Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

Plasma Transthyretin Levels and Risk of Type 2 Diabetes Mellitus and Impaired Glucose Regulation

7 maja 2022 zaktualizowane przez: Liegang Liu

Plasma Transthyretin Levels and Risk of Type 2 Diabetes Mellitus and Impaired Glucose Regulation in a Chinese Population

Objective: To investigate the association between plasma transthyretin levels and risk of newly diagnosed type 2 diabetes mellitus (T2DM) and impaired glucose regulation (IGR) in a Chinese population.

Design: We performed a case-control study, including 1,244 newly diagnosed T2DM patients, 837 newly diagnosed IGR patients, and 1,244 individuals with normal glucose tolerance (NGT). The diagnostic criteria were recommended by World Health Organization in 1999. All cases were recruited from patients who, for the first time, received a diagnosis of T2DM in the Department of Endocrinology, Tongji Hospital, Tongji Medical College, Wuhan, China, from December 2010 to December 2016. Concomitantly, general population undergoing a routine health checkup in the same hospital were enrolled as controls. The inclusion criteria were age ≥ 30 years, BMI < 40 kg/m2, and no history of diagnosis of diabetes or receiving pharmacological treatment for hypertension and hyperlipidemia. Participants with clinically significant neurological, endocrinological, psychological or other systemic diseases, as well as acute illness or chronic inflammatory or infectious diseases, were excluded from the present study. Written informed consent was obtained from each participant. Besides, cases were stringently matched to controls in a 1:1 ratio, based on sex and age (± 3 years). All participants enrolled were of Han ethnicity, and gave a commitment of taking no medication known affecting glucose tolerance or insulin secretion before participating in the study. Fasting blood samples were collected in EDTA-anticoagulative tubes and separated for plasma within 1 h. Then plasma was kept at -80℃ prior to analyses. Plasma transthyretin levels were measured by BS 200 Autoanalyser (Mindray, Shenzhen, China) using immunoturbidimetric method.

Przegląd badań

Typ studiów

Obserwacyjny

Zapisy (Rzeczywisty)

3325

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

24 lata do 82 lata (Dorosły, Starszy dorosły)

Akceptuje zdrowych ochotników

Tak

Płeć kwalifikująca się do nauki

Wszystko

Metoda próbkowania

Próbka prawdopodobieństwa

Badana populacja

All the participants enrolled were of Chinese Han ethnicity. They gave informed written consent to the study and did not take any medication known to affect glucose tolerance or insulin secretion before participation.

Opis

Inclusion Criteria:

  • Age ≥ 30 years, BMI < 40 kg/m2, and no history of diagnosis of diabetes or receiving pharmacological treatment for hypertension and hyperlipidemia

Exclusion Criteria:

  • Clinically significant neurological, endocrinological, psychological or other systemic diseases, as well as acute illness or chronic inflammatory or infectious diseases.

Incomplete basic information.

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

Kohorty i interwencje

Grupa / Kohorta
Interwencja / Leczenie
Type 2 diabetes mellitus
In this case-control study, T2DM was diagnosed according to the diagnostic criteria recommended by the WHO in 1999. T2DM was confirmed when fasting plasma glucose (FPG) ≥ 7.0 mmol/L and/or 2-h post-glucose load (OGTT2h) ≥ 11.1 mmol/L.
Plasma transthyretin concentrations were measured by BS 200 Autoanalyser (Mindray, Shenzhen, China) using immunoturbidimetric method.
Impaired glucose regulation
In this case-control study, IGR was diagnosed according to the diagnostic criteria recommended by the WHO in 1999. IGR was defined as impaired fasting glucose ([FPG] ≥ 6.1 mmol/L and < 7.0 mmol/L, and [OGTT2h] < 7.8 mmol/L) and/or impaired glucose tolerance (FPG < 7.0 mmol/L, and OGTT2h ≥ 7.8 mmol/L and < 11.1 mmol/L).
Plasma transthyretin concentrations were measured by BS 200 Autoanalyser (Mindray, Shenzhen, China) using immunoturbidimetric method.
Control
Those with FPG < 6.1 mmol/L and OGTT2h < 7.8 mmol/L were considered controls.
Plasma transthyretin concentrations were measured by BS 200 Autoanalyser (Mindray, Shenzhen, China) using immunoturbidimetric method.

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Type 2 diabetes mellitus
Ramy czasowe: From December 2010 to December 2016
In the case-control study, type 2 diabetes mellitus was diagnosed in accordance with the diagnostic criteria recommended by WHO in 1999.
From December 2010 to December 2016

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Sponsor

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Rzeczywisty)

1 grudnia 2010

Zakończenie podstawowe (Rzeczywisty)

31 grudnia 2016

Ukończenie studiów (Rzeczywisty)

30 czerwca 2020

Daty rejestracji na studia

Pierwszy przesłany

7 maja 2022

Pierwszy przesłany, który spełnia kryteria kontroli jakości

7 maja 2022

Pierwszy wysłany (Rzeczywisty)

11 maja 2022

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

11 maja 2022

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

7 maja 2022

Ostatnia weryfikacja

1 maja 2022

Więcej informacji

Terminy związane z tym badaniem

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Subskrybuj