- ICH GCP
- Registr klinických studií v USA
- Klinická studie NCT02288871
Pilot Trial: Comparison of Flow Patterns
Pilot Trial: Comparison of Flow Patterns. Is There a Difference Between sewed-in and "Sutureless" Bioprosthetic Aortic Heart Valves?
The purpose of this study is to determine why sutureless aortic bioprostheses apparently offer better haemodynamic properties compared to sewed-in aortic bioprostheses in patients who underwent aortic valve replacement.
Our approach to address this question is the combination of clinical data with the application of specifically validated experimental and computer based analyses to compare the performance of these valves under patient-specific conditions.
Přehled studie
Postavení
Intervence / Léčba
Typ studie
Zápis (Očekávaný)
Fáze
- Nelze použít
Kontakty a umístění
Studijní místa
-
-
-
Vienna, Rakousko, 1090
- Nábor
- Medical University of Vienna
-
Kontakt:
- Claus Rath, MD
- Telefonní číslo: 0043-1-40400-69660
- E-mail: claus.rath@meduniwien.ac.at
-
Kontakt:
- Alfred Kocher, MD
- Telefonní číslo: 0043-1-40400-69660
- E-mail: alfred.kocher@meduniwien.ac.at
-
Vrchní vyšetřovatel:
- Alfred Kocher, MD
-
Dílčí vyšetřovatel:
- Claus Rath, MD
-
Dílčí vyšetřovatel:
- Martin Andreas, MD
-
Dílčí vyšetřovatel:
- Dominik Wiedemann, MD
-
Dílčí vyšetřovatel:
- Guenther Laufer, MD
-
Dílčí vyšetřovatel:
- Christian Loewe, MD
-
Dílčí vyšetřovatel:
- Raphael Rosenhek, MD
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria:
- Patient underwent open aortic valve replacement with either an Edwards Magna Ease or an Edwards Intuity valve
- Implanted valve size 23mm
- Surgical access via full sternotomy or hemisternotomy
- Intuity Valve System implanted by one of the clinical investigators of the TRITON trial (http://clinicaltrials.gov/show/NCT01445171) at the Medical University of Vienna
- Post-operative ejection fraction ≥50%
- Sinus-Rhythm
- Ability to understand and comply with study procedures
- Signed informed consent
Exclusion Criteria:
- Under 18 years of age
- Emergency surgery
- Pregnancy
- Previous aortic root replacement
- Previous aortic valve replacement
- Previous or concomitant root enlargement
- Previous or concomitant repair of the ascending aorta
- Paravalvular leakage
- Ectasia of the ascending aorta
- Previous or concomitant myomectomy
- Concomitant replacement or repair of valves other than aortic
- Usage of more than 3 sutures for implantation of the Intuity Valve System
- Heavily calcified aortic root
- Glomerular filtration rate (GFR) < 30 ml/min
- Inability to understand or comply with study procedures
- Known allergic reaction to iodinated, non-ionic contrast agents
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Jiný
- Přidělení: Nerandomizované
- Intervenční model: Přiřazení jedné skupiny
- Maskování: Žádné (otevřený štítek)
Zbraně a zásahy
Skupina účastníků / Arm |
Intervence / Léčba |
|---|---|
|
Jiný: "Sutureless" valve
Patients who underwent aortic valve replacement with a "sutureless" aortic valve. An echocardiogram and a cardiac CT-scan will be conducted. |
ECG gated CT angiography of the heart will be performed on a 128-slice dual-source and two Stellar detectors CT system with retrospective ECG-gating (Siemens/SOMATOM Definition Flash - Siemens, Germany, 100kV, 395.75 mAs). In details, multi-phase images will be acquired to reconstruct between 10 and 100% of the cardiac cycle (10% increments) with a slice thickness of 1 mm. Examination will include left ventricular outflow tract, aortic root, coronary sinus, ascending aorta together with the prosthetic valves. |
|
Jiný: "Sewed-in" valve
Patients who underwent aortic valve replacement with a "sewed-in" aortic valve.
An echocardiogram and a cardiac CT-scan will be conducted.
|
ECG gated CT angiography of the heart will be performed on a 128-slice dual-source and two Stellar detectors CT system with retrospective ECG-gating (Siemens/SOMATOM Definition Flash - Siemens, Germany, 100kV, 395.75 mAs). In details, multi-phase images will be acquired to reconstruct between 10 and 100% of the cardiac cycle (10% increments) with a slice thickness of 1 mm. Examination will include left ventricular outflow tract, aortic root, coronary sinus, ascending aorta together with the prosthetic valves. |
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Časové okno |
|---|---|
|
Comparison of maximum and minimum velocity under patient specific conditions
Časové okno: between 6 months and 4 years after aortic valve replacement
|
between 6 months and 4 years after aortic valve replacement
|
|
Comparison of the effective orifice area under patient specific conditions
Časové okno: between 6 months and 4 years after aortic valve replacement
|
between 6 months and 4 years after aortic valve replacement
|
|
Comparison of the percentage of turbulent flow under patient specific conditions
Časové okno: between 6 months and 4 years after aortic valve replacement
|
between 6 months and 4 years after aortic valve replacement
|
|
Comparison of the pressure drop under patient specific conditions
Časové okno: between 6 months and 4 years after aortic valve replacement
|
between 6 months and 4 years after aortic valve replacement
|
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Patient-specific, computer simulated pressure gradients compared to echocardiographically obtained pressure gradients.
Časové okno: between 6 months and 4 years after aortic valve replacement
|
The first secondary outcome measure is the comparison of -pressure gradients as computed by the model against the same data collected standardly with echocardiographic technique. Differences will be quantified. If positive (< 10%), this assessment would enhance the use of patient-specific models in clinics as a predictive tool for detailed haemodynamics." |
between 6 months and 4 years after aortic valve replacement
|
|
Patient-specific, computer simulated peak velocity compared to echocardiographically obtained peak velocity.
Časové okno: between 6 months and 4 years after aortic valve replacement
|
The second secondary outcome measure is the comparison of -peak velocity as computed by the model against the same data collected standardly with echocardiographic technique. Differences will be quantified. If positive (< 10%), this assessment would enhance the use of patient-specific models in clinics as a predictive tool for detailed haemodynamics." |
between 6 months and 4 years after aortic valve replacement
|
Spolupracovníci a vyšetřovatelé
Sponzor
Spolupracovníci
Vyšetřovatelé
- Vrchní vyšetřovatel: Alfred Kocher, MD, Division of Cardiac Surgery, Department of Surgery, Medical University of Vienna
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia
Primární dokončení (Očekávaný)
Dokončení studie (Očekávaný)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Odhad)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další relevantní podmínky MeSH
Další identifikační čísla studie
- 1790/2013-1
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
produkt vyrobený a vyvážený z USA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .
Klinické studie na Stenóza aortální chlopně
-
InnoRa GmbHDokončeno
-
China National Center for Cardiovascular DiseasesNáborDe Novo Stenosis | Balónek potažený lékem | Stent uvolňující léčivoČína
-
IRCCS Azienda Ospedaliero-Universitaria di BolognaAktivní, ne náborPCI | De Novo Stenosis | DCBItálie
-
Zunyi Medical CollegeDokončenoAkutní koronární syndrom | De Novo StenosisČína
-
Xijing HospitalAktivní, ne náborIschemická choroba srdeční | De Novo StenosisČína
-
Genoss Co., Ltd.DokončenoOnemocnění periferních tepen | De Novo StenosisKorejská republika
-
Xijing HospitalNáborIschemická choroba srdeční | De Novo StenosisČína
-
Xijing HospitalAktivní, ne náborIschemická choroba srdeční | Perkutánní koronární intervence | De Novo StenosisČína
-
Harbin Medical UniversityThe First Affiliated Hospital with Nanjing Medical University; Peking University... a další spolupracovníciDokončenoIschemická choroba srdeční | De Novo Stenosis | Klinická studie | Akutní koronární syndromy | ACS | DCB | Lékem potažený balónekČína
-
Korea University Ansan HospitalB. Braun Korea Co., Ltd.NáborIschemická choroba srdeční | De Novo Stenosis | Aterosklerotický plakKorejská republika
Klinické studie na Cardiac CT-scan
-
University Hospital Plymouth NHS TrustDokončenoKoronární stenózaSpojené království
-
Imperial College LondonDokončenoMetastatický renální buněčný karcinomSpojené království
-
Xijing HospitalAktivní, ne nábor
-
Jules Bordet InstituteDokončenoKolorektální karcinom Metastatický | Hodnocení včasné reakce | Fdg-PETBelgie
-
London Health Sciences CentreDokončeno
-
The First Affiliated Hospital of Xiamen UniversityDokončenoAdenokarcinom plic | PET/CT | 18F-FDG | 68Ga-FAPIČína
-
Qiubai LiZatím nenabírámeRakovina hlavy a krku | Rakovina slinivky | Rakovina slinivky břišníSpojené státy
-
Rambam Health Care CampusDokončenoKlasický Hodgkinův lymfom | Nodulární skleróza | Smíšená celularita | Deplece lymfocytů | Bohaté na lymfocytyIzrael
-
GE HealthcareDokončeno
-
Central Hospital, Nancy, FrancePfizerNeznámýStrukturální sakro-iliitidaFrancie