Denne siden ble automatisk oversatt og nøyaktigheten av oversettelsen er ikke garantert. Vennligst referer til engelsk versjon for en kildetekst.

Comparison of Visual Outcomes After Implantation of the POD FT and the POD F (PoyPODF/FT)

29. juni 2021 oppdatert av: Beaver-Visitec International, Inc.

Comparison of Visual Outcomes After Implantation of the POD 26P AY FT (PhysIOL) and the POD 26P AY F (PhysIOL)

There is no difference of the photic phenomena in the two groups.

The study will be a prospective non-randomised controlled study. The target is then to determine the equivalence in the glare. Assumption of Type I error is p=0.05 as level of significance and Type II error is alpha=0.8 as power.

Studieoversikt

Status

Fullført

Forhold

Detaljert beskrivelse

The study will be a prospective non-randomised controlled study. The target is then to determine the equivalence in the glare. Assumption of Type I error is p=0.05 as level of significance and Type II error is alpha=0.8 as power.

We used the 'TrialSize' package of the R software. Here are the parameters defined for the sample size calculation:

  1. Alpha: 0.05
  2. Power : 0.90
  3. Two sided test
  4. Equal group allocation
  5. Standard deviation for the two groups (POD 26P AY F et POD 26P AY FT) equal to 0.10
  6. Expected mean for the two groups (POD 26P AY F et POD 26P AY FT) equal to 0.89 (true difference between the means equal 0)
  7. An equivalence limit of 0.05, 0.10 and 0.15 Equivalence limit: 0.15 In order to show no difference between these two groups, 12 patients by groups are needed. With a drop-out of 15%, we obtain 30 patients (15 patients by group) to recruit in order to obtain 24 valuable patients.

Equivalence limit: 0.10 In order to show no difference between these two groups, 26 patients by groups are needed. With a drop-out of 15%, we obtain 62 patients (31 patients by group) to recruit in order to obtain 52 valuable patients.

This total number of subjects with such requirement is 26 patients in each group.

Group 1 will be made of 26 patients with corneal astigmatism higher than 1.0D in both eyes and lower than 2.5D and will be implanted with the POD 26P AY FT and Group 2 will be made of 26 patients with corneal astigmatism lower than 1.0D in both eyes.

Interim analysis after the 12th patient of each group will have completed the last follow-up will be achieved to confirm the equivalence with the equivalence limit of 0.15.

The POD platform in 26 % (non toric version) is available since 2008 in the monofocal version and since 2012 in the toric one (POD 6P AY T, Ankoris®, PhysIOL).The so-called POD design is characterised by two symmetrical bifid haptics with opened loops that provide four points of support to ensure IOL stability in the capsular bag. The dual C-loop profile shortens the loops, thus improving the pliability of the implant during its injection through a micro-incision. These shortened loops should permit a clockwise or anticlockwise rotary motion and should facilitate the comfortable fitting of the implant orientation after unfolding without elastic-restoring torque. The double C-loop POD design offers 4 support points for the implant within the capsule and ensures its stability. The V-shape of the upper and lower haptics together with the flexibility of the implant allow the loop separation angle to be adjusted and ensure the most accurate adaptation to the capsular bag size. A finite element structural analysis of the implant showed that the elasticity at the distal part of the loop prevents the constraints from being transmitted onto the optical portion of the implant. The trifocal optic is associated to the POD platform and is made of 26 % raw material.

The rotational stability of this non toric version has been clinically investigated on 117 consecutive eyes 1 week, 3 weeks, 3 and 12 months after implantation. The absolute rotation of the lens averaged 2.5 ± 2.6°. The position of the center of the implant relative to the pupillary center expressed by a vector was 0.01 mm at 70°.

The investigational product (POD 26P AY FT) is CE labeled since January 2014. Main IOL features are:

  • Biconvex toric aspheric (-0.11um SA) blue-blocking, hydrophilic acrylic IOL with 26% equlibrium water content, implantable through ≥ 2.2mm incision.
  • 4-point haptic design
  • 6 mm of optical diameter / 11.4 mm of total diameter
  • Dioptric range (SE): 6 to 35 D by 0.5 D increments
  • Cylinders at the IOL plane: 1, 1.5, 2.25, 3, 3.75, 4.5, 5.25, 6 D
  • Addition +1.75D / +3.5 D

The control product (POD 26P AY F) is CE labeled since 2010. Main IOL features are:

  • Biconvex, aspheric (-0.11um SA) blue-blocking, hydrophilic acrylic IOL with 26% equlibrium water content, implantable through ≥ 2.2mm incision.
  • 4-point haptics design which minimizes decentration and optimizes the rotational stability
  • 6 mm of optical diameter / 11.4 mm of total diameter
  • Dioptric range (SE): 6 to 35 D by 0.5 D increments
  • Addition +1.75D / +3.5 D

Studietype

Observasjonsmessig

Registrering (Faktiske)

63

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiesteder

      • Madrid, Spania, 28040
        • Hospital Clinico San Carlos

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

21 år og eldre (Voksen, Eldre voksen)

Tar imot friske frivillige

Nei

Kjønn som er kvalifisert for studier

Alle

Prøvetakingsmetode

Ikke-sannsynlighetsprøve

Studiepopulasjon

The study population consists of patients undergoing routine cataract surgery. The study participants receive a bilateral implantation of trifocal intraocular lenses. Depending on the preoperative corneal astigmatism, the patients receive either non-toric trifocal IOLs (POD F) or toric trifocal IOLs (POD FT) in both eyes.

Beskrivelse

Inclusion Criteria:

  • Age-related cataract
  • Preoperative Corneal astigmatism < 0.75 D
  • Age 21 and older
  • Visual Acuity > 0.05
  • Normal findings in the medical history and physical examination unless the investigator considers an abnormality to be clinically irrelevant.
  • Patient willing multifocal implantation and with realistic expectations.

Exclusion Criteria:

  • Relevant other ophthalmic diseases such as pseudoexfoliation syndrome, floppy iris syndrome, corneal pathologies, retinal pathology (diabetic maculopathy, myopic maculopathy, age related macular degeneration...)
  • Previous ocular surgery or trauma.

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

  • Observasjonsmodeller: Case-Control
  • Tidsperspektiver: Potensielle

Kohorter og intervensjoner

Gruppe / Kohort
Intervensjon / Behandling
POD 26P AY FT
26 patients with corneal astigmatism higher than 1.0D in both eyes and lower than 2.5D and will be implanted with the POD 26P AY FT
Routine cataract surgery
POD 26P AY F
26 patients with corneal astigmatism lower than 1.0D in both eyes will be implanted with the POD 26P AY F
Routine cataract surgery

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Determine the equivalence of the glare
Tidsramme: 3 Months
The primary endpoint is to show statistically equivalent outcomes on glare at the 3 months follow up visit. A significance level of p = 0.05 will be considered statistically significant.
3 Months

Sekundære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Measurement of far, intermediate and near visual acuity
Tidsramme: 6 Months
The secondary objective is to measure far, intermediate and near visual acuity of the POD AY 26P FT with respect to the POD AY 26P F.
6 Months
Refraction
Tidsramme: 6 Months
The secondary objective is to measure the refraction of the POD AY 26P FT with respect to the POD AY 26P F.
6 Months
Centration
Tidsramme: 6 Months
The secondary objective is to measure the centration of the POD AY 26P FT with respect to the POD AY 26P F.
6 Months
Rotational stability
Tidsramme: 6 Months
The secondary objective is to measure the rotational stability of the POD AY 26P FT with respect to the POD AY 26P F.
6 Months
Equivalence of the visual acuity and the contrast sensitivity
Tidsramme: 6 Months
The secondary objective is to determine the equivalence of the visual acuity of the POD AY 26P FT with respect to the POD AY 26P F.
6 Months
Equivalence of the visual acuity and the contrast sensitivity
Tidsramme: 6 Months
The secondary objective is to determine the contrast sensitivity at far of the POD AY 26P FT with respect to the POD AY 26P F.
6 Months

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Etterforskere

  • Hovedetterforsker: Francisco Poyales Galan, PhD, CEIC Hospital Clinical San Carlos

Publikasjoner og nyttige lenker

Den som er ansvarlig for å legge inn informasjon om studien leverer frivillig disse publikasjonene. Disse kan handle om alt relatert til studiet.

Generelle publikasjoner

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Faktiske)

16. juli 2014

Primær fullføring (Faktiske)

20. juli 2017

Studiet fullført (Faktiske)

20. juli 2017

Datoer for studieregistrering

Først innsendt

18. juni 2021

Først innsendt som oppfylte QC-kriteriene

21. juni 2021

Først lagt ut (Faktiske)

29. juni 2021

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

1. juli 2021

Siste oppdatering sendt inn som oppfylte QC-kriteriene

29. juni 2021

Sist bekreftet

1. juni 2021

Mer informasjon

Begreper knyttet til denne studien

Ytterligere relevante MeSH-vilkår

Andre studie-ID-numre

  • Poyales/POD FT - POD F

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

Nei

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .

Abonnere