Pilot Trial: Comparison of Flow Patterns

26 marca 2018 zaktualizowane przez: Alfred A Kocher, MD, Medical University of Vienna

Pilot Trial: Comparison of Flow Patterns. Is There a Difference Between sewed-in and "Sutureless" Bioprosthetic Aortic Heart Valves?

The purpose of this study is to determine why sutureless aortic bioprostheses apparently offer better haemodynamic properties compared to sewed-in aortic bioprostheses in patients who underwent aortic valve replacement.

Our approach to address this question is the combination of clinical data with the application of specifically validated experimental and computer based analyses to compare the performance of these valves under patient-specific conditions.

Przegląd badań

Typ studiów

Interwencyjne

Zapisy (Oczekiwany)

20

Faza

  • Nie dotyczy

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Lokalizacje studiów

      • Vienna, Austria, 1090
        • Rekrutacyjny
        • Medical University of Vienna
        • Kontakt:
        • Kontakt:
        • Główny śledczy:
          • Alfred Kocher, MD
        • Pod-śledczy:
          • Claus Rath, MD
        • Pod-śledczy:
          • Martin Andreas, MD
        • Pod-śledczy:
          • Dominik Wiedemann, MD
        • Pod-śledczy:
          • Guenther Laufer, MD
        • Pod-śledczy:
          • Christian Loewe, MD
        • Pod-śledczy:
          • Raphael Rosenhek, MD

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

18 lat i starsze (Dorosły, Starszy dorosły)

Akceptuje zdrowych ochotników

Nie

Płeć kwalifikująca się do nauki

Wszystko

Opis

Inclusion Criteria:

  • Patient underwent open aortic valve replacement with either an Edwards Magna Ease or an Edwards Intuity valve
  • Implanted valve size 23mm
  • Surgical access via full sternotomy or hemisternotomy
  • Intuity Valve System implanted by one of the clinical investigators of the TRITON trial (http://clinicaltrials.gov/show/NCT01445171) at the Medical University of Vienna
  • Post-operative ejection fraction ≥50%
  • Sinus-Rhythm
  • Ability to understand and comply with study procedures
  • Signed informed consent

Exclusion Criteria:

  • Under 18 years of age
  • Emergency surgery
  • Pregnancy
  • Previous aortic root replacement
  • Previous aortic valve replacement
  • Previous or concomitant root enlargement
  • Previous or concomitant repair of the ascending aorta
  • Paravalvular leakage
  • Ectasia of the ascending aorta
  • Previous or concomitant myomectomy
  • Concomitant replacement or repair of valves other than aortic
  • Usage of more than 3 sutures for implantation of the Intuity Valve System
  • Heavily calcified aortic root
  • Glomerular filtration rate (GFR) < 30 ml/min
  • Inability to understand or comply with study procedures
  • Known allergic reaction to iodinated, non-ionic contrast agents

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Inny
  • Przydział: Nielosowe
  • Model interwencyjny: Zadanie dla jednej grupy
  • Maskowanie: Brak (otwarta etykieta)

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Inny: "Sutureless" valve

Patients who underwent aortic valve replacement with a "sutureless" aortic valve.

An echocardiogram and a cardiac CT-scan will be conducted.

ECG gated CT angiography of the heart will be performed on a 128-slice dual-source and two Stellar detectors CT system with retrospective ECG-gating (Siemens/SOMATOM Definition Flash - Siemens, Germany, 100kV, 395.75 mAs).

In details, multi-phase images will be acquired to reconstruct between 10 and 100% of the cardiac cycle (10% increments) with a slice thickness of 1 mm. Examination will include left ventricular outflow tract, aortic root, coronary sinus, ascending aorta together with the prosthetic valves.

Inny: "Sewed-in" valve
Patients who underwent aortic valve replacement with a "sewed-in" aortic valve. An echocardiogram and a cardiac CT-scan will be conducted.

ECG gated CT angiography of the heart will be performed on a 128-slice dual-source and two Stellar detectors CT system with retrospective ECG-gating (Siemens/SOMATOM Definition Flash - Siemens, Germany, 100kV, 395.75 mAs).

In details, multi-phase images will be acquired to reconstruct between 10 and 100% of the cardiac cycle (10% increments) with a slice thickness of 1 mm. Examination will include left ventricular outflow tract, aortic root, coronary sinus, ascending aorta together with the prosthetic valves.

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Ramy czasowe
Comparison of maximum and minimum velocity under patient specific conditions
Ramy czasowe: between 6 months and 4 years after aortic valve replacement
between 6 months and 4 years after aortic valve replacement
Comparison of the effective orifice area under patient specific conditions
Ramy czasowe: between 6 months and 4 years after aortic valve replacement
between 6 months and 4 years after aortic valve replacement
Comparison of the percentage of turbulent flow under patient specific conditions
Ramy czasowe: between 6 months and 4 years after aortic valve replacement
between 6 months and 4 years after aortic valve replacement
Comparison of the pressure drop under patient specific conditions
Ramy czasowe: between 6 months and 4 years after aortic valve replacement
between 6 months and 4 years after aortic valve replacement

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Patient-specific, computer simulated pressure gradients compared to echocardiographically obtained pressure gradients.
Ramy czasowe: between 6 months and 4 years after aortic valve replacement

The first secondary outcome measure is the comparison of

-pressure gradients

as computed by the model against the same data collected standardly with echocardiographic technique. Differences will be quantified.

If positive (< 10%), this assessment would enhance the use of patient-specific models in clinics as a predictive tool for detailed haemodynamics."

between 6 months and 4 years after aortic valve replacement
Patient-specific, computer simulated peak velocity compared to echocardiographically obtained peak velocity.
Ramy czasowe: between 6 months and 4 years after aortic valve replacement

The second secondary outcome measure is the comparison of

-peak velocity

as computed by the model against the same data collected standardly with echocardiographic technique. Differences will be quantified.

If positive (< 10%), this assessment would enhance the use of patient-specific models in clinics as a predictive tool for detailed haemodynamics."

between 6 months and 4 years after aortic valve replacement

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Współpracownicy

Śledczy

  • Główny śledczy: Alfred Kocher, MD, Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów

1 października 2014

Zakończenie podstawowe (Oczekiwany)

1 grudnia 2020

Ukończenie studiów (Oczekiwany)

1 grudnia 2021

Daty rejestracji na studia

Pierwszy przesłany

22 października 2014

Pierwszy przesłany, który spełnia kryteria kontroli jakości

7 listopada 2014

Pierwszy wysłany (Oszacować)

11 listopada 2014

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

27 marca 2018

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

26 marca 2018

Ostatnia weryfikacja

1 marca 2018

Więcej informacji

Terminy związane z tym badaniem

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

produkt wyprodukowany i wyeksportowany z USA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Subskrybuj