Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

Application of CT-Linac-Based "All-in-One" One-Stop Radiotherapy in Breast Cancer

19 sierpnia 2026 zaktualizowane przez: Xiaoli Yu, Fudan University

Application of CT-Linac-Based "All-in-One" One-Stop Radiotherapy in All-Scenario Breast Cancer Radiotherapy: A Prospective Clinical Study

This study aims to evaluate and report the clinical adverse events and dosimetric parameters in breast cancer patients undergoing an "all-in-one (AIO)" one-stop, fully automated radiotherapy workflow. By systematically tracking these clinical and physical metrics, we seek to establish a standardized clinical protocol for AIO radiotherapy in breast cancer management.

Przegląd badań

Status

Rekrutacyjny

Warunki

Interwencja / Leczenie

Typ studiów

Interwencyjne

Zapisy (Szacowany)

225

Faza

  • Nie dotyczy

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Kontakt w sprawie studiów

Kopia zapasowa kontaktu do badania

Lokalizacje studiów

    • Shanghai Municipality
      • Shanghai, Shanghai Municipality, Chiny, 200032
        • Rekrutacyjny
        • Fudan University Shanghai Cancer Center
        • Kontakt:

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

  • Dorosły
  • Starszy dorosły

Akceptuje zdrowych ochotników

Nie

Opis

Inclusion Criteria:

  • Histologically or pathologically confirmed breast cancer with definitive indications for radiotherapy (preoperative, postoperative, or radical)
  • ECOG performance status of 0-2
  • Able to remain still and supine on the treatment couch for up to 30 minutes
  • Provision of signed, written informed consent
  • Able to comply with daily follow-ups and blood sample collections

Exclusion Criteria:

  • Palliative radiotherapy for concurrent distant metastasis
  • Incomplete or ongoing chemotherapy
  • Synchronous multiple primary tumors
  • Current pregnancy or lactation
  • Prior history of radiotherapy to the ipsilateral breast, chest wall, thorax, or regional lymph nodes
  • Severe non-malignant comorbidities (e.g., cardiovascular or pulmonary diseases, systemic lupus erythematosus, scleroderma) resulting in a short life expectancy or inability to tolerate radical radiotherapy
  • Inability or unlikelihood to comply with study follow-up
  • Inability or unwillingness to provide written informed consent

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Inny
  • Przydział: Nielosowe
  • Model interwencyjny: Zadanie sekwencyjne
  • Maskowanie: Brak (otwarta etykieta)

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Inny: ARM1: AI-empowered AIO WBI
Evaluates the feasibility, safety, and patient experiences of the AI-empowered AIO workflow in breast cancer patients undergoing whole-breast irradiation (WBI) without regional nodal involvement.
The workflow relies on specialized convolutional neural networks for automated segmentation and dose-prediction auto-planning. These breast cancer models were trained on 285 historical institutional cases spanning radical mastectomy and breast-conserving surgery over five years. Auto-delineated structures include the clinical target volume, regional lymph nodes (if involved), tumor bed (identified by surgical clips), heart, bilateral lungs, unaffected breast, spinal cord, esophagus, thyroid, and affected humeral head. These contours guide dose prediction to generate deliverable tangential arc plans via clinical-goal-guided automated optimization in the treatment planning system. To adapt to the on-couch treatment scenario, models were validated on retrospective data and offline routines to maximize target delineation accuracy and the first-approval rate of auto-plans.
Inny: ARM2: Expanded-Scenario AIO RT
Evaluates the feasibility, safety, and patient experiences of the AI-empowered AIO workflow in breast cancer patients with broader radiotherapy indications, including breast/chest wall irradiation with or without regional nodal radiotherapy.
The workflow relies on specialized convolutional neural networks for automated segmentation and dose-prediction auto-planning. These breast cancer models were trained on 285 historical institutional cases spanning radical mastectomy and breast-conserving surgery over five years. Auto-delineated structures include the clinical target volume, regional lymph nodes (if involved), tumor bed (identified by surgical clips), heart, bilateral lungs, unaffected breast, spinal cord, esophagus, thyroid, and affected humeral head. These contours guide dose prediction to generate deliverable tangential arc plans via clinical-goal-guided automated optimization in the treatment planning system. To adapt to the on-couch treatment scenario, models were validated on retrospective data and offline routines to maximize target delineation accuracy and the first-approval rate of auto-plans.

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
Acute adverse events
Ramy czasowe: 6 months
The incidence and severity of acute adverse event include radiation dermatitis, pruritus, skin pain, radiation esophagitis, and radiation pneumonitis.
6 months

Miary wyników drugorzędnych

Miara wyniku
Opis środka
Ramy czasowe
Accuracy
Ramy czasowe: 2 months
Auto-segmentation accuracy was assessed by comparing automatically generated contours against the final physician-approved contours
2 months
Success rate
Ramy czasowe: 2 months
Record AIO workflow success rate: online planning one-pass optimization success rate.
2 months
Quality of life (QoL)
Ramy czasowe: 6 months
Quality of life will be evaluated via standardized QoL scales.
6 months
Time efficiency
Ramy czasowe: 2 months
The time efficiency of the workflow was automatically recorded by the system
2 months
Full-Workflow Patient Intrafraction Motion
Ramy czasowe: 2 months
Evaluated based on geometric deviations between pretreatment image-guided radiotherapy (IGRT), posttreatment imaging, and the baseline simulation CT
2 months
Correlation of Patient Metrology with Setup Error and Dosimetric Performance
Ramy czasowe: 2 months
Evaluation of how Body Mass Index (BMI) and weight fluctuations correlate with geometric setup errors and in vivo gamma pass rates
2 months
Correlation of Anatomical Scale with Setup Error and Dosimetric Performance
Ramy czasowe: 2 months
Evaluation of how anatomical scale/breast size correlates with geometric setup errors and in vivo gamma pass rates
2 months

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Rzeczywisty)

27 sierpnia 2021

Zakończenie podstawowe (Szacowany)

27 sierpnia 2028

Ukończenie studiów (Szacowany)

27 listopada 2028

Daty rejestracji na studia

Pierwszy przesłany

1 lipca 2026

Pierwszy przesłany, który spełnia kryteria kontroli jakości

19 sierpnia 2026

Pierwszy wysłany (Rzeczywisty)

20 sierpnia 2026

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

20 sierpnia 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

19 sierpnia 2026

Ostatnia weryfikacja

1 czerwca 2026

Więcej informacji

Terminy związane z tym badaniem

Inne numery identyfikacyjne badania

  • FDRT-BC029

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

TAK

Typ informacji pomocniczych dotyczących udostępniania IPD

  • PROTOKÓŁ BADANIA
  • ICF

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Subskrybuj