Introduction: Dynamic and static compliance should be calculated as a routine part of ventilator monitoring. Dynamic and static compliance are 60-100 mL/cm H2O. A decrease in dynamic compliance without a change in the static compliance suggests an acute increase in airway resistance and can be assessed further by comparing peak pressure and plateau pressure. The normal gradient is approximately 10 cm H2O. A gradient >10 cm H2O may be secondary to endotracheal tube obstruction, mucous plugging, or bronchospasm. If volume is constant, acute changes in both dynamic and static compliance suggest a decrease in respiratory system compliance that may be caused by worsening increasing abdominal pressures. When static compliance is <25 mL/cm H2O, ventilator weaning may be difficult secondary to tachypnea during spontaneous breathing trials. (1) Aim of the work: to detect the cardiopulmonary burden of surgical ring retractors application during abdominal surgeries in supine versus lateral position (cancer bladder for supine position and open surgical nephrectomy for lateral position). Hypothesis: Abdominal retractors application would produce more cardiopulmonary instability during lateral position than during supine position for abdominal surgery. Patient & Methods: This comparative prospective randomized study, will be done on ASA I-II patients, both sexes, Age 18 - 65 year, to compare pulmonary compliance and cardiac performance before, during and after surgical self-retaining abdominal retractors application patients will be divided into 2 groups; 1st group (S) will undergo orthotropic cancer bladder diversion and the 2nd group (L) both supine and lateral position for open surgical nephrectomy for lateral position.

Przegląd badań

Status

Zakończony

Interwencja / Leczenie

Szczegółowy opis

Introduction: Dynamic and static compliance should be calculated as a routine part of ventilator monitoring. Dynamic and static compliance are 60-100 mL/cm H2O. A decrease in dynamic compliance without a change in the static compliance suggests an acute increase in airway resistance and can be assessed further by comparing peak pressure and plateau pressure. The normal gradient is approximately 10 cm H2O. A gradient >10 cm H2O may be secondary to endotracheal tube obstruction, mucous plugging, or bronchospasm. If volume is constant, acute changes in both dynamic and static compliance suggest a decrease in respiratory system compliance that may be caused by worsening increasing abdominal pressures. When static compliance is <25 mL/cm H2O, ventilator weaning may be difficult secondary to tachypnea during spontaneous breathing trials. (1) Aim of the work: to detect the cardiopulmonary burden of surgical ring retractors application during abdominal surgeries in supine versus lateral position (cancer bladder for supine position and open surgical nephrectomy for lateral position). Hypothesis: Abdominal retractors application would produce more cardiopulmonary instability during lateral position than during supine position for abdominal surgery. Patient & Methods: This comparative prospective randomized study, will be done on ASA I-II patients, both sexes, Age 18 - 65 year, to compare pulmonary compliance and cardiac performance before, during and after surgical self-retaining abdominal retractors application patients will be divided into 2 groups; 1st group (S) will undergo orthotropic cancer bladder diversion and the 2nd group (L) both supine and lateral position for open surgical nephrectomy for lateral position. Study will be done at Mansoura University Hospital, during the year 2018, for 4 month duration, starting predected date=1-11-2018 actual study start date=15-12-2018[ NB. by mistake in the 1st registration i have regestered the study protocol predicted time of study start but actually the study started on 15-12-2018 thats why i changed the date more than one time ] till 30-3-2019 after approval of IRB (Institutional Review Board), Mansoura Faculty of Medicine. Primary outcome; composite 1ry outcome [1-Dynamic pulmonary compliance.2- Cardiac Index] during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups. Secondary outcome: Static lung compliance, Cardiac output, Stroke volume SV - stroke volume variability (SVV)-Cardiac performance index CPI, O2 delivery DIO2. Noninvasive Intraoperative hemodynamic (MBP, HR, O2 saturation)] during and after surgical ring retractor application compared to the same variable reading prior retractor application and in between both groups.

Typ studiów

Obserwacyjny

Zapisy (Rzeczywisty)

40

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Lokalizacje studiów

    • Dakahlia
      • Mansourah, Dakahlia, Egipt, 35511
        • Mansoura faculty of Medicine- Mansoura Urology and nephrology center

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

18 lat do 65 lat (Dorosły, Starszy dorosły)

Akceptuje zdrowych ochotników

Nie

Płeć kwalifikująca się do nauki

Wszystko

Metoda próbkowania

Próbka prawdopodobieństwa

Badana populacja

-Patients admitted to the Urology Department, Mansoura Urology and Nephrology center, Faculty of medicine Mansoura University .

Opis

Inclusion Criteria:

  • ASA I-II patients
  • both sexes
  • Age 18 - 65 year
  • surgical time ≥ 6hours for Orthotopic urinary bladder diversion surgery for cancer bladder patients and 3 hours for open surgical nephrectomy.

Exclusion Criteria:

  • Body mass index (BMI) greater than 35 kg. m-2.
  • Asthma requiring bronchodilator therapy.
  • Chronic Obstructive Pulmonary Disease, GOLD classification III and IV.
  • Severe pulmonary disease.
  • Hemodynamic instability (hypotension or tachycardia).
  • History of congestive heart failure or New York Heart Association (NYHA) functional class IV
  • Right ventricular dysfunction.
  • Severe valvular heart disease.
  • Intra-cardiac shunts.
  • Intracranial hypertension.
  • Cardiac rhythm other than regular sinus.
  • Severe chronic kidney disease (glomerular filtration rate < 30 ml. min-1. 1.73 m2).
  • Liver cirrhosis (Child Pugh class B or C).
  • Pregnancy.
  • Previous thoracic surgery (lobectomy, bilobectomy, or pneumonectomy).
  • Lung metastatic surgery.
  • Previous receiving chemotherapy.
  • Emergency surgery.
  • Preoperative need for invasive mechanical ventilation.

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

Kohorty i interwencje

Grupa / Kohorta
Interwencja / Leczenie
supine position group= Group (S)
1st group of 20 patients will undergo urinary bladder cystectomy and orthotopic urinary diversion lying supine with ring abdominal retractors
Primary outcome; composite 1ry outcome [1-Dynamic pulmonary compliance monitoring.2- Cardiac Index monitoring] during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups. Secondary outcome: Static lung compliance, Cardiac output, Stroke volume SV - stroke volume variability (SVV)-Cardiac performance index, O2 delivery DIO2. Noninvasive Intraoperative hemodynamic (MBP, HR, O2 saturation)] during and after surgical ring retractor application compared to the same variable reading prior retractor application and in between both groups.
lateral position group = Group (L)
2nd group of 20 patients will undergo surgical open nephrectomy lying lateral position with self retaining abdominal retractors
Primary outcome; composite 1ry outcome [1-Dynamic pulmonary compliance monitoring.2- Cardiac Index monitoring] during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups. Secondary outcome: Static lung compliance, Cardiac output, Stroke volume SV - stroke volume variability (SVV)-Cardiac performance index, O2 delivery DIO2. Noninvasive Intraoperative hemodynamic (MBP, HR, O2 saturation)] during and after surgical ring retractor application compared to the same variable reading prior retractor application and in between both groups.

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
-non invasive Dynamic pulmonary compliance .
Ramy czasowe: mean dynamic compliance at minutes 30,60,90,120,180,210 240 post retractor application compared to mean dynamic compliance at minutes 10,20,30,post endotracheal intubation(Basal Value preretractor application)
dynamic pulmonary compliance during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
mean dynamic compliance at minutes 30,60,90,120,180,210 240 post retractor application compared to mean dynamic compliance at minutes 10,20,30,post endotracheal intubation(Basal Value preretractor application)
Non invasive Cardiac Index
Ramy czasowe: mean Non invasive Cardiac Index at minutes 30,60,90,120,180,210 240 post retractor application compared to mean Non invasive Cardiac Index at minutes 10,20,30,post endotracheal intubation(Basal Value preretractor application)
Cardiac index monitoring during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
mean Non invasive Cardiac Index at minutes 30,60,90,120,180,210 240 post retractor application compared to mean Non invasive Cardiac Index at minutes 10,20,30,post endotracheal intubation(Basal Value preretractor application)

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Static lung compliance
Ramy czasowe: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
Static lung compliance during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
Cardiac output.
Ramy czasowe: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
Cardiac output. during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
Stroke volume SV
Ramy czasowe: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
Stroke volume SV. during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
- stroke volume variability (SVV)
Ramy czasowe: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
Stroke volume variability (SVV)during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
-Cardiac performance index CPI
Ramy czasowe: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
Cardiac performance index during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
Oxygen delivery DIO2
Ramy czasowe: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
Oxygen delivery DIO2 during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
. Noninvasive Intraoperative MBP
Ramy czasowe: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
Noninvasive Intraoperative MBP during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
HR
Ramy czasowe: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
HR during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
arterial O2 saturation(SaO2%)
Ramy czasowe: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
SaO2 saturation during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
End tidal Co2 EtCO2
Ramy czasowe: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
End tidal Co2 EtCO2 during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Śledczy

  • Główny śledczy: Mohamed A. Ghanem, A professor, Mansoura Univeristy

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Rzeczywisty)

15 grudnia 2018

Zakończenie podstawowe (Rzeczywisty)

30 marca 2019

Ukończenie studiów (Rzeczywisty)

30 marca 2019

Daty rejestracji na studia

Pierwszy przesłany

9 grudnia 2018

Pierwszy przesłany, który spełnia kryteria kontroli jakości

12 grudnia 2018

Pierwszy wysłany (Rzeczywisty)

14 grudnia 2018

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

20 czerwca 2019

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

18 czerwca 2019

Ostatnia weryfikacja

1 czerwca 2019

Więcej informacji

Terminy związane z tym badaniem

Inne numery identyfikacyjne badania

  • R.18.11.337

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .