- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT00915148
Ultrasound Prediction of Prolonged Labour
First Stage 3D-ultrasound During Prolonged Labour.
Przegląd badań
Status
Warunki
Interwencja / Leczenie
Szczegółowy opis
AIM:
To correlate findings on ultrasound with manual palpation, and to consider if delivery outcome can be predicted with help of ultrasound. Specifically evaluate the significance of fetal head level (descent) in the pelvis, measured with ultrasound.
Objective:
Labours have traditionally been evaluated by manuals methods of the "delivery helper" - midwives or doctor. There are many factors that will prolong labour such as malcontractions, disproportion of the birth canal and malpresentation/position. In about 20% of primigravidae, the first stage will last longer than 10 hours.
In this study we want to evaluate different ultrasounds measurements to see if ultrasound can be used to predict the outcome of labour.
Methods:
A descriptive observational study, with one ultrasound examination. The labour will be handled according to definitions by Woman's department, Stavanger University Hospital, and WHO.
The use of stimulating agents, as Oxytocin, will be evaluated after manual examinations, specific definitions and criteria.
The results of the ultrasound examinations will be evaluated after the delivery, since the results are not to be used clinically during the delivery.
Inclusion criteria will be primigravidae, with one fetus, after the 37th week. Feta head presentation. Ruptured membranes, at least one hour before inclusion. Prolonged first stage according to WHO definitions. The target is to include 100 subjects.
Inter- and intraobserver variation will be evaluated with intraclass coefficients. We will analyze operative delivery with normal vaginal delivery. Also, two groups divided by the stage 0 will be evaluated with statistics analyzes.
Time to delivery will be evaluated with Kaplan Meier and Cox regression analyzes.
Typ studiów
Zapisy (Rzeczywisty)
Kontakty i lokalizacje
Lokalizacje studiów
-
-
-
Stavanger, Norwegia, NO-4011
- Stavanger University Hospital
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dziecko
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Metoda próbkowania
Badana populacja
Opis
Inclusion Criteria:
- Primi gravidae
- >37th week
- Cephalic presentation
- Prolonged first stage according to WHO definitions.
Exclusion Criteria:
- Multiple pregnancies
- Intrauterine fetal death
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
Kohorty i interwencje
Grupa / Kohorta |
Interwencja / Leczenie |
|---|---|
|
Ultrasound examination
Women with prolonged Labour; Primi gravidae, single pregnancy, >37 weeks, fetus alive, cephalic presentation.
|
Trans-abdominal and trans-perineal 3D ultrasound examination
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Area Under the Receiver Operating Curve (ROC AUC) Values for Prediction of Vaginal Delivery Using 2D or 3D Ulrasound
Ramy czasowe: during labor
|
Fetal Head descent was first measured as the shortest distance between the outer bony limit of the fetal skull and the Perineum.
Fetal head descent was re-assessed by measuring the angle of progression in a mid-sagittal plane.
Fetal head-perineum distance was evaluated with using a cut-off of ≤40 mm, while the angle of progression was evaluated using a cut off of ≥ 110 degrees.
The ROC curves plotted the percentage sensitivity against the percentage false positive rate for head-perineum distance and angle of progression as measured by ultrasound.
|
during labor
|
Miary wyników drugorzędnych
Miara wyniku |
Ramy czasowe |
|---|---|
|
Percentage of Women With Delivery Within 6 Hours From Defined Prolonged Labor (in Accordance With WHO Recommendations)
Ramy czasowe: 6 hours post determination of prolonged labor
|
6 hours post determination of prolonged labor
|
Współpracownicy i badacze
Sponsor
Śledczy
- Główny śledczy: Erik Andreas Torkildsen, MD, Helse Stavanger HF
- Dyrektor Studium: Torbjørn Moe Eggebø, MD, PhD, Helse Stavanger HF
Publikacje i pomocne linki
Publikacje ogólne
- Eggebo TM, Heien C, Okland I, Gjessing LK, Romundstad P, Salvesen KA. Ultrasound assessment of fetal head-perineum distance before induction of labor. Ultrasound Obstet Gynecol. 2008 Aug;32(2):199-204. doi: 10.1002/uog.5360.
- Henrich W, Dudenhausen J, Fuchs I, Kamena A, Tutschek B. Intrapartum translabial ultrasound (ITU): sonographic landmarks and correlation with successful vacuum extraction. Ultrasound Obstet Gynecol. 2006 Nov;28(6):753-60. doi: 10.1002/uog.3848.
- Barbera AF, Pombar X, Perugino G, Lezotte DC, Hobbins JC. A new method to assess fetal head descent in labor with transperineal ultrasound. Ultrasound Obstet Gynecol. 2009 Mar;33(3):313-9. doi: 10.1002/uog.6329.
- Eggebo TM, Gjessing LK, Heien C, Smedvig E, Okland I, Romundstad P, Salvesen KA. Prediction of labor and delivery by transperineal ultrasound in pregnancies with prelabor rupture of membranes at term. Ultrasound Obstet Gynecol. 2006 Apr;27(4):387-91. doi: 10.1002/uog.2744.
- Eggebo TM, Heien C, Okland I, Gjessing LK, Smedvig E, Romundstad P, Salvesen KA. Prediction of labour and delivery by ascertaining the fetal head position with transabdominal ultrasound in pregnancies with prelabour rupture of membranes after 37 weeks. Ultraschall Med. 2008 Apr;29(2):179-83. doi: 10.1055/s-2007-963017. Epub 2007 Jun 28.
- Torkildsen EA, Salvesen KA, Eggebo TM. Prediction of delivery mode with transperineal ultrasound in women with prolonged first stage of labor. Ultrasound Obstet Gynecol. 2011 Jun;37(6):702-8. doi: 10.1002/uog.8951. Epub 2011 May 3.
- Tutschek B, Torkildsen EA, Eggebo TM. Comparison between ultrasound parameters and clinical examination to assess fetal head station in labor. Ultrasound Obstet Gynecol. 2013 Apr;41(4):425-9. doi: 10.1002/uog.12422. Epub 2013 Mar 14.
- Torkildsen EA, Salvesen KA, Eggebo TM. Agreement between two- and three-dimensional transperineal ultrasound methods in assessing fetal head descent in the first stage of labor. Ultrasound Obstet Gynecol. 2012 Mar;39(3):310-5. doi: 10.1002/uog.9065.
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Oszacować)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Oszacować)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Inne numery identyfikacyjne badania
- StaHF500804
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .
Badania kliniczne na Przedłużająca się praca
-
Aydin Adnan Menderes UniversityZakończonyCzas pracy | Labor Bain | i Satysfakcja z Porodu Podczas Fizjologicznego Porodu Siłami NaturyTurcja (Türkiye)
Badania kliniczne na Ultrasound examination
-
Centre Hospitalier le MansJeszcze nie rekrutacjaUSG Dopplera | Olbrzymiokomórkowe zapalenie tętnic (GCA)Francja
-
Fujian Medical UniversityJeszcze nie rekrutacjaPrzerzuty limfatyczne | Nowotwory tarczycy | Rak brodawkowaty tarczycy | Mutacja protoonogenu retChiny
-
University Hospital, BordeauxJeszcze nie rekrutacjaCHD - wrodzona wada sercaFrancja
-
University Hospital, BordeauxRekrutacyjny
-
Veronique VidalRekrutacyjnyBól w pachwinie | Zaburzenia stawu biodrowegoSzwajcaria
-
The Netherlands Cancer InstituteZakończony
-
Sarasota Memorial Health Care SystemRejestracja na zaproszenieGuzek tarczycy | Guzki tarczycyStany Zjednoczone
-
Case Comprehensive Cancer CenterFocal One, INCWycofane
-
Hospices Civils de LyonZakończony
-
Assiut UniversityJeszcze nie rekrutacjaOcena pozycji wkładki sześć tygodni po wstawieniu | Umieszczenie i przemieszczenie urządzenia wewnątrzmacicznegoEgipt