- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT03220217
To Evaluate the Optimal Dose of 68Ga-OPS202 as a PET (Positron Emission Tomography) Imaging Agent in Subjects With Gastroenteropancreatic Neuroendocrine Tumour (GEP-NET)
8 de enero de 2021 actualizado por: Ipsen
A Multicentre, Randomised, Dose-confirmation, Factorial Phase II Study to Evaluate the Optimal Dose of 68Ga-OPS202 as a PET Imaging Agent in Subjects With Gastroenteropancreatic Neuroendocrine Tumour (GEP-NET)
The purpose of this clinical research is to confirm the optimal dose of 68Ga-satoreotide trizoxetan (68Ga-IPN01070), formerly 68Ga-OPS202, as a PET imaging agent to be used to detect and localize gastro-entero-pancreatic neuroendocrine tumors (GEP-NETs).
68Ga-IPN01070 is a radiolabelled imaging agent to be used in association with Positron-Emission-Tomography (PET).
68Ga-IPN01070 is made of two main components: 1) IPN01070, an antagonistic somatostatin analogue which binds to the somatostatin receptor (type 2) present on the surface of the tumor cells and 2) Gallium-68, a radioisotope that combined with IPN01070 can be seen in the PET scanner.
Descripción general del estudio
Estado
Terminado
Condiciones
Intervención / Tratamiento
Tipo de estudio
Intervencionista
Inscripción (Actual)
29
Fase
- Fase 2
Contactos y Ubicaciones
Esta sección proporciona los datos de contacto de quienes realizan el estudio e información sobre dónde se lleva a cabo este estudio.
Ubicaciones de estudio
-
-
-
Innsbruck, Austria, A-6020
- Medical University of Innsbruck
-
Vienna, Austria, A-1090
- University Clinic for Radiology and Nuclear Medicine
-
-
-
-
-
Aarhus, Dinamarca, Dk-8000
- Aarhus University Hospital
-
Copenhagen, Dinamarca, DK-2100
- Rigshospitalet, University of Copenhagen
-
-
-
-
California
-
Los Angeles, California, Estados Unidos, 90095
- UCLA Medical Center
-
-
Criterios de participación
Los investigadores buscan personas que se ajusten a una determinada descripción, denominada criterio de elegibilidad. Algunos ejemplos de estos criterios son el estado de salud general de una persona o tratamientos previos.
Criterio de elegibilidad
Edades elegibles para estudiar
18 años y mayores (Adulto, Adulto Mayor)
Acepta Voluntarios Saludables
No
Géneros elegibles para el estudio
Todos
Descripción
Inclusion Criteria:
- Pathologically confirmed, well differentiated functioning or non-functioning metastatic GEP-NET (Grade I and II as per World Health Organisation classification 2010)
- Confirmed presence of somatostatin receptors (type 2) on technically evaluable tumour lesions documented by a positive Somatostatin Receptor Scan acquired within 6 months prior to screening (Visit 1) and showing minimally two lesions in at least one of the key organs; these images shall be available to be sent to the imaging core lab electronically to ascertain quality and admissibility
- Body weight between 50 kg (110 lb) and 110 kg (243 lb), inclusive
- Adequate bone marrow, liver and renal function
- Eastern Cooperative Oncology Group (ECOG) performance status ≤2
Exclusion Criteria:
- Fewer than five lesions in total and more than 25 lesions/organ detected by the previous somatostatin receptor scan in key organs: liver, lymph nodes, bone or lungs
- Subject who have received treatment of any somatostatin analogue, including Somatuline® Autogel® /Depot®, Sandostatin® LAR within 28 days, and Sandostatin® within 24 hours prior to first 68Ga-OPS202 administration
- Prior or planned administration of a radiopharmaceutical within 8 half-lives of the radionuclide
- Any condition that precludes the proper performance of PET and/or CT scan: a) Subjects who are not able to tolerate the CT contrast agent, b) Subjects with metal implants or arthroplasty, or any other objects that might interfere with the PET and/or CT analysis, c) Subjects unable to raise arms for prolonged imaging purposes, d) Subjects unable to lie still for the entire imaging time, e) Subjects weighing greater than 110 kg (243 lb)
Plan de estudios
Esta sección proporciona detalles del plan de estudio, incluido cómo está diseñado el estudio y qué mide el estudio.
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Diagnóstico
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación factorial
- Enmascaramiento: Único
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
---|---|
Experimental: 5-20μg/40-80 MBq, 30-45μg/100-140 MBq
Subjects will receive a first intravenous (i.v.) injection of satoreotide trizoxetan with a peptide mass dose range of 5 to 20 μg and a radioactivity dose range 40 to 80 MBq.
After 15 to 21 days the subjects will receive a second i.v.
injection of satoreotide trizoxetan with a peptide mass dose range of 30-45 μg and a radioactivity dose range 100 to 140 MBq.
|
Positron emission tomography (PET) imaging agent
Otros nombres:
Positron emission tomography (PET) imaging agent
Otros nombres:
|
Experimental: 5-20μg/100-140 MBq, 30-45μg/160-200 MBq
Subjects will receive a first i.v.
injection of satoreotide trizoxetan with a peptide mass dose range of 5 to 20 μg and a radioactivity dose range 100 to 140 MBq.
After 15 to 21 days the subjects will receive a second i.v.
injection of satoreotide trizoxetan with a peptide mass dose range of 30-45 μg and a radioactivity dose range 160 to 200 MBq.
|
Positron emission tomography (PET) imaging agent
Otros nombres:
Positron emission tomography (PET) imaging agent
Otros nombres:
|
Experimental: 5-20μg/160-200 MBq, 30-45μg/40-80 MBq
Subjects will receive a first i.v.
injection of satoreotide trizoxetan with a peptide mass dose range of 5 to 20 μg and a radioactivity dose range 160 to 200 MBq.
After 15 to 21 days the subjects will receive a second i.v.
injection of satoreotide trizoxetan with a peptide mass dose range of 30-45 μg and a radioactivity dose range 40 to 80 MBq.
|
Positron emission tomography (PET) imaging agent
Otros nombres:
Positron emission tomography (PET) imaging agent
Otros nombres:
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
---|---|---|
Relative Lesion Counts Presented by Combination of Injected Peptide/Radioactivity Dose Ranges
Periodo de tiempo: Day 1 and Days 16 to 22
|
For each combination of injected peptide/radioactivity dose range, relative lesion counts were measured as the ratio of the number of lesions detected by 68Ga-satoreotide trizoxetan PET/CT and PET readings to the number of lesions assessed by standard-of-truth (SoT).
The SoT in this study was the contrast enhanced (ce)CT scan images acquired at Visit 2 (Day 1) and Visit 3 (Days 16 to 22).
Relative lesion counts for PET/CT and PET readings are presented for all organs, primary site of GEP-NET and per organ by each combination of injected peptide/radioactivity dose range after the 1st and 2nd injections.
|
Day 1 and Days 16 to 22
|
Relative Lesion Counts Presented by Peptide Mass and Radioactivity Dose Ranges
Periodo de tiempo: Day 1 and Days 16 to 22
|
For each combination of injected peptide/radioactivity dose range, relative lesion counts were measured as the ratio of the number of lesions detected by 68Ga-satoreotide trizoxetan PET/CT and PET readings to the number of lesions assessed by SoT.
The SoT in this study was the ceCT scan images acquired at Visit 2 (Day 1) and Visit 3 (Day 16 to 22).
Relative lesion counts for PET/CT and PET readings are presented for all organs, primary site of GEP-NET and per organ by both peptide mass range and radioactivity dose range.
|
Day 1 and Days 16 to 22
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
---|---|---|
Image Quality as Assessed by Tumour-To-Background Ratio Presented by Combination of Injected Peptide/Radioactivity Dose Range
Periodo de tiempo: Day 1 and Days 16 to 22
|
For each PET assessment, image quality was quantitatively measured by the tumour-to-background ratio, obtained using the mean of all lesions tumour-to-backgrounds, for each of the following organs; liver, lymph nodes, bone and lungs.
The tumour-to-background ratio was computed by mean standardised uptake value (SUVmean) of the lesion divided by the SUVmean of the subject's reference tissue (tumour-free liver or aortic blood).
A high tumour-to-background ratio indicates high effectiveness of 68Ga-satoreotide trizoxetan as a diagnostic agent.
Tumour-to-background ratios are presented for primary site of GEP-NET and per organ by each combination of injected peptide/radioactivity dose range.
|
Day 1 and Days 16 to 22
|
Image Quality as Assessed by Tumour-To-Background Ratio Presented by Peptide Mass and Radioactivity Dose Ranges
Periodo de tiempo: Day 1 and Days 16 to 22
|
For each PET assessment image quality was quantitatively measured by the tumour-to-background ratio, obtained using the mean of all lesions tumour-to-backgrounds, for each of the following organs; liver, lymph nodes, bone and lungs.
The tumour-to-background ratio was computed by SUVmean of the lesion divided by the SUVmean of the subject's reference tissue (tumour-free liver or aortic blood).
A high tumour-to-background ratio indicates high effectiveness of 68Ga-satoreotide trizoxetan as a diagnostic agent.
Tumour-to-background ratios are presented for primary site of GEP-NET and per organ by both peptide mass range and radioactivity dose range.
|
Day 1 and Days 16 to 22
|
Image Quality as Assessed by Independent Blinded Readers Quality Score
Periodo de tiempo: Day 1 and Days 16 to 22
|
A qualitative analysis of the image was assessed by 2 independent blinded readers using a quality score (performed as a back-up to the quantitative quality measured by tumour-to-background analysis).
For each PET/CT and PET assessment, each reader performed a direct comparison of the 2 scans from Visit 2 and Visit 3.
They noted which scan provided superior images based on overall image quality and lesion count and attributed a score for each assessment.
The score for the assessment having superior images was set to "1", and score for the assessment not selected was set to "0".
In case of equal quality, both assessments had a score of "1".
The image quality score for PET/CT and PET readings as cumulative sum of readers' scores across all subjects by peptide mass and radioactivity dose range combination is presented.
Score ranges from 0-16 with higher score indicating more assessments classed as superior.
|
Day 1 and Days 16 to 22
|
Lesion Maximum Standardised Uptake Value (SUVmax) Presented by Combination of Injected Peptide/Radioactivity Dose Ranges
Periodo de tiempo: Day 1 and Days 16 to 22
|
For each PET assessment, SUVmax was measured for each lesion, up to a maximum of 5 most avid lesions per organ that were confirmed by SoT assessment.
In order to obtain a unique measure per organ, values of the SUVmax were computed within each of the following organs; liver, lymph nodes, bone and lungs.
SUVmax results are presented for primary site of GEP-NET and per organ by each combination of injected peptide/radioactivity dose range.
|
Day 1 and Days 16 to 22
|
Lesion SUVmax Presented by Peptide Mass and Radioactivity Dose Ranges
Periodo de tiempo: Day 1 and Days 16 to 22
|
For each PET assessment, SUVmax was measured for each lesion, up to a maximum of 5 most avid lesions per organ that are confirmed by SoT assessment.
In order to obtain a unique measure per organ, mean of the SUVmax was computed within each of the liver, lymph nodes, bone and lungs.
SUVmax results are presented for primary site of GEP-NET and per organ by both peptide mass range and radioactivity dose range.
|
Day 1 and Days 16 to 22
|
Absolute Number of Lesions Detected by 68Ga-Satoreotide Trizoxetan Presented by Combination of Injected Peptide/Radioactivity Dose Range
Periodo de tiempo: Day 1 and Days 16 to 22
|
For each PET/CT and PET assessment, the absolute number of lesions detected by 68Ga-satoreotide trizoxetan were reported for each of the following anatomic sites; primary site of GEP-NET, liver, lymph nodes, axial/appendicular skeleton (bone) and lungs.
The absolute number of lesions for PET/CT and PET readings for the 5 anatomic sites are presented by each combination of injected peptide/radioactivity dose range.
|
Day 1 and Days 16 to 22
|
Absolute Number of Lesions Detected by 68Ga-Satoreotide Trizoxetan Presented by Peptide Mass and Radioactivity Dose Ranges
Periodo de tiempo: Day 1 and Days 16 to 22
|
For each PET/CT and PET assessment, the absolute number of lesions detected by 68Ga-satoreotide trizoxetan were reported for each of the following anatomic sites; primary site of GEP-NET, lymph nodes, liver, axial/appendicular skeleton (bone) and lungs.
The absolute number of lesions for PET/CT and PET readings for the 5 anatomic sites are presented by both peptide mass range and radioactivity dose range.
|
Day 1 and Days 16 to 22
|
Difference in Number of Lesions Detected by 68Ga-Satoreotide Trizoxetan Compared to Lesions Detected by SoT Presented by Combination of Injected Peptide/Radioactivity Dose Range
Periodo de tiempo: Day 1 and Days 16 to 22
|
For each PET/CT and PET assessment, the number of lesions detected by 68Ga-satoreotide trizoxetan and SoT (ceCT) were reported for each of the following anatomic sites; primary site of GEP-NET, lymph nodes, liver, axial/appendicular skeleton (bone) and lungs.
The difference was calculated by number of lesions detected by 68Ga-satoreotide trizoxetan - number of lesions detected by ceCT scan.
A positive difference indicates that more lesions were detected by 68Ga-satoreotide trizoxetan than by ceCT scan.
A negative difference indicates that more lesions were detected by ceCT scan than by 68Ga-satoreotide trizoxetan.
The difference in number of lesions for PET/CT and PET readings for the 5 anatomic sites are presented by each combination of injected peptide/radioactivity dose range.
|
Day 1 and Days 16 to 22
|
Difference in Number of Lesions Detected by 68Ga-Satoreotide Trizoxetan Compared to Lesions Detected by SoT Presented by Peptide Mass and Radioactivity Dose Ranges
Periodo de tiempo: Day 1 and Days 16 to 22
|
For each PET/CT and PET assessment, the number of lesions detected by 68Ga-satoreotide trizoxetan and SoT (ceCT) were reported for each of the following anatomic sites; primary site of GEP-NET, lymph nodes, liver, axial/appendicular skeleton (bone) and lungs.
The difference was calculated by number of lesions detected by 68Ga-satoreotide trizoxetan - number of lesions detected by ceCT scan.
A positive difference indicates that more lesions were detected by 68Ga-satoreotide trizoxetan than by ceCT scan.
A negative difference indicates that more lesions were detected by ceCT scan than by 68Ga-satoreotide trizoxetan.
The difference in number of lesions for PET/CT and PET readings for the 5 anatomic sites results are presented by both peptide mass range and radioactivity dose range.
|
Day 1 and Days 16 to 22
|
Colaboradores e Investigadores
Aquí es donde encontrará personas y organizaciones involucradas en este estudio.
Patrocinador
Publicaciones y enlaces útiles
La persona responsable de ingresar información sobre el estudio proporciona voluntariamente estas publicaciones. Estos pueden ser sobre cualquier cosa relacionada con el estudio.
Fechas de registro del estudio
Estas fechas rastrean el progreso del registro del estudio y los envíos de resultados resumidos a ClinicalTrials.gov. Los registros del estudio y los resultados informados son revisados por la Biblioteca Nacional de Medicina (NLM) para asegurarse de que cumplan con los estándares de control de calidad específicos antes de publicarlos en el sitio web público.
Fechas importantes del estudio
Inicio del estudio (Actual)
26 de septiembre de 2017
Finalización primaria (Actual)
25 de julio de 2019
Finalización del estudio (Actual)
5 de agosto de 2019
Fechas de registro del estudio
Enviado por primera vez
26 de junio de 2017
Primero enviado que cumplió con los criterios de control de calidad
13 de julio de 2017
Publicado por primera vez (Actual)
18 de julio de 2017
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
14 de enero de 2021
Última actualización enviada que cumplió con los criterios de control de calidad
8 de enero de 2021
Última verificación
1 de enero de 2021
Más información
Términos relacionados con este estudio
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- D-FR-01070-002
- 2016-004928-39 (Número EudraCT)
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Sí
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
No
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .
Ensayos clínicos sobre Satoreotide trizoxetan 5-20μg
-
Intron Biotechnology, Inc.TerminadoSíndrome de radiación agudaCorea, república de