- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT03220217
To Evaluate the Optimal Dose of 68Ga-OPS202 as a PET (Positron Emission Tomography) Imaging Agent in Subjects With Gastroenteropancreatic Neuroendocrine Tumour (GEP-NET)
8 de janeiro de 2021 atualizado por: Ipsen
A Multicentre, Randomised, Dose-confirmation, Factorial Phase II Study to Evaluate the Optimal Dose of 68Ga-OPS202 as a PET Imaging Agent in Subjects With Gastroenteropancreatic Neuroendocrine Tumour (GEP-NET)
The purpose of this clinical research is to confirm the optimal dose of 68Ga-satoreotide trizoxetan (68Ga-IPN01070), formerly 68Ga-OPS202, as a PET imaging agent to be used to detect and localize gastro-entero-pancreatic neuroendocrine tumors (GEP-NETs).
68Ga-IPN01070 is a radiolabelled imaging agent to be used in association with Positron-Emission-Tomography (PET).
68Ga-IPN01070 is made of two main components: 1) IPN01070, an antagonistic somatostatin analogue which binds to the somatostatin receptor (type 2) present on the surface of the tumor cells and 2) Gallium-68, a radioisotope that combined with IPN01070 can be seen in the PET scanner.
Visão geral do estudo
Status
Concluído
Intervenção / Tratamento
Tipo de estudo
Intervencional
Inscrição (Real)
29
Estágio
- Fase 2
Contactos e Locais
Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.
Locais de estudo
-
-
-
Aarhus, Dinamarca, DK-8000
- Aarhus University Hospital
-
Copenhagen, Dinamarca, DK-2100
- Rigshospitalet, University of Copenhagen
-
-
-
-
California
-
Los Angeles, California, Estados Unidos, 90095
- UCLA Medical Center
-
-
-
-
-
Innsbruck, Áustria, A-6020
- Medical University of Innsbruck
-
Vienna, Áustria, A-1090
- University Clinic for Radiology and Nuclear Medicine
-
-
Critérios de participação
Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.
Critérios de elegibilidade
Idades elegíveis para estudo
18 anos e mais velhos (Adulto, Adulto mais velho)
Aceita Voluntários Saudáveis
Não
Gêneros Elegíveis para o Estudo
Tudo
Descrição
Inclusion Criteria:
- Pathologically confirmed, well differentiated functioning or non-functioning metastatic GEP-NET (Grade I and II as per World Health Organisation classification 2010)
- Confirmed presence of somatostatin receptors (type 2) on technically evaluable tumour lesions documented by a positive Somatostatin Receptor Scan acquired within 6 months prior to screening (Visit 1) and showing minimally two lesions in at least one of the key organs; these images shall be available to be sent to the imaging core lab electronically to ascertain quality and admissibility
- Body weight between 50 kg (110 lb) and 110 kg (243 lb), inclusive
- Adequate bone marrow, liver and renal function
- Eastern Cooperative Oncology Group (ECOG) performance status ≤2
Exclusion Criteria:
- Fewer than five lesions in total and more than 25 lesions/organ detected by the previous somatostatin receptor scan in key organs: liver, lymph nodes, bone or lungs
- Subject who have received treatment of any somatostatin analogue, including Somatuline® Autogel® /Depot®, Sandostatin® LAR within 28 days, and Sandostatin® within 24 hours prior to first 68Ga-OPS202 administration
- Prior or planned administration of a radiopharmaceutical within 8 half-lives of the radionuclide
- Any condition that precludes the proper performance of PET and/or CT scan: a) Subjects who are not able to tolerate the CT contrast agent, b) Subjects with metal implants or arthroplasty, or any other objects that might interfere with the PET and/or CT analysis, c) Subjects unable to raise arms for prolonged imaging purposes, d) Subjects unable to lie still for the entire imaging time, e) Subjects weighing greater than 110 kg (243 lb)
Plano de estudo
Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Diagnóstico
- Alocação: Randomizado
- Modelo Intervencional: Atribuição fatorial
- Mascaramento: Solteiro
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: 5-20μg/40-80 MBq, 30-45μg/100-140 MBq
Subjects will receive a first intravenous (i.v.) injection of satoreotide trizoxetan with a peptide mass dose range of 5 to 20 μg and a radioactivity dose range 40 to 80 MBq.
After 15 to 21 days the subjects will receive a second i.v.
injection of satoreotide trizoxetan with a peptide mass dose range of 30-45 μg and a radioactivity dose range 100 to 140 MBq.
|
Positron emission tomography (PET) imaging agent
Outros nomes:
Positron emission tomography (PET) imaging agent
Outros nomes:
|
|
Experimental: 5-20μg/100-140 MBq, 30-45μg/160-200 MBq
Subjects will receive a first i.v.
injection of satoreotide trizoxetan with a peptide mass dose range of 5 to 20 μg and a radioactivity dose range 100 to 140 MBq.
After 15 to 21 days the subjects will receive a second i.v.
injection of satoreotide trizoxetan with a peptide mass dose range of 30-45 μg and a radioactivity dose range 160 to 200 MBq.
|
Positron emission tomography (PET) imaging agent
Outros nomes:
Positron emission tomography (PET) imaging agent
Outros nomes:
|
|
Experimental: 5-20μg/160-200 MBq, 30-45μg/40-80 MBq
Subjects will receive a first i.v.
injection of satoreotide trizoxetan with a peptide mass dose range of 5 to 20 μg and a radioactivity dose range 160 to 200 MBq.
After 15 to 21 days the subjects will receive a second i.v.
injection of satoreotide trizoxetan with a peptide mass dose range of 30-45 μg and a radioactivity dose range 40 to 80 MBq.
|
Positron emission tomography (PET) imaging agent
Outros nomes:
Positron emission tomography (PET) imaging agent
Outros nomes:
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Relative Lesion Counts Presented by Combination of Injected Peptide/Radioactivity Dose Ranges
Prazo: Day 1 and Days 16 to 22
|
For each combination of injected peptide/radioactivity dose range, relative lesion counts were measured as the ratio of the number of lesions detected by 68Ga-satoreotide trizoxetan PET/CT and PET readings to the number of lesions assessed by standard-of-truth (SoT).
The SoT in this study was the contrast enhanced (ce)CT scan images acquired at Visit 2 (Day 1) and Visit 3 (Days 16 to 22).
Relative lesion counts for PET/CT and PET readings are presented for all organs, primary site of GEP-NET and per organ by each combination of injected peptide/radioactivity dose range after the 1st and 2nd injections.
|
Day 1 and Days 16 to 22
|
|
Relative Lesion Counts Presented by Peptide Mass and Radioactivity Dose Ranges
Prazo: Day 1 and Days 16 to 22
|
For each combination of injected peptide/radioactivity dose range, relative lesion counts were measured as the ratio of the number of lesions detected by 68Ga-satoreotide trizoxetan PET/CT and PET readings to the number of lesions assessed by SoT.
The SoT in this study was the ceCT scan images acquired at Visit 2 (Day 1) and Visit 3 (Day 16 to 22).
Relative lesion counts for PET/CT and PET readings are presented for all organs, primary site of GEP-NET and per organ by both peptide mass range and radioactivity dose range.
|
Day 1 and Days 16 to 22
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Image Quality as Assessed by Tumour-To-Background Ratio Presented by Combination of Injected Peptide/Radioactivity Dose Range
Prazo: Day 1 and Days 16 to 22
|
For each PET assessment, image quality was quantitatively measured by the tumour-to-background ratio, obtained using the mean of all lesions tumour-to-backgrounds, for each of the following organs; liver, lymph nodes, bone and lungs.
The tumour-to-background ratio was computed by mean standardised uptake value (SUVmean) of the lesion divided by the SUVmean of the subject's reference tissue (tumour-free liver or aortic blood).
A high tumour-to-background ratio indicates high effectiveness of 68Ga-satoreotide trizoxetan as a diagnostic agent.
Tumour-to-background ratios are presented for primary site of GEP-NET and per organ by each combination of injected peptide/radioactivity dose range.
|
Day 1 and Days 16 to 22
|
|
Image Quality as Assessed by Tumour-To-Background Ratio Presented by Peptide Mass and Radioactivity Dose Ranges
Prazo: Day 1 and Days 16 to 22
|
For each PET assessment image quality was quantitatively measured by the tumour-to-background ratio, obtained using the mean of all lesions tumour-to-backgrounds, for each of the following organs; liver, lymph nodes, bone and lungs.
The tumour-to-background ratio was computed by SUVmean of the lesion divided by the SUVmean of the subject's reference tissue (tumour-free liver or aortic blood).
A high tumour-to-background ratio indicates high effectiveness of 68Ga-satoreotide trizoxetan as a diagnostic agent.
Tumour-to-background ratios are presented for primary site of GEP-NET and per organ by both peptide mass range and radioactivity dose range.
|
Day 1 and Days 16 to 22
|
|
Image Quality as Assessed by Independent Blinded Readers Quality Score
Prazo: Day 1 and Days 16 to 22
|
A qualitative analysis of the image was assessed by 2 independent blinded readers using a quality score (performed as a back-up to the quantitative quality measured by tumour-to-background analysis).
For each PET/CT and PET assessment, each reader performed a direct comparison of the 2 scans from Visit 2 and Visit 3.
They noted which scan provided superior images based on overall image quality and lesion count and attributed a score for each assessment.
The score for the assessment having superior images was set to "1", and score for the assessment not selected was set to "0".
In case of equal quality, both assessments had a score of "1".
The image quality score for PET/CT and PET readings as cumulative sum of readers' scores across all subjects by peptide mass and radioactivity dose range combination is presented.
Score ranges from 0-16 with higher score indicating more assessments classed as superior.
|
Day 1 and Days 16 to 22
|
|
Lesion Maximum Standardised Uptake Value (SUVmax) Presented by Combination of Injected Peptide/Radioactivity Dose Ranges
Prazo: Day 1 and Days 16 to 22
|
For each PET assessment, SUVmax was measured for each lesion, up to a maximum of 5 most avid lesions per organ that were confirmed by SoT assessment.
In order to obtain a unique measure per organ, values of the SUVmax were computed within each of the following organs; liver, lymph nodes, bone and lungs.
SUVmax results are presented for primary site of GEP-NET and per organ by each combination of injected peptide/radioactivity dose range.
|
Day 1 and Days 16 to 22
|
|
Lesion SUVmax Presented by Peptide Mass and Radioactivity Dose Ranges
Prazo: Day 1 and Days 16 to 22
|
For each PET assessment, SUVmax was measured for each lesion, up to a maximum of 5 most avid lesions per organ that are confirmed by SoT assessment.
In order to obtain a unique measure per organ, mean of the SUVmax was computed within each of the liver, lymph nodes, bone and lungs.
SUVmax results are presented for primary site of GEP-NET and per organ by both peptide mass range and radioactivity dose range.
|
Day 1 and Days 16 to 22
|
|
Absolute Number of Lesions Detected by 68Ga-Satoreotide Trizoxetan Presented by Combination of Injected Peptide/Radioactivity Dose Range
Prazo: Day 1 and Days 16 to 22
|
For each PET/CT and PET assessment, the absolute number of lesions detected by 68Ga-satoreotide trizoxetan were reported for each of the following anatomic sites; primary site of GEP-NET, liver, lymph nodes, axial/appendicular skeleton (bone) and lungs.
The absolute number of lesions for PET/CT and PET readings for the 5 anatomic sites are presented by each combination of injected peptide/radioactivity dose range.
|
Day 1 and Days 16 to 22
|
|
Absolute Number of Lesions Detected by 68Ga-Satoreotide Trizoxetan Presented by Peptide Mass and Radioactivity Dose Ranges
Prazo: Day 1 and Days 16 to 22
|
For each PET/CT and PET assessment, the absolute number of lesions detected by 68Ga-satoreotide trizoxetan were reported for each of the following anatomic sites; primary site of GEP-NET, lymph nodes, liver, axial/appendicular skeleton (bone) and lungs.
The absolute number of lesions for PET/CT and PET readings for the 5 anatomic sites are presented by both peptide mass range and radioactivity dose range.
|
Day 1 and Days 16 to 22
|
|
Difference in Number of Lesions Detected by 68Ga-Satoreotide Trizoxetan Compared to Lesions Detected by SoT Presented by Combination of Injected Peptide/Radioactivity Dose Range
Prazo: Day 1 and Days 16 to 22
|
For each PET/CT and PET assessment, the number of lesions detected by 68Ga-satoreotide trizoxetan and SoT (ceCT) were reported for each of the following anatomic sites; primary site of GEP-NET, lymph nodes, liver, axial/appendicular skeleton (bone) and lungs.
The difference was calculated by number of lesions detected by 68Ga-satoreotide trizoxetan - number of lesions detected by ceCT scan.
A positive difference indicates that more lesions were detected by 68Ga-satoreotide trizoxetan than by ceCT scan.
A negative difference indicates that more lesions were detected by ceCT scan than by 68Ga-satoreotide trizoxetan.
The difference in number of lesions for PET/CT and PET readings for the 5 anatomic sites are presented by each combination of injected peptide/radioactivity dose range.
|
Day 1 and Days 16 to 22
|
|
Difference in Number of Lesions Detected by 68Ga-Satoreotide Trizoxetan Compared to Lesions Detected by SoT Presented by Peptide Mass and Radioactivity Dose Ranges
Prazo: Day 1 and Days 16 to 22
|
For each PET/CT and PET assessment, the number of lesions detected by 68Ga-satoreotide trizoxetan and SoT (ceCT) were reported for each of the following anatomic sites; primary site of GEP-NET, lymph nodes, liver, axial/appendicular skeleton (bone) and lungs.
The difference was calculated by number of lesions detected by 68Ga-satoreotide trizoxetan - number of lesions detected by ceCT scan.
A positive difference indicates that more lesions were detected by 68Ga-satoreotide trizoxetan than by ceCT scan.
A negative difference indicates that more lesions were detected by ceCT scan than by 68Ga-satoreotide trizoxetan.
The difference in number of lesions for PET/CT and PET readings for the 5 anatomic sites results are presented by both peptide mass range and radioactivity dose range.
|
Day 1 and Days 16 to 22
|
Colaboradores e Investigadores
É aqui que você encontrará pessoas e organizações envolvidas com este estudo.
Patrocinador
Publicações e links úteis
A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.
Datas de registro do estudo
Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.
Datas Principais do Estudo
Início do estudo (Real)
26 de setembro de 2017
Conclusão Primária (Real)
25 de julho de 2019
Conclusão do estudo (Real)
5 de agosto de 2019
Datas de inscrição no estudo
Enviado pela primeira vez
26 de junho de 2017
Enviado pela primeira vez que atendeu aos critérios de CQ
13 de julho de 2017
Primeira postagem (Real)
18 de julho de 2017
Atualizações de registro de estudo
Última Atualização Postada (Real)
14 de janeiro de 2021
Última atualização enviada que atendeu aos critérios de controle de qualidade
8 de janeiro de 2021
Última verificação
1 de janeiro de 2021
Mais Informações
Termos relacionados a este estudo
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- D-FR-01070-002
- 2016-004928-39 (Número EudraCT)
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Sim
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Não
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .
Ensaios clínicos em Satoreotide trizoxetan 5-20μg
-
Intron Biotechnology, Inc.ConcluídoSíndrome de Radiação AgudaRepublica da Coréia