Denne siden ble automatisk oversatt og nøyaktigheten av oversettelsen er ikke garantert. Vennligst referer til engelsk versjon for en kildetekst.

Impact of Volume Imaging Using Diagnostic Ultrasound

19. desember 2017 oppdatert av: Jon Jacobson, University of Michigan

Impact of Volume Imaging With Ultrasound

Determine if volume imaging can diagnose bone, ligament, muscle injuries.

Studieoversikt

Detaljert beskrivelse

The investigators are attempting to determine if Volume imaging (a new type of ultrasound imaging)can accurately diagnose injuries of the muscle ligaments, tendons and bones when compared to conventional ultrasound imaging.

Studietype

Intervensjonell

Registrering (Faktiske)

16

Fase

  • Ikke aktuelt

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiesteder

    • Michigan
      • Ann Arbor, Michigan, Forente stater, 48109
        • University of Michigan

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

18 år og eldre (Voksen, Eldre voksen)

Tar imot friske frivillige

Nei

Kjønn som er kvalifisert for studier

Alle

Beskrivelse

Inclusion Criteria:

  • Age 18 or older
  • Must be scheduled to have a musculoskeletal (bone, ligament, muscle, tendon) ultrasound performed as part of their routine clinical care.

Exclusion Criteria:

  • Unable to lie flat on ultrasound table.
  • Subjects under 18 years of age

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

  • Primært formål: Diagnostisk
  • Tildeling: N/A
  • Intervensjonsmodell: Enkeltgruppeoppdrag
  • Masking: Ingen (Open Label)

Våpen og intervensjoner

Deltakergruppe / Arm
Intervensjon / Behandling
Eksperimentell: Volume Imaging scan
New type of ultrasound scan using General Electric US scanner, Model is a GE Logiq E9.
Subject will be required to lie flat for no longer than 3 minutes to complete a volume imaging ultrasound scan of the injured area. Following the volume imaging scan a conventional ultrasound scan will be completed as ordered by their clinician.
Andre navn:
  • Volumetric Ultrasound
  • 3D Ultrasound Imaging
  • Volume Imaging
The subject will be required to lie flat for approximately 5 to 10 minutes to complete a conventional ultrasound scan to x-ray the muscle and tendon injuries.

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Accuracy of 3D Ultrasound Scanning Expressed as Percent Correlation Between Images From Conventional Ultrasound and Volume Imaging
Tidsramme: Up to 13 minutes
Both ultrasound and volume imaging scans were done on the same day. For all scanned patients, the ultrasound technologist took a volume of images focusing where the patient had symptoms. The study PI reviewed the images, then went back in to do second scan. It took 5 to 10 minutes to complete a conventional ultrasound scan and up to 3 minutes to complete a volume imaging ultrasound scan.
Up to 13 minutes

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Etterforskere

  • Hovedetterforsker: Jon Jacobson, M.D., University of Michigan Hospital

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart

1. august 2009

Primær fullføring (Faktiske)

1. mars 2010

Studiet fullført (Faktiske)

1. mai 2010

Datoer for studieregistrering

Først innsendt

1. mai 2012

Først innsendt som oppfylte QC-kriteriene

17. mai 2012

Først lagt ut (Anslag)

18. mai 2012

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

19. januar 2018

Siste oppdatering sendt inn som oppfylte QC-kriteriene

19. desember 2017

Sist bekreftet

1. desember 2017

Mer informasjon

Begreper knyttet til denne studien

Ytterligere relevante MeSH-vilkår

Andre studie-ID-numre

  • HUM00030780

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .

Abonnere