- ICH GCP
- US Clinical Trials Registry
- Klinisk utprøving NCT07664813
One-Click Autofocus Versus Segmented Focus in Gastric Endoscopy
A Comparative Study of One-Click Autofocus Versus Segmented Focus Techniques Under Magnifying Endoscopy for Gastric Diseases: A Tandem Randomized Controlled Trial
Magnifying endoscopy provides high-resolution images that enhance the detection of early gastrointestinal lesions. However, conventional manual zoom techniques require frequent focal adjustments, which can be technically demanding and may compromise image stability, especially in complex anatomical settings.
This study evaluates a novel one-click autofocus system based on image recognition and computer vision algorithms. The system automatically adjusts focal distance within seconds, eliminating the need for manual operation. This trial aims to compare the efficiency and image quality of one-click autofocus versus segmented manual focus in patients undergoing magnifying endoscopy for gastric diseases.
A tandem randomized controlled trial will be conducted to assess procedure time, image clarity score, and operator satisfaction between the two techniques.
Studieoversikt
Status
Forhold
Intervensjon / Behandling
Studietype
Registrering (Antatt)
Fase
- Ikke aktuelt
Kontakter og plasseringer
Studiekontakt
- Navn: Rui Ji, MD PHD
- Telefonnummer: +86-18560086103
- E-post: qljirui@email.sdu.edu.cn
Studiesteder
-
-
Shandong
-
Jinan, Shandong, Kina, 250012
- Qilu Hospital of Shandong University
-
Ta kontakt med:
- Rui Ji, MD PHD
- Telefonnummer: +86-18560086103
- E-post: qljirui@email.sdu.edu.cn
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
- Voksen
- Eldre voksen
Tar imot friske frivillige
Beskrivelse
Inclusion Criteria:
- Age ≥ 18 years
- Patients with gastric diseases (e.g., suspicious lesions, known gastric disorders) requiring further magnifying endoscopy examination
- Ability to understand and provide written informed consent voluntarily
Exclusion Criteria:
- Absolute contraindications to upper gastrointestinal endoscopy (e.g., severe cardiopulmonary insufficiency, coagulopathy)
- Pregnant or lactating women
- History of gastric surgery (e.g., gastrectomy) that may affect endoscopic manipulation or anatomy
Studieplan
Hvordan er studiet utformet?
Designdetaljer
- Primært formål: Diagnostisk
- Tildeling: Randomisert
- Intervensjonsmodell: Crossover-oppdrag
- Masking: Enkelt
Våpen og intervensjoner
Deltakergruppe / Arm |
Intervensjon / Behandling |
|---|---|
|
Eksperimentell: One-Click Autofocus followed by Segmented Focus
Participants receive one-click autofocus examination first, followed by segmented focus examination.
Both examinations are performed during the same endoscopic session.
The order of the two techniques is randomized.
|
Magnifying endoscopy examination performed using the one-click autofocus mode.
The system automatically adjusts focus to the optimal plane with a single button press.
Magnifying endoscopy examination performed using the segmented focus mode.
The endoscopist manually adjusts the focus level stepwise through multiple pre-set focal planes.
|
|
Aktiv komparator: Segmented Focus followed by One-Click Autofocus
Participants receive segmented focus examination first, followed by one-click autofocus examination.
Both examinations are performed during the same endoscopic session.
The order of the two techniques is randomized.
|
Magnifying endoscopy examination performed using the one-click autofocus mode.
The system automatically adjusts focus to the optimal plane with a single button press.
Magnifying endoscopy examination performed using the segmented focus mode.
The endoscopist manually adjusts the focus level stepwise through multiple pre-set focal planes.
|
Hva måler studien?
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Image Quality Quantification by Edge Detection Analysis
Tidsramme: Day 1 (During the endoscopic examination)
|
Image quality is objectively quantified using edge detection analysis applied to standardized images captured by each technique.
The standard deviation of pixel intensity after edge detection processing is used as the quantitative metric.
A higher standard deviation indicates higher image contrast and edge definition, reflecting superior image quality.
All image analyses are performed offline by an independent researcher blinded to the technique used.
|
Day 1 (During the endoscopic examination)
|
Sekundære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Subjective Image Quality Assessment by Blinded Expert Review
Tidsramme: Day 1 (During the endoscopic examination)
|
Image quality is subjectively assessed by two to three independent expert reviewers blinded to the technique used.
Recorded videos of magnifying endoscopy examinations are reviewed offline and scored using a 5-point Likert scale, where 1 = poor and 5 = excellent.
Higher scores indicate superior image quality.
The final score for each image is the average of the reviewers' scores.
|
Day 1 (During the endoscopic examination)
|
|
Image Acquisition Time per Capture
Tidsramme: Day 1 (During the endoscopic examination)
|
Time (in seconds) measured for each image acquisition, defined as the duration from the moment the endoscope makes contact with the target gastric mucosa to the capture of the final magnified image for each technique.
|
Day 1 (During the endoscopic examination)
|
Samarbeidspartnere og etterforskere
Sponsor
Studierekorddatoer
Studer hoveddatoer
Studiestart (Antatt)
Primær fullføring (Antatt)
Studiet fullført (Antatt)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Ytterligere relevante MeSH-vilkår
Andre studie-ID-numre
- KYLL-2026-01(YJ)-072
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Studerer et amerikansk FDA-regulert enhetsprodukt
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .