Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Investigating the Effects of Evening Light Exposure on Melatonin Suppression, Alertness and Nocturnal Sleep

10 de setembro de 2021 atualizado por: Steven W. Lockley, Brigham and Women's Hospital

Investigating the Effects of Evening Light Exposure on Melatonin Suppression, Alertness and Nocturnal Sleep.

The timing and quality of sleep is governed by environmental and physiologic factors. Environmental factors, especially ambient lighting can impact the circadian system and alter the timing and structure of sleep. Light exposure can also acutely alter neural activation state and impair sleep. These effects all demonstrate marked sensitivity to short-wavelength blue light with maximal sensitivity in the 460-480 nm range. The alerting effects of blue light in the evening persist for at least 3-4 hours after the lights are turned off, and can disturb subsequent sleep. Avoiding these deleterious effects of light exposure prior to sleep on subsequent sleep would be beneficial to sleep quality and potentially health.

The investigators will compare the effects of two light sources, equated for visual stimulus (lux), on multiple non-visual responses to light. The investigators will compare a 90 lux exposure of a commercially available Compact Fluorescent Light (CFL) with a novel LED white light source that is depleted in the short-wavelength visible range (Biological Illumination LCC, FL). In a within-subject design, the investigators will test the hypotheses that exposure to a blue-depleted LED as compared to a CFL exposure at (1) 90 lux or (2) 50 lux will cause significantly:

  1. Less melatonin suppression between melatonin onset and bedtime;
  2. Less subjective and objective alerting responses before bedtime;
  3. Less disruption of nocturnal sleep structure and quality.

Visão geral do estudo

Status

Concluído

Intervenção / Tratamento

Tipo de estudo

Intervencional

Inscrição (Real)

33

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

    • Massachusetts
      • Boston, Massachusetts, Estados Unidos, 02115
        • Brigham and Women's Hospital

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

18 anos a 30 anos (Adulto)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Tudo

Descrição

Inclusion Criteria:

(i) Aged between 18-30 years to reduce the confounding effects of lens aging on the transmission of light to the retina;

(ii) Non-smoking for at least 6 months;

(iii) Healthy (no medical, psychiatric or sleep disorders);

(iv) No clinically significant deviations from normal in medical history, vital signs, physical examination, blood chemistry and hematology, urine chemistry and ECG;

(v) Women of childbearing potential must agree to use an acceptable method of birth control, and must have a negative urine pregnancy test;

(vi) Body mass index of > 18 or < 30 kg/m2;

(vii) No drugs or medication likely to affect sleep or alertness, as determined by the investigators;

(viii) Habitual caffeine consumption < 300mg per day on average;

(ix) Habitual alcohol consumption < 10 alcoholic units per week on average.

Exclusion Criteria:

(i) History of alcohol or substance abuse;

(ii) Positive result on drugs of abuse screening;

(iii) Current or past history of sleep disorders, including but not limited to obstructive sleep apnea, or any significant sleep complaint;

(iv) Psychiatric disorder;

(v) Recent acute or chronic medical disorder, including but not limited to hepatic impairment and severe chronic obstructive pulmonary disease;

(vi) Visual disorder, including but not limited to color blindness, or family history of glaucoma;

(vii) History of intolerance or hypersensitivity to melatonin or melatonin agonists;

(viii) Pregnancy or lactation;

(ix) Shift work;

(x) Transmeridian travel (2 or more time zones) in past 2 months;

(xi) Any other reason as determined by the Principal Investigator.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Ciência básica
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição fatorial
  • Mascaramento: Solteiro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Comparador Ativo: Compact Fluorescent Light 90 lux
90 lux exposure of a commercially available Compact Fluorescent Light (CFL).
We will compare the effects of two light sources, equated for visual stimulus (lux), on multiple non-visual responses to light including melatonin suppression before bedtime. We will compare a 90 lux exposure of a commercially available Compact Fluorescent Light (CFL) with a novel LED white light source that is depleted in the short-wavelength visible range (Biological Illumination LCC, FL).
Experimental: Blue-depleted LED light 90 lux
90 lux exposure of a novel LED white light source that is depleted in the short-wavelength visible range (Biological Illumination LCC, FL).
We will compare the effects of two light sources, equated for visual stimulus (lux), on multiple non-visual responses to light including melatonin suppression before bedtime. We will compare a 90 lux exposure of a commercially available Compact Fluorescent Light (CFL) with a novel LED white light source that is depleted in the short-wavelength visible range (Biological Illumination LCC, FL).
Comparador Ativo: Compact Fluorescent Light 50 lux
50 lux exposure of a commercially available Compact Fluorescent Light (CFL).
We will compare the effects of two light sources, equated for visual stimulus (lux), on multiple non-visual responses to light including melatonin suppression before bedtime. We will compare a 90 lux exposure of a commercially available Compact Fluorescent Light (CFL) with a novel LED white light source that is depleted in the short-wavelength visible range (Biological Illumination LCC, FL).
Experimental: Blue-depleted LED light 50 lux
50 lux exposure of a novel LED white light source that is depleted in the short-wavelength visible range (Biological Illumination LCC, FL).
We will compare the effects of two light sources, equated for visual stimulus (lux), on multiple non-visual responses to light including melatonin suppression before bedtime. We will compare a 90 lux exposure of a commercially available Compact Fluorescent Light (CFL) with a novel LED white light source that is depleted in the short-wavelength visible range (Biological Illumination LCC, FL).

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Melatonin Suppression
Prazo: 6-h constant posture interval of the light exposure
Melatonin suppression is measured as the percentage of melatonin AUC relative to the AUC measured in dim light on the previous day. AUC was calculated during the 6 h of light exposure and the corresponding 6-h interval 24 hours earlier. Higher values indicate more light-induced melatonin suppression.
6-h constant posture interval of the light exposure

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
Sleep Structure
Prazo: 8-h time in bed immediately following CFL/LED light exposure.
Sleep efficiency assessed by polysomnography. Sleep efficiency refers to the percentage of time a person sleeps, in relation to the amount of time a person spends in bed trying to sleep. The percentage is calculated by dividing the Total Sleep Time by the Total Time in Bed.
8-h time in bed immediately following CFL/LED light exposure.
Sleep Quality
Prazo: First morning after 8-h time in bed immediately following CFL/LED light exposure.
Self-reported sleep quality was assessed using a post sleep questionnaire. Score on subjective scale range 1-7, higher scores indicate higher sleep quality.
First morning after 8-h time in bed immediately following CFL/LED light exposure.
Subjective Alerting Response
Prazo: 6-h constant posture interval of the light exposure.
Self-reported sleepiness measured during the light exposure using the Karolinska Sleepiness Scale (KSS). Range of scores 1-9, higher score indicate higher subjective sleepiness. Measures were taken hourly throughout the 6-hour constant posture interval of the light exposure and then averaged to calculate a single value per participant.
6-h constant posture interval of the light exposure.
Objective Alerting Response
Prazo: 6-h constant posture interval of the light exposure
Mean reaction time assessed using the 10-minute psychomotor vigilance test. Higher numbers indicate slower reaction times indicating less alertness. Measures were taken hourly throughout the 6-hour constant posture interval of the light exposure and then averaged to calculate a single value per participant.
6-h constant posture interval of the light exposure

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Investigadores

  • Investigador principal: Steven W Lockley, Ph.D., Brigham and Women's Hospital; Harvard Medical School

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo

1 de agosto de 2012

Conclusão Primária (Real)

1 de março de 2014

Conclusão do estudo (Real)

1 de março de 2014

Datas de inscrição no estudo

Enviado pela primeira vez

24 de abril de 2012

Enviado pela primeira vez que atendeu aos critérios de CQ

25 de abril de 2012

Primeira postagem (Estimativa)

26 de abril de 2012

Atualizações de registro de estudo

Última Atualização Postada (Real)

14 de setembro de 2021

Última atualização enviada que atendeu aos critérios de controle de qualidade

10 de setembro de 2021

Última verificação

1 de setembro de 2021

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • 2011-P-002834

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

produto fabricado e exportado dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever