- ICH GCP
- US Clinical Trials Registry
- Klinisk utprøving NCT07659041
Effectiveness, Patient Acceptance, and Cost Estimation of 3D-printed Retainer Compared to Hawley Retainer in Expansion Case: a Randomized Controlled Trial
Studieoversikt
Status
Intervensjon / Behandling
Detaljert beskrivelse
Studietype
Registrering (Antatt)
Fase
- Ikke aktuelt
Kontakter og plasseringer
Studiekontakt
- Navn: Asma Ashari, BDS Adel, MClinDent Lon, MOrth
- Telefonnummer: +603 8921 5555
- E-post: asmaashari@ukm.edu.my
Studer Kontakt Backup
- Navn: ALIZAE MARNY FADZLIN SYED MOHAMED
- Telefonnummer: +6038921 5555
- E-post: alizaemarny@ukm.edu.my
Studiesteder
-
-
Kuala Lumpur
-
Kuala Lumpur, Kuala Lumpur, Malaysia, 50300
- National University of Malaysia
-
Ta kontakt med:
- Fakulti pergigian UKM
- Telefonnummer: +6039289 7741
- E-post: asmaashari@ukm.edu.my
-
Hovedetterforsker:
- Mei Ling Cheng
-
Kuala Lumpur, Kuala Lumpur, Malaysia, 50603
- University Malaya
-
Ta kontakt med:
- May Nak Lau
- Telefonnummer: +60379674802
- E-post: minalau@um.edu.my
-
Underetterforsker:
- Zhang Yi Tan
-
-
Selangor
-
Sungai Buloh, Selangor, Malaysia, 47000
- University Teknologi Mara Selangor branch
-
Ta kontakt med:
- Nik Mukhriz Nik Mustapha
- Telefonnummer: +6036126 6103
- E-post: nikmukhriz@uitm.edu.my
-
Underetterforsker:
- Siti Nor Hafizah Salehun
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
- Barn
- Voksen
- Eldre voksen
Tar imot friske frivillige
Beskrivelse
Inclusion Criteria:
- Patients aged 16 years or older at the time of debonding
- Treatment plan of extraction or non-extraction followed by straight wire appliances in the upper arch only or both arches
- Undergone expansion treatment in the upper arch causing an arch width increase of 3-10mm, either using a Quadhelix, expansion with archwires, or URA with midline screw
- Had pretreatment dental cast
- Had no chronic medical condition.
Exclusion Criteria:
- Cleft lip and palate
- Chronic medical conditions
- Broken teeth or bubbles on study model at site of measurement.
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Annen
- Tildeling: Randomisert
- Intervensjonsmodell: Parallell tildeling
- Masking: Enkelt
Våpen og intervensjoner
Deltakergruppe / Arm |
Intervensjon / Behandling |
|---|---|
|
Aktiv komparator: Hawley retainer
A screening will be done to select suitable patients for the study.
Only patients who fulfil the criteria will be invited to participate in this study.
Following informed consent, eligible subjects will be randomly allocated into one of two groups wither hawley retainer or 3D printed retainer.
Fabrication of Hawley retainers will be done using a standardized design across all centres.
|
Hawley retainers have served as the established standard for retention after maxillary expansion.
Standard design of Hawley Retainer: - Labial bow (0.8mm hard stainless steel) from canine to canine - Adam clasp on the molar (0.7mm hard stainless steel) - acrylic baseplate (2-3mm thickness) .
|
|
Eksperimentell: 3D printed retainer
A screening will be done to select suitable patients for the study.
Only patients who fulfil the criteria will be invited to participate in this study.
Following informed consent, eligible subjects will be randomly allocated into one of two groups wither hawley retainer or 3D printed retainer.
Fabrication of 3d printed retainers will be done using a standardized design at one main centres by one technician using Nextdent Orhtoflex Resin.
|
3D-printed retainer Using Nextdent Orthoflex resin Standard design of 3D printed retainer:
|
Hva måler studien?
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Retention of the maxillary expansion
Tidsramme: 12 months
|
|
12 months
|
Sekundære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Patient acceptance
Tidsramme: 12 months
|
Subjects will be given and asked to complete a questionnaire on patient acceptance (see attachment) at 6 and 12 months post-debond. The Questionnaire has been validated and published by (Saw et al. 2025). It uses a Visual Analogue Scale (VAS) to ask six questions related to subject acceptance of orthodontic retainers in fitting, speech, appearance, oral hygiene, durability, and comfort. Refer to Attachment 1 (Malay version) and Attachment 2 (English Version) for the questionnaires. |
12 months
|
|
cost estimation
Tidsramme: 6 months
|
To estimate and compare the costs associated with the implementation and provision of 3D-printed retainers between clinics with existing in-house 3D-printing facilities and clinics planning to acquire 3D-printing services.
The analysis will include direct costs such as equipment acquisition, materials, software, maintenance, laboratory procedures, and staff chairside time.
|
6 months
|
Samarbeidspartnere og etterforskere
Sponsor
Etterforskere
- Studieleder: Asma Ashari, MClinDent Lon, National University of Malaysia
Publikasjoner og nyttige lenker
Generelle publikasjoner
- Hichens L, Rowland H, Williams A, Hollinghurst S, Ewings P, Clark S, Ireland A, Sandy J. Cost-effectiveness and patient satisfaction: Hawley and vacuum-formed retainers. Eur J Orthod. 2007 Aug;29(4):372-8. doi: 10.1093/ejo/cjm039.
- Naeem OA, Bencharit S, Yang IH, Stilianoudakis SC, Carrico C, Tufekci E. Comparison of 3-dimensional printing technologies on the precision, trueness, and accuracy of printed retainers. Am J Orthod Dentofacial Orthop. 2022 Apr;161(4):582-591. doi: 10.1016/j.ajodo.2021.03.016.
- Firlej M, Zaborowicz K, Zaborowicz M, Firlej E, Domagala I, Pieniak D, Igielska-Kalwat J, Dmowski A, Biedziak B. Mechanical Properties of 3D Printed Orthodontic Retainers. Int J Environ Res Public Health. 2022 May 9;19(9):5775. doi: 10.3390/ijerph19095775.
- Tsoukala E, Lyros I, Tsolakis AI, Maroulakos MP, Tsolakis IA. Direct 3D-Printed Orthodontic Retainers. A Systematic Review. Children (Basel). 2023 Apr 3;10(4):676. doi: 10.3390/children10040676.
- Saw ZK, Yuen JJX, Ashari A, Ibrahim Bahemia F, Low YX, Nik Mustapha NM, Lau MN. Forward-backward translation, content validity, face validity, construct validity, criterion validity, test-retest reliability, and internal consistency of a questionnaire on patient acceptance of orthodontic retainer. PLoS One. 2025 Jan 3;20(1):e0314853. doi: 10.1371/journal.pone.0314853. eCollection 2025.
- Nakornnoi T, Bunjerdjin P, Santiwong P, Sipiyaruk K, Neoh SP, Chintavalakorn R. The Influence of Thickness on the Mechanical Behaviors of 3D Printing Resins for Orthodontic Retainers. Int J Biomater. 2024 Jun 25;2024:7398478. doi: 10.1155/2024/7398478. eCollection 2024.
- Ashari A, Xian L, Syed Mohamed AMF, Wahab RMA, Kit YC, Tata MD, Sinnasamy S, Kuppusamy E. One-year comparative assessment of retention of arch width increases between modified vacuum-formed and Hawley retainers. Angle Orthod. 2022 Mar 1;92(2):197-203. doi: 10.2319/050921-363.1.
- Ashari A, Nik Mustapha NM, Yuen JJX, Saw ZK, Lau MN, Xian L, Syed Mohamed AMF, Megat Abdul Wahab R, Yeoh CK, Deva Tata M, Sinnasamy S. A two-year comparative assessment of retention of arch width increases between modified vacuum-formed and Hawley retainers: a multi-center randomized clinical trial. Prog Orthod. 2022 Aug 26;23(1):40. doi: 10.1186/s40510-022-00424-5.
- Stoev YY, Uzunov TT, Stoyanova NS, Grozdanova-Uzunova RG, Kosturkov DN, Taneva IK. Mechanical properties of materials for 3D printed orthodontic retainers. Folia Med (Plovdiv). 2023 Dec 31;65(6):986-992. doi: 10.3897/folmed.65.e107299.
- Neoh SP, Khantachawana A, Chintavalakorn R, Santiwong P, Srikhirin T. Comparison of physical, mechanical, and optical properties between thermoplastic materials and 3-dimensional printing resins for orthodontic clear retainers. Am J Orthod Dentofacial Orthop. 2025 Jan;167(1):95-109.e1. doi: 10.1016/j.ajodo.2024.06.010.
Studierekorddatoer
Studer hoveddatoer
Studiestart (Antatt)
Primær fullføring (Antatt)
Studiet fullført (Antatt)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Nøkkelord
Andre studie-ID-numre
- JEP 2025-630 (Annen identifikator: National university of Malaysia)
Plan for individuelle deltakerdata (IPD)
Planlegger du å dele individuelle deltakerdata (IPD)?
IPD-planbeskrivelse
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Studerer et amerikansk FDA-regulert enhetsprodukt
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .