average of 12 months after first fitting
|
|
Nijmegen Cochlear Implant Questionnaire (NCIQ)
Ramy czasowe: through study completion, an average of 12 months after first fitting
|
Disease specific Quality of Life, overall score is on a scale from 0 to 100, higher numbers indicating better outcomes |
through study completion, an average of 12 months after first fitting
|
|
Speech, Spatial, Quality of Hearing (SSQ12)
Ramy czasowe: through study completion, an average of 12 months after first fitting
|
Speech, Spatial and Quality of hearing scale from 0 to 10, higher numbers indicating better outcomes |
through study completion, an average of 12 months after first fitting
|
|
Hearing Implant Sound Quality Index (HISQUI)
Ramy czasowe: through study completion, an average of 12 months after first fitting
|
Sound quality score ranging from 19 (very poor sound quality) to 133 (very good sound quality) |
through study completion, an average of 12 months after first fitting
|
|
Tinnitus Functional Index (TFI)
Ramy czasowe: through study completion, an average of 12 months after first fitting
|
Tinnitus questionnaire measures the severity and negative impact of tinnitus on a 0 (Not a Problem / Slight Tinnitus) to 100 (Very Big Problem / Very Severe Tinnitus) scale |
through study completion, an average of 12 months after first fitting
|
|
Audiogram
Ramy czasowe: through study completion, an average of 12 months after first fitting
|
Pure-tone air-conduction hearing thresholds will be measured in each ear. The threshold is the lowest sound level, in decibels hearing level (dB HL), at which the participant responds. The outcome is the threshold at each frequency. Higher thresholds mean poorer hearing; lower thresholds better hearing. |
through study completion, an average of 12 months after first fitting
|
Współpracownicy i badacze
Śledczy
- Dyrektor Studium: Florian Schwarze, MED-EL
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Szacowany)
Ukończenie studiów (Szacowany)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
- Objawy neurologiczne
- Choroby Układu Nerwowego
- Choroby otorynolaryngologiczne
- Zaburzenia czucia
- Choroby uszu
- Zaburzenia słuchu
- Stany patologiczne, oznaki i objawy
- Objawy i symptomy
- Utrata słuchu
- Procedury chirurgiczne, operacyjny
- Implantacja protezy
- Otorhinolaryngologiczne procedury chirurgiczne
- Otologiczne procedury chirurgiczne
- Implantacja Cochlear
Inne numery identyfikacyjne badania
- MED-EL_CRD_2026_03
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
produkt wyprodukowany i wyeksportowany z USA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .