- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT03776292
Cardiopulmonary Changes Prolonged Surgical Abdominal Retractors Application in Supine Versus Lateral Position
18 de junio de 2019 actualizado por: Mohamed Abd Latif Ghanim, Mansoura University
Cardiopulmonary Effects of Prolonged Surgical Abdominal Retractors Application in Supine Versus Lateral Position During General Anesthesia
Introduction: Dynamic and static compliance should be calculated as a routine part of ventilator monitoring.
Dynamic and static compliance are 60-100 mL/cm H2O.
A decrease in dynamic compliance without a change in the static compliance suggests an acute increase in airway resistance and can be assessed further by comparing peak pressure and plateau pressure.
The normal gradient is approximately 10 cm H2O.
A gradient >10 cm H2O may be secondary to endotracheal tube obstruction, mucous plugging, or bronchospasm.
If volume is constant, acute changes in both dynamic and static compliance suggest a decrease in respiratory system compliance that may be caused by worsening increasing abdominal pressures.
When static compliance is <25 mL/cm H2O, ventilator weaning may be difficult secondary to tachypnea during spontaneous breathing trials.
(1) Aim of the work: to detect the cardiopulmonary burden of surgical ring retractors application during abdominal surgeries in supine versus lateral position (cancer bladder for supine position and open surgical nephrectomy for lateral position).
Hypothesis: Abdominal retractors application would produce more cardiopulmonary instability during lateral position than during supine position for abdominal surgery.
Patient & Methods: This comparative prospective randomized study, will be done on ASA I-II patients, both sexes, Age 18 - 65 year, to compare pulmonary compliance and cardiac performance before, during and after surgical self-retaining abdominal retractors application patients will be divided into 2 groups; 1st group (S) will undergo orthotropic cancer bladder diversion and the 2nd group (L) both supine and lateral position for open surgical nephrectomy for lateral position.
Descripción general del estudio
Descripción detallada
Introduction: Dynamic and static compliance should be calculated as a routine part of ventilator monitoring.
Dynamic and static compliance are 60-100 mL/cm H2O.
A decrease in dynamic compliance without a change in the static compliance suggests an acute increase in airway resistance and can be assessed further by comparing peak pressure and plateau pressure.
The normal gradient is approximately 10 cm H2O.
A gradient >10 cm H2O may be secondary to endotracheal tube obstruction, mucous plugging, or bronchospasm.
If volume is constant, acute changes in both dynamic and static compliance suggest a decrease in respiratory system compliance that may be caused by worsening increasing abdominal pressures.
When static compliance is <25 mL/cm H2O, ventilator weaning may be difficult secondary to tachypnea during spontaneous breathing trials.
(1) Aim of the work: to detect the cardiopulmonary burden of surgical ring retractors application during abdominal surgeries in supine versus lateral position (cancer bladder for supine position and open surgical nephrectomy for lateral position).
Hypothesis: Abdominal retractors application would produce more cardiopulmonary instability during lateral position than during supine position for abdominal surgery.
Patient & Methods: This comparative prospective randomized study, will be done on ASA I-II patients, both sexes, Age 18 - 65 year, to compare pulmonary compliance and cardiac performance before, during and after surgical self-retaining abdominal retractors application patients will be divided into 2 groups; 1st group (S) will undergo orthotropic cancer bladder diversion and the 2nd group (L) both supine and lateral position for open surgical nephrectomy for lateral position.
Study will be done at Mansoura University Hospital, during the year 2018, for 4 month duration, starting predected date=1-11-2018 actual study start date=15-12-2018[ NB. by mistake in the 1st registration i have regestered the study protocol predicted time of study start but actually the study started on 15-12-2018 thats why i changed the date more than one time ] till 30-3-2019 after approval of IRB (Institutional Review Board), Mansoura Faculty of Medicine.
Primary outcome; composite 1ry outcome [1-Dynamic pulmonary compliance.2-
Cardiac Index] during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups.
Secondary outcome: Static lung compliance, Cardiac output, Stroke volume SV - stroke volume variability (SVV)-Cardiac performance index CPI, O2 delivery DIO2.
Noninvasive Intraoperative hemodynamic (MBP, HR, O2 saturation)] during and after surgical ring retractor application compared to the same variable reading prior retractor application and in between both groups.
Tipo de estudio
De observación
Inscripción (Actual)
40
Contactos y Ubicaciones
Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.
Ubicaciones de estudio
-
-
Dakahlia
-
Mansourah, Dakahlia, Egipto, 35511
- Mansoura faculty of Medicine- Mansoura Urology and nephrology center
-
-
Criterios de participación
Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.
Criterio de elegibilidad
Edades elegibles para estudiar
18 años a 65 años (Adulto, Adulto Mayor)
Acepta Voluntarios Saludables
No
Géneros elegibles para el estudio
Todos
Método de muestreo
Muestra de probabilidad
Población de estudio
-Patients admitted to the Urology Department, Mansoura Urology and Nephrology center, Faculty of medicine Mansoura University .
Descripción
Inclusion Criteria:
- ASA I-II patients
- both sexes
- Age 18 - 65 year
- surgical time ≥ 6hours for Orthotopic urinary bladder diversion surgery for cancer bladder patients and 3 hours for open surgical nephrectomy.
Exclusion Criteria:
- Body mass index (BMI) greater than 35 kg. m-2.
- Asthma requiring bronchodilator therapy.
- Chronic Obstructive Pulmonary Disease, GOLD classification III and IV.
- Severe pulmonary disease.
- Hemodynamic instability (hypotension or tachycardia).
- History of congestive heart failure or New York Heart Association (NYHA) functional class IV
- Right ventricular dysfunction.
- Severe valvular heart disease.
- Intra-cardiac shunts.
- Intracranial hypertension.
- Cardiac rhythm other than regular sinus.
- Severe chronic kidney disease (glomerular filtration rate < 30 ml. min-1. 1.73 m2).
- Liver cirrhosis (Child Pugh class B or C).
- Pregnancy.
- Previous thoracic surgery (lobectomy, bilobectomy, or pneumonectomy).
- Lung metastatic surgery.
- Previous receiving chemotherapy.
- Emergency surgery.
- Preoperative need for invasive mechanical ventilation.
Plan de estudios
Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.
¿Cómo está diseñado el estudio?
Detalles de diseño
Cohortes e Intervenciones
Grupo / Cohorte |
Intervención / Tratamiento |
|---|---|
|
supine position group= Group (S)
1st group of 20 patients will undergo urinary bladder cystectomy and orthotopic urinary diversion lying supine with ring abdominal retractors
|
Primary outcome; composite 1ry outcome [1-Dynamic pulmonary compliance monitoring.2-
Cardiac Index monitoring] during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups.
Secondary outcome: Static lung compliance, Cardiac output, Stroke volume SV - stroke volume variability (SVV)-Cardiac performance index, O2 delivery DIO2.
Noninvasive Intraoperative hemodynamic (MBP, HR, O2 saturation)] during and after surgical ring retractor application compared to the same variable reading prior retractor application and in between both groups.
|
|
lateral position group = Group (L)
2nd group of 20 patients will undergo surgical open nephrectomy lying lateral position with self retaining abdominal retractors
|
Primary outcome; composite 1ry outcome [1-Dynamic pulmonary compliance monitoring.2-
Cardiac Index monitoring] during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups.
Secondary outcome: Static lung compliance, Cardiac output, Stroke volume SV - stroke volume variability (SVV)-Cardiac performance index, O2 delivery DIO2.
Noninvasive Intraoperative hemodynamic (MBP, HR, O2 saturation)] during and after surgical ring retractor application compared to the same variable reading prior retractor application and in between both groups.
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
-non invasive Dynamic pulmonary compliance .
Periodo de tiempo: mean dynamic compliance at minutes 30,60,90,120,180,210 240 post retractor application compared to mean dynamic compliance at minutes 10,20,30,post endotracheal intubation(Basal Value preretractor application)
|
dynamic pulmonary compliance during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
|
mean dynamic compliance at minutes 30,60,90,120,180,210 240 post retractor application compared to mean dynamic compliance at minutes 10,20,30,post endotracheal intubation(Basal Value preretractor application)
|
|
Non invasive Cardiac Index
Periodo de tiempo: mean Non invasive Cardiac Index at minutes 30,60,90,120,180,210 240 post retractor application compared to mean Non invasive Cardiac Index at minutes 10,20,30,post endotracheal intubation(Basal Value preretractor application)
|
Cardiac index monitoring during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
|
mean Non invasive Cardiac Index at minutes 30,60,90,120,180,210 240 post retractor application compared to mean Non invasive Cardiac Index at minutes 10,20,30,post endotracheal intubation(Basal Value preretractor application)
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Static lung compliance
Periodo de tiempo: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
|
Static lung compliance during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
|
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
|
|
Cardiac output.
Periodo de tiempo: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
|
Cardiac output.
during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
|
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
|
|
Stroke volume SV
Periodo de tiempo: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
|
Stroke volume SV. during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
|
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
|
|
- stroke volume variability (SVV)
Periodo de tiempo: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
|
Stroke volume variability (SVV)during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
|
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
|
|
-Cardiac performance index CPI
Periodo de tiempo: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
|
Cardiac performance index during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
|
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
|
|
Oxygen delivery DIO2
Periodo de tiempo: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
|
Oxygen delivery DIO2 during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
|
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
|
|
. Noninvasive Intraoperative MBP
Periodo de tiempo: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
|
Noninvasive Intraoperative MBP during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
|
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
|
|
HR
Periodo de tiempo: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
|
HR during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
|
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
|
|
arterial O2 saturation(SaO2%)
Periodo de tiempo: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
|
SaO2 saturation during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
|
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
|
|
End tidal Co2 EtCO2
Periodo de tiempo: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
|
End tidal Co2 EtCO2 during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
|
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
|
Colaboradores e Investigadores
Aquí es donde encontrará personas y organizaciones involucradas en este estudio.
Patrocinador
Investigadores
- Investigador principal: Mohamed A. Ghanem, A professor, Mansoura Univeristy
Fechas de registro del estudio
Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.
Fechas importantes del estudio
Inicio del estudio (Actual)
15 de diciembre de 2018
Finalización primaria (Actual)
30 de marzo de 2019
Finalización del estudio (Actual)
30 de marzo de 2019
Fechas de registro del estudio
Enviado por primera vez
9 de diciembre de 2018
Primero enviado que cumplió con los criterios de control de calidad
12 de diciembre de 2018
Publicado por primera vez (Actual)
14 de diciembre de 2018
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
20 de junio de 2019
Última actualización enviada que cumplió con los criterios de control de calidad
18 de junio de 2019
Última verificación
1 de junio de 2019
Más información
Términos relacionados con este estudio
Palabras clave
Otros números de identificación del estudio
- R.18.11.337
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
No
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
No
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .