Introduction: Dynamic and static compliance should be calculated as a routine part of ventilator monitoring. Dynamic and static compliance are 60-100 mL/cm H2O. A decrease in dynamic compliance without a change in the static compliance suggests an acute increase in airway resistance and can be assessed further by comparing peak pressure and plateau pressure. The normal gradient is approximately 10 cm H2O. A gradient >10 cm H2O may be secondary to endotracheal tube obstruction, mucous plugging, or bronchospasm. If volume is constant, acute changes in both dynamic and static compliance suggest a decrease in respiratory system compliance that may be caused by worsening increasing abdominal pressures. When static compliance is <25 mL/cm H2O, ventilator weaning may be difficult secondary to tachypnea during spontaneous breathing trials. (1) Aim of the work: to detect the cardiopulmonary burden of surgical ring retractors application during abdominal surgeries in supine versus lateral position (cancer bladder for supine position and open surgical nephrectomy for lateral position). Hypothesis: Abdominal retractors application would produce more cardiopulmonary instability during lateral position than during supine position for abdominal surgery. Patient & Methods: This comparative prospective randomized study, will be done on ASA I-II patients, both sexes, Age 18 - 65 year, to compare pulmonary compliance and cardiac performance before, during and after surgical self-retaining abdominal retractors application patients will be divided into 2 groups; 1st group (S) will undergo orthotropic cancer bladder diversion and the 2nd group (L) both supine and lateral position for open surgical nephrectomy for lateral position.

Visão geral do estudo

Status

Concluído

Condições

Intervenção / Tratamento

Descrição detalhada

Introduction: Dynamic and static compliance should be calculated as a routine part of ventilator monitoring. Dynamic and static compliance are 60-100 mL/cm H2O. A decrease in dynamic compliance without a change in the static compliance suggests an acute increase in airway resistance and can be assessed further by comparing peak pressure and plateau pressure. The normal gradient is approximately 10 cm H2O. A gradient >10 cm H2O may be secondary to endotracheal tube obstruction, mucous plugging, or bronchospasm. If volume is constant, acute changes in both dynamic and static compliance suggest a decrease in respiratory system compliance that may be caused by worsening increasing abdominal pressures. When static compliance is <25 mL/cm H2O, ventilator weaning may be difficult secondary to tachypnea during spontaneous breathing trials. (1) Aim of the work: to detect the cardiopulmonary burden of surgical ring retractors application during abdominal surgeries in supine versus lateral position (cancer bladder for supine position and open surgical nephrectomy for lateral position). Hypothesis: Abdominal retractors application would produce more cardiopulmonary instability during lateral position than during supine position for abdominal surgery. Patient & Methods: This comparative prospective randomized study, will be done on ASA I-II patients, both sexes, Age 18 - 65 year, to compare pulmonary compliance and cardiac performance before, during and after surgical self-retaining abdominal retractors application patients will be divided into 2 groups; 1st group (S) will undergo orthotropic cancer bladder diversion and the 2nd group (L) both supine and lateral position for open surgical nephrectomy for lateral position. Study will be done at Mansoura University Hospital, during the year 2018, for 4 month duration, starting predected date=1-11-2018 actual study start date=15-12-2018[ NB. by mistake in the 1st registration i have regestered the study protocol predicted time of study start but actually the study started on 15-12-2018 thats why i changed the date more than one time ] till 30-3-2019 after approval of IRB (Institutional Review Board), Mansoura Faculty of Medicine. Primary outcome; composite 1ry outcome [1-Dynamic pulmonary compliance.2- Cardiac Index] during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups. Secondary outcome: Static lung compliance, Cardiac output, Stroke volume SV - stroke volume variability (SVV)-Cardiac performance index CPI, O2 delivery DIO2. Noninvasive Intraoperative hemodynamic (MBP, HR, O2 saturation)] during and after surgical ring retractor application compared to the same variable reading prior retractor application and in between both groups.

Tipo de estudo

Observacional

Inscrição (Real)

40

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

    • Dakahlia
      • Mansourah, Dakahlia, Egito, 35511
        • Mansoura faculty of Medicine- Mansoura Urology and nephrology center

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

18 anos a 65 anos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Tudo

Método de amostragem

Amostra de Probabilidade

População do estudo

-Patients admitted to the Urology Department, Mansoura Urology and Nephrology center, Faculty of medicine Mansoura University .

Descrição

Inclusion Criteria:

  • ASA I-II patients
  • both sexes
  • Age 18 - 65 year
  • surgical time ≥ 6hours for Orthotopic urinary bladder diversion surgery for cancer bladder patients and 3 hours for open surgical nephrectomy.

Exclusion Criteria:

  • Body mass index (BMI) greater than 35 kg. m-2.
  • Asthma requiring bronchodilator therapy.
  • Chronic Obstructive Pulmonary Disease, GOLD classification III and IV.
  • Severe pulmonary disease.
  • Hemodynamic instability (hypotension or tachycardia).
  • History of congestive heart failure or New York Heart Association (NYHA) functional class IV
  • Right ventricular dysfunction.
  • Severe valvular heart disease.
  • Intra-cardiac shunts.
  • Intracranial hypertension.
  • Cardiac rhythm other than regular sinus.
  • Severe chronic kidney disease (glomerular filtration rate < 30 ml. min-1. 1.73 m2).
  • Liver cirrhosis (Child Pugh class B or C).
  • Pregnancy.
  • Previous thoracic surgery (lobectomy, bilobectomy, or pneumonectomy).
  • Lung metastatic surgery.
  • Previous receiving chemotherapy.
  • Emergency surgery.
  • Preoperative need for invasive mechanical ventilation.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

Coortes e Intervenções

Grupo / Coorte
Intervenção / Tratamento
supine position group= Group (S)
1st group of 20 patients will undergo urinary bladder cystectomy and orthotopic urinary diversion lying supine with ring abdominal retractors
Primary outcome; composite 1ry outcome [1-Dynamic pulmonary compliance monitoring.2- Cardiac Index monitoring] during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups. Secondary outcome: Static lung compliance, Cardiac output, Stroke volume SV - stroke volume variability (SVV)-Cardiac performance index, O2 delivery DIO2. Noninvasive Intraoperative hemodynamic (MBP, HR, O2 saturation)] during and after surgical ring retractor application compared to the same variable reading prior retractor application and in between both groups.
lateral position group = Group (L)
2nd group of 20 patients will undergo surgical open nephrectomy lying lateral position with self retaining abdominal retractors
Primary outcome; composite 1ry outcome [1-Dynamic pulmonary compliance monitoring.2- Cardiac Index monitoring] during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups. Secondary outcome: Static lung compliance, Cardiac output, Stroke volume SV - stroke volume variability (SVV)-Cardiac performance index, O2 delivery DIO2. Noninvasive Intraoperative hemodynamic (MBP, HR, O2 saturation)] during and after surgical ring retractor application compared to the same variable reading prior retractor application and in between both groups.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
-non invasive Dynamic pulmonary compliance .
Prazo: mean dynamic compliance at minutes 30,60,90,120,180,210 240 post retractor application compared to mean dynamic compliance at minutes 10,20,30,post endotracheal intubation(Basal Value preretractor application)
dynamic pulmonary compliance during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
mean dynamic compliance at minutes 30,60,90,120,180,210 240 post retractor application compared to mean dynamic compliance at minutes 10,20,30,post endotracheal intubation(Basal Value preretractor application)
Non invasive Cardiac Index
Prazo: mean Non invasive Cardiac Index at minutes 30,60,90,120,180,210 240 post retractor application compared to mean Non invasive Cardiac Index at minutes 10,20,30,post endotracheal intubation(Basal Value preretractor application)
Cardiac index monitoring during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
mean Non invasive Cardiac Index at minutes 30,60,90,120,180,210 240 post retractor application compared to mean Non invasive Cardiac Index at minutes 10,20,30,post endotracheal intubation(Basal Value preretractor application)

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Static lung compliance
Prazo: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
Static lung compliance during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
Cardiac output.
Prazo: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
Cardiac output. during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
Stroke volume SV
Prazo: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
Stroke volume SV. during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
- stroke volume variability (SVV)
Prazo: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
Stroke volume variability (SVV)during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
-Cardiac performance index CPI
Prazo: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
Cardiac performance index during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
Oxygen delivery DIO2
Prazo: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
Oxygen delivery DIO2 during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
. Noninvasive Intraoperative MBP
Prazo: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
Noninvasive Intraoperative MBP during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
HR
Prazo: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
HR during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
arterial O2 saturation(SaO2%)
Prazo: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
SaO2 saturation during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
End tidal Co2 EtCO2
Prazo: After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes
End tidal Co2 EtCO2 during and after surgical retractor application compared to the same variables reading prior retractor application and in between both groups
After endotracheal intubation recorded 3 times every 10 minutes -After Abdominal retractors application recorded every 30 minutes for 6 readings -After retractor removal 3 times every 10 minutes

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Investigadores

  • Investigador principal: Mohamed A. Ghanem, A professor, Mansoura Univeristy

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

15 de dezembro de 2018

Conclusão Primária (Real)

30 de março de 2019

Conclusão do estudo (Real)

30 de março de 2019

Datas de inscrição no estudo

Enviado pela primeira vez

9 de dezembro de 2018

Enviado pela primeira vez que atendeu aos critérios de CQ

12 de dezembro de 2018

Primeira postagem (Real)

14 de dezembro de 2018

Atualizações de registro de estudo

Última Atualização Postada (Real)

20 de junho de 2019

Última atualização enviada que atendeu aos critérios de controle de qualidade

18 de junho de 2019

Última verificação

1 de junho de 2019

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • R.18.11.337

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever