Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

What Effect Does Intubation Have on Regional Lung Ventilation?

28 czerwca 2018 zaktualizowane przez: The Leeds Teaching Hospitals NHS Trust

Observational Study of the Effect of Tracheal Intubation and Tracheal Tube Position on Regional Lung Ventilation During General Anaesthesia

During any general anaesthetic which involves muscle relaxation artificial breathing is required. This is most commonly provided by pushing air under pressure (positive pressure ventilation) into the lungs via a tube in the airway (the tracheal tube). It has been observed for many years that with this form of breathing the distribution of gas within the lungs differs from that seen during 'natural' breathing: more of the gas goes to the upper parts of the lung than lower parts. This change in how the gas is distributed can lead to problems with how well oxygen is taken up by blood and carbon dioxide removed from the body. Previous work using mathematical modelling has found that the position of the tracheal tube might affect air distribution, but this has previously been difficult to study in 'real life', requiring the use of radioactive dyes and computerised tomography (CT). However a bedside test is now available which allows us to study these changes rapidly and non-invasively, using electrical impedance tomography (EIT). The EIT device is commercially available (PulmoVista®, Draeger UK) and is used in hospitals worldwide as a bedside monitor of lung ventilation.

This study aims to investigate the effect of tracheal intubation on regional ventilation of the lungs by comparing measurements before and after the patient is anaesthetised and intubated. The investgiators aim to show whether altered patterns of ventilation are caused by patients simply being asleep and ventilated, or whether these changes are due to the use of a tracheal tube itself. The exact effect of tube position will also be studied by measuring ventilation as the tube is deliberately advanced until it enters one of the lungs. This will give us information about the ideal position for a tube within the trachea to promote optimal ventilation patterns within the lungs

Przegląd badań

Status

Zakończony

Warunki

Typ studiów

Obserwacyjny

Zapisy (Rzeczywisty)

10

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Lokalizacje studiów

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

16 lat do 100 lat (Dziecko, Dorosły, Starszy dorosły)

Akceptuje zdrowych ochotników

Nie

Płeć kwalifikująca się do nauki

Wszystko

Metoda próbkowania

Próbka bez prawdopodobieństwa

Badana populacja

All patients attending for a surgical procedure are eligible and will be approached.

Opis

Inclusion Criteria:

  1. Willing and able to consent
  2. undergoing a surgical procedure for which the anaesthetic technique includes muscle relaxation, intubation and ventilation for clinical care.

Exclusion Criteria:

  1. Unwilling or unable to consent
  2. co-existant respiratory disease associated with known abnormalities of ventilation/perfusion matching. This includes chronic obstructive pulmonary disease, asthma, or abnormalities of the chest wall or abdomen affecting ventilation e.g. morbid obesity
  3. Requirement for double-lumen tracheal tube for clinical care
  4. increased risk of regurgitation/aspiration e.g. pregnancy, symptomatic acid reflux, structural abnormalities of the gastro-intestinal tract (e.g. hiatus hernia)

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Manipulation of the tracheal tube and deliberate insertion into a right or left main bronchus
Ramy czasowe: 20 mins
General anaesthesia will then be induced, and when the participant is asleep a further set of measurements will be taken using the Electrical impedance tomography (EIT) belt whilst ventilation is maintained using the normal bag-mask ventilation technique used by anaesthetists in the first few minutes of the anaesthetic. Following this, the trachea will be intubated by the anaesthetist clinically responsible for the patient, and a further set of EIT measurements taken.
20 mins

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Rzeczywisty)

20 października 2017

Zakończenie podstawowe (Rzeczywisty)

31 marca 2018

Ukończenie studiów (Rzeczywisty)

31 marca 2018

Daty rejestracji na studia

Pierwszy przesłany

19 października 2017

Pierwszy przesłany, który spełnia kryteria kontroli jakości

23 października 2017

Pierwszy wysłany (Rzeczywisty)

24 października 2017

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

2 lipca 2018

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

28 czerwca 2018

Ostatnia weryfikacja

1 czerwca 2018

Więcej informacji

Terminy związane z tym badaniem

Inne numery identyfikacyjne badania

  • AN17/97842

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Subskrybuj