What Effect Does Intubation Have on Regional Lung Ventilation?
Observational Study of the Effect of Tracheal Intubation and Tracheal Tube Position on Regional Lung Ventilation During General Anaesthesia
During any general anaesthetic which involves muscle relaxation artificial breathing is required. This is most commonly provided by pushing air under pressure (positive pressure ventilation) into the lungs via a tube in the airway (the tracheal tube). It has been observed for many years that with this form of breathing the distribution of gas within the lungs differs from that seen during 'natural' breathing: more of the gas goes to the upper parts of the lung than lower parts. This change in how the gas is distributed can lead to problems with how well oxygen is taken up by blood and carbon dioxide removed from the body. Previous work using mathematical modelling has found that the position of the tracheal tube might affect air distribution, but this has previously been difficult to study in 'real life', requiring the use of radioactive dyes and computerised tomography (CT). However a bedside test is now available which allows us to study these changes rapidly and non-invasively, using electrical impedance tomography (EIT). The EIT device is commercially available (PulmoVista®, Draeger UK) and is used in hospitals worldwide as a bedside monitor of lung ventilation.
This study aims to investigate the effect of tracheal intubation on regional ventilation of the lungs by comparing measurements before and after the patient is anaesthetised and intubated. The investgiators aim to show whether altered patterns of ventilation are caused by patients simply being asleep and ventilated, or whether these changes are due to the use of a tracheal tube itself. The exact effect of tube position will also be studied by measuring ventilation as the tube is deliberately advanced until it enters one of the lungs. This will give us information about the ideal position for a tube within the trachea to promote optimal ventilation patterns within the lungs
Panoramica dello studio
Stato
Condizioni
Tipo di studio
Iscrizione (Effettivo)
Contatti e Sedi
Luoghi di studio
-
-
-
Leeds, Regno Unito, LS1 3HE,
- Leeds Teaching Hospitals NHS Trust
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Descrizione
Inclusion Criteria:
- Willing and able to consent
- undergoing a surgical procedure for which the anaesthetic technique includes muscle relaxation, intubation and ventilation for clinical care.
Exclusion Criteria:
- Unwilling or unable to consent
- co-existant respiratory disease associated with known abnormalities of ventilation/perfusion matching. This includes chronic obstructive pulmonary disease, asthma, or abnormalities of the chest wall or abdomen affecting ventilation e.g. morbid obesity
- Requirement for double-lumen tracheal tube for clinical care
- increased risk of regurgitation/aspiration e.g. pregnancy, symptomatic acid reflux, structural abnormalities of the gastro-intestinal tract (e.g. hiatus hernia)
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Manipulation of the tracheal tube and deliberate insertion into a right or left main bronchus
Lasso di tempo: 20 mins
|
General anaesthesia will then be induced, and when the participant is asleep a further set of measurements will be taken using the Electrical impedance tomography (EIT) belt whilst ventilation is maintained using the normal bag-mask ventilation technique used by anaesthetists in the first few minutes of the anaesthetic.
Following this, the trachea will be intubated by the anaesthetist clinically responsible for the patient, and a further set of EIT measurements taken.
|
20 mins
|
Collaboratori e investigatori
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Altri numeri di identificazione dello studio
- AN17/97842
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .